Based on engineering practice and practical needs, this paper takes ordinary concrete specimens as the research object, and adopts a high-temperature true triaxial loading test system to carry out high-temperature uniaxial and true triaxial static compression tests of concrete under high-temperature conditions. By comparing with normal temperature conditions, this paper analyzes the influence of the coupling effect of high-temperature and biaxial unequal lateral pressure on the static mechanical properties of concrete. By analyzing the experimental data, we reached a series of conclusions and carried out theoretical research on this basis. High temperatures can significantly affect the uniaxial static pressure strength characteristics, deformation characteristics, and failure mode of concrete. When the temperature exceeds 400 °C, the compressive strength decreases significantly, the peak strain increases sharply, and the plasticity of concrete is further enhanced. The coupling effect of high-temperature deterioration and lateral pressure strengthening makes the true triaxial mechanical properties of concrete change significantly; 0.6:0.2 and 400 °C are the turning points of side pressure ratio and temperature that affect the change law of the true triaxial mechanical properties of concrete, respectively. Based on the study of the high-temperature deterioration factor and lateral pressure strengthening factor, this paper further puts forward a concrete strength formula under the coupling action of high temperature and biaxial unequal lateral pressure. It was verified that the formula has a high accuracy.
Joint sealant is affected by various environmental factors in service, such as different temperatures, water soaking, ultraviolet and so on. In this paper, the VAE emulsion–cement compositejoint sealant was pretreated under multiple simulation environments. Thereafter, the degradation rules of fixed elongation and tensile properties of joint sealants at different mix proportions were systemically investigated under the action of external environments (temperature, water soaking and ultraviolet), and the influence mechanisms of diverse environmental factors were analyzed. The research results suggested that, under the action of external environments, the VAE emulsion–cement composite joint sealants exhibited degradation effects to varying degrees. After the addition of plasticizer, the joint sealants had reduced cohesion strength in low temperature environment and enhanced flexible deformability. The addition of water repellent improved the water resistance of joint sealants. Meanwhile, adding ultraviolet shield agent partially improved the ultraviolet radiation aging resistance. A greater powder–liquid ratio led to the lower flexibility of joint sealants, but superior water resistance and ultraviolet radiation aging resistance.