Zhi Hang Wang

Dr. Zhi Hang Wang

Air Force Engineering University
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2023 in Construction and Building Materials
Verified
Journal Article
Closed access
ZWZhi Hang Wang
Zhi Hang Wang
EBErlei Bai
Erlei Bai
LLLei Liang
Lei Liang
YLYan Lv
Yan Lv
LQLijun Qin
Lijun Qin

30 October 2020 in Materials
Verified
Journal Article
Open access
PDF file
ZWZhi Hang Wang
Zhi Hang Wang
JXJin-Yu Xu
Jin-Yu Xu
EBEr-Lei Bai
Er-Lei Bai
LNLiang-Xue Nie
Liang-Xue Nie
The formula describing the relationship between the dielectric constant of a composite and the dielectric constants or volume rates of its components is called a dielectric model. The establishment of a cement concrete dielectric model is the basic and key technique for applying electromagnetic wave technology to concrete structure quality testing and internal damage detection. To construct the dielectric model of carbon nanofiber reinforced concrete, the carbon nanofiber reinforced concrete was measured by the transmission and reflection method for dielectric constant ε, and ε,, in the frequency range of 1.7~2.6 GHz as the fiber content was 0, 0.1%, 0.2%, 0.3% and 0.5%. Meanwhile, concrete was considered as a composite material composed of three phases, matrix (mortar), coarse aggregate (limestone gravel) and air, and the dielectric constants and volume rates of each component phase were tested. The Brown model, CRIM (Complex Refractive Index Model) model and Looyenga model commonly used in composite materials were modified based on the experimental data, suitable dielectric models of carbon nanofiber reinforced concrete were constructed, and a reliability check and error analysis of the modified models were carried out. The results showed that the goodness of fit between the calculated curves based on the three modified models and the measured curves was very high, the accuracy and applicability were very strong and the variation rule for the dielectric constant of carbon nanofiber concrete with the frequency of electromagnetic wave could be described accurately. For ε, and ε,,, the error between the dielectric constant calculated by the three modified models and the corresponding measured values was very small. For the dielectric constant ε,, the average error was maintained below 1.2%, and the minimum error was only 0.35%; for the dielectric constant ε,,, the average error was maintained below 3.55%.

3 April 2023 in Construction and Building Materials
Verified
Journal Article
Closed access
ZWZhi Hang Wang
Zhi Hang Wang
EBErlei Bai
Erlei Bai
BRBiao Ren
Biao Ren
CLChaojia Liu
Chaojia Liu
JLJunliang Liu
Junliang Liu
HHHe Huang
He Huang

5 November 2022 in Structural Concrete
Verified
Journal Article
Closed access
ZWZhi Hang Wang
Zhi Hang Wang
EBErlei Bai
Erlei Bai
HHHe Huang
He Huang
BRBiao Ren
Biao Ren

1 January 2021 in Journal of Renewable Materials
Verified
Journal Article
Open access
ZWZhi Hang Wang
Zhi Hang Wang
JXJinyu Xu
Jinyu Xu
XMXin Meng
Xin Meng
CZConigjin Zhu
Conigjin Zhu
In this paper, the specimens of polymer-cement composites after 1 d, 7 d, 15 d, and 30 d aging without aging and UV aging are subjected to fixed extension test and tensile test. By observing the mode of the composite in the fixed-elongation test, and measuring the elastic recovery rate, tensile strength, elongation at break, peak tensile strain, tensile toughness and pre-peak tensile toughness of the composite, the effects of UV aging on the bonding and the tensile properties of the composite were studied. And combining with scanning electron microscopy experiments, the micro-mechanism of the effect of ultraviolet aging on the properties of composite was analyzed. The results showed that the composite had a good bonding property, and no damage was observed after UV aging for 30 days. The UV aging increased the elastic recovery rate and peak tensile within a certain range. The elastic recovery rate and peak tensile strain of the composite increased by 6.60% and 23.55% respectively after UV aging for 15 days. Therefore, the UV aging could enhance the tensile property and the tensile energy consumption performance of the composite. The tensile strength of the composite increased by 65.36% after UV aging for 30 days. The tensile toughness and pre-peak tensile toughness of the composite were increased by 43.29% and 101.83% respectively after UV aging for 15 days. The elongation at break of composite decreased continuously after UV aging due to the photo-oxygen reaction, as well as secondary hydration reaction and cross-linking curing reaction of cement.

19 July 2022 in Materials
Verified
Journal Article
Open access
PDF file
BRBiao Ren
Biao Ren
TWTengjiao Wang
Tengjiao Wang
JXJinyu Xu
Jinyu Xu
ZWZhi Hang Wang
Zhi Hang Wang
YLYan Lv
Yan Lv
YNYipeng Ning
Yipeng Ning
Based on engineering practice and practical needs, this paper takes ordinary concrete specimens as the research object, and adopts a high-temperature true triaxial loading test system to carry out high-temperature uniaxial and true triaxial static compression tests of concrete under high-temperature conditions. By comparing with normal temperature conditions, this paper analyzes the influence of the coupling effect of high-temperature and biaxial unequal lateral pressure on the static mechanical properties of concrete. By analyzing the experimental data, we reached a series of conclusions and carried out theoretical research on this basis. High temperatures can significantly affect the uniaxial static pressure strength characteristics, deformation characteristics, and failure mode of concrete. When the temperature exceeds 400 °C, the compressive strength decreases significantly, the peak strain increases sharply, and the plasticity of concrete is further enhanced. The coupling effect of high-temperature deterioration and lateral pressure strengthening makes the true triaxial mechanical properties of concrete change significantly; 0.6:0.2 and 400 °C are the turning points of side pressure ratio and temperature that affect the change law of the true triaxial mechanical properties of concrete, respectively. Based on the study of the high-temperature deterioration factor and lateral pressure strengthening factor, this paper further puts forward a concrete strength formula under the coupling action of high temperature and biaxial unequal lateral pressure. It was verified that the formula has a high accuracy.