Nicotinamide adenine dinucleotide (NAD) is a REDOX cofactor and metabolite essential for neuronal survival. Glaucoma is a common neurodegenerative disease in which neuronal levels of NAD decline. We assess the effects of nicotinamide (a precursor to NAD) on retinal ganglion cells (the affected neuron in glaucoma) in normal physiological conditions and across a range of glaucoma relevant insults including mitochondrial stress and axon degenerative insults. We demonstrate retinal ganglion cell somal, axonal, and dendritic neuroprotection by nicotinamide in rodent models which represent isolated ocular hypertensive, axon degenerative, and mitochondrial degenerative insults. We performed metabolomics enriched for small molecular weight metabolites for the retina, optic nerve, and superior colliculus which demonstrates that ocular hypertension induces widespread metabolic disruption, including consistent changes to α-ketoglutaric acid, creatine/creatinine, homocysteine, and glycerophosphocholine. This metabolic disruption is prevented by nicotinamide. Nicotinamide provides further neuroprotective effects by increasing oxidative phosphorylation, buffering and preventing metabolic stress, and increasing mitochondrial size and motility whilst simultaneously dampening action potential firing frequency. These data support continued determination of the utility of long-term nicotinamide treatment as a neuroprotective therapy for human glaucoma.
Purpose: To evaluate the precision of objective refraction measurements with six different autorefractors that have different designs and measurement principles and to compare the objective refraction values with the subjective refraction. Method: Objective refraction of 55 participants was measured using six autorefractors with different designs. The instrument features mainly varied in terms of measurement principles, inbuilt fogging, open or closed view, and handheld or stationary designs. Two repeated measurements of objective refraction were performed with each autorefractor. The objective refractions from the six autorefractors were compared with the standard subjective refraction. The repeatability limit and Bland-Altman were used to describe the precision and accuracy of each autorefractor, respectively. The analysis was done using the spherical component of the refraction and the power-vector components, spherical equivalent (M), and cylindrical vectors. Results: The repeatability of all autorefractors was within 1.00 and 0.35D for measuring the M and both cylindrical components, respectively. Inbuilt fogging was the common feature of the instruments that showed better repeatability. Compared to subjective refraction, the mean difference for sphere and M was below +0.50D, and it was close to zero for the cylindrical components. The instruments that had inbuilt fogging showed narrower limit of agreement. When combined with fogging, the open field refractors showed better precision and accuracy. Conclusions: The inbuilt fogging is the most important feature followed by the open view in determining the precision and accuracy of the autorefractor values.
Objective: To evaluate the performance of two subjective refraction measurement algorithms by comparing the refraction values, visual acuity, and the time taken by the algorithms with the standard subjective refraction (SSR). Methods: The SSR and two semi-automated algorithm-based subjective refraction (SR1 and SR2) in-built in the Vision-R 800 phoropter were performed in 68 subjects. In SR1 and SR2, the subject’s responses were recorded in the algorithm which continuously modified the spherical and cylindrical component accordingly. The main difference between SR1 and SR2 is the use of an initial fogging step in SR1. Results: The average difference and agreement limits intervals in the spherical equivalent between each refraction method were smaller than 0.25 D, and 2.00 D, respectively. For the cylindrical components, the average difference was almost zero and the agreement limits interval was less than 0.50 D. The visual acuities were not significantly different among the methods. The times taken for SR1 and SR2 were significantly shorter, and SR2 was on average was three times faster than SSR. Conclusions: The refraction values and the visual acuity obtained with the standard subjective refraction and algorithm-based methods were similar on average. The algorithm-based methods were significantly faster than the standard method.
Background: To evaluate the precision and accuracy of objective refraction measurement obtained with combinations of instrument design and technique. We also compared the performance of the instruments with subjective refraction measurements. Method and analysis: The objective refraction was measured in 71 subjects with three autorefractometers that have different designs and measurement principles (binocular with fogging, binocular without fogging, and monocular with fogging). Repeatability and reproducibility metrics were calculated for the objective refraction measurements. The agreement of the objective refraction measurements between the three instruments and the agreement with the subjective refraction measurements were evaluated. Results: All three autorefractometers had repeatability and reproducibility limits smaller than 0.70D. The smallest difference (0.10D) in the spherical equivalent was seen between the two binocular instruments. Compared with the subjective refraction, the binocular without fogging technique had the smallest mean difference in spherical equivalent (<0.20D) whereas the binocular fogging technique had the smallest limit of agreement interval (1.00D). For all comparisons, the mean difference and limit of agreement interval for the cylindrical components were lower than 0.10D and 0.75D, respectively. Conclusion: All three instruments evaluated had good repeatability and reproducibility. The binocular fogging technique provided the best agreement with subjective refraction.
19 February 2019 in Journal of the Optical Society of America A
Correction and manipulation of peripheral refractive errors are indispensable for people with central vision loss and in optical interventions for myopia control. This study investigates further enhancements of peripheral vision by compensating for monochromatic higher-order aberrations (with an adaptive optics system) and chromatic aberrations (with a narrowband green filter, 550 nm) in the 20° nasal visual field. Both high-contrast detection cutoff and contrast sensitivity improved with optical correction. This improvement was most evident for gratings oriented perpendicular to the meridian due to asymmetric optical errors. When the natural monochromatic higher-order aberrations are large, resolution of 10% contrast oblique gratings can also be improved with correction of these errors. Though peripheral vision is mainly limited by refractive errors and neural factors, higher-order aberration correction beyond conventional refractive errors can still improve peripheral vision under certain circumstances.
The impact of peripheral optical errors induced by intraocular lenses was evaluated by simulating the average phakic and pseudophakic image qualities. An adaptive optics system was used to simulate the optical errors in 20° nasal and inferior visual field in phakic subjects. Peripheral resolution acuity, contrast sensitivity and hazard detection were evaluated. Pseudophakic errors typical for monofocal designs had a negative effect on resolution acuity and contrast sensitivity and the hazard detection task also showed increased false positive and misses and a longer reaction time compared to phakic optical errors. The induced peripheral pseudophakic optical errors affect the peripheral visual performance and thereby impact functional vision.