Lei Yan

Dr. Lei Yan

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2022 in Polymers
Verified
Journal Article
Open access
PDF file
LYLei Yan
Lei Yan
WDWenjie Deng
Wenjie Deng
Neng WANGNeng WANG
Neng WANG
Xuanyi XueXuanyi Xue
Xuanyi Xue
Jianmin HuaJianmin Hua
Jianmin Hua
ZCZeng-Shun Chen
Zeng-Shun Chen
Coated reinforcements are expected to improve the performance of reinforced concrete in aggressive environments, but different kinds of coated reinforcements can express a variety of properties, which can confuse researchers and engineers. This paper reviews the manufacture, corrosion mechanisms, behaviors, and applications of popular or promising coated reinforcements, incorporating galvanized reinforcements (GRs), epoxy coated reinforcements (ECRs), stainless cladding reinforcements (SCRs), and steel-fiber reinforced polymer composite bars (SFCBs). In terms of manufacture, GRs and ECRs should focus on minimizing the negative effect of manufacture on performance, while SCRs and SFCBs should reduce the cost and increase the production capacity. Behaviors of GRs and ECRs are primarily determined by the steel substrate, but the behaviors of SCRs and SFCBs are primarily affected by the coat and core, and their interaction. The corrosion mechanism of GRs and SCRs is about oxidation, while that of SFCBs is about hydrolysis. ECRs are usually corroded under film, which can be a cause of premature failure. Corrosion embrittles SCRs, as well as bare bars, but corrosion of SFCBs usually causes a reduction in maximum strength. The investigation of the corrosion behaviors of GRs and ECRs focuses on bond strength. GRs have controversial performance. ECRs have been proven to have drawbacks regarding bond strength. The use of anti-corrosion reinforcement is uneven in regions, which may correlate with the development of technology and the economy.

1 January 2018 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
LYLei Yan
Lei Yan
GWGang Wang
Gang Wang
MCMin Chen
Min Chen
KYKefeng Yue
Kefeng Yue
QLQingning Li
Qingning Li
In order to study the theory and application of the pile foundation underpinning technology, 3 local node models of underpinning structures with a similarity ratio of 1/1 were made and the progressive repeated static loading tests were conducted. The shear and antislip properties of the joint are studied, and the improved formula for calculating the shear capacity is proposed. The results show that a planting bar plays a major role in shear resistance, and the hoop rate can improve the shear capacity of the interface. The new formula for calculating the shear‐bearing capacity is proposed, and the calculation results of the formula of shear‐bearing capacity are in good agreement with the experiment results. It is completely feasible to use this formula to calculate the shear‐bearing capacity of the pile foundation underpinning structure. During the test, the bearing capacity of the model is good, which proves the reliability of the underpinning technology is good, and it can provide experimental and theoretical basis for the underpinning of similar projects.

1 December 2023 in KSCE Journal of Civil Engineering
Verified
Journal Article
Open access
PDF file
LYLei Yan
Lei Yan
XGxiaoying gou
xiaoying gou
XZXin Zhang
Xin Zhang
YJYu Jiang
Yu Jiang
XRXing-Wen Ran
Xing-Wen Ran
PZPing Zhang
Ping Zhang
To solve the issues of slippage and dislodging caused by insufficient grout compactness in railway bridge spherical steel bearings, a novel kind of anti-separation spherical steel bearing is presented. Firstly, a comparative test model was meticulously designed and constructed for the bearing-stone assembly, encompassing both the traditional spherical steel bearing and the innovative anti-separation spherical steel bearing. Next, mechanical performance testing and finite element simulation analysis were completed. Finally, an empirical equation for the vertical load-strain fitting of the bearing was established. The results demonstrate that, under the maximum vertical static load, the convex spherical crown anti-separation design of the new anti-dislodging bearing is not sensitive to the bearing performance of the bearing-bedding stone combination. All indexes also meet the specifications. Under the action of cyclic load, the error of each parameter between finite element analysis and test results is less than 7%, which shows that the new anti- separation spherical bearing has higher bearing capacity and better fatigue resistance; the fitted value of the established bearing vertical load-strain calculation formula is in agreement with the test value by more than 0.95, which can predict whether the new anti-separation bearing fails.

1 January 2020 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
ZLZhi Lin
Zhi Lin
LYLei Yan
Lei Yan
CXChen Xiang
Chen Xiang
HYHongyun Yang
Hongyun Yang
Based on the longitudinal and transverse seismic and shock absorption theory of tunnel structure, relying on the actual engineering, a finite element analysis model of a typical mountain tunnel was established. Four calculation conditions including the presence or absence of shock absorption layers and seismic joints are defined. The principal tensile (compressive) stress and displacement response of the vault, arch waist, foot of side wall, and middle of invert are studied. The results show that the shock absorption layer and the seismic joint have great influence on the dynamic response of the tunnel structure, which can reduce the main tensile (pressure) stress of different parts of the lining and change the way of stress distribution. The peak principal tensile (pressure) stress of the lining is reduced more obviously when the shock absorption layer and seismic joint are set. However, the presence of the shock absorption layer and the seismic joint will increase the peak displacement of each monitoring point of lining. The displacement of each monitoring point of lining is increased more obviously by the single shock absorption layer. Therefore, when the seismic design of the tunnel structure is carried out, the maximum seismic demand of the tunnel structure should be determined according to the specific calculation content in order to guide the design.

1 January 2021 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
LYLei Yan
Lei Yan
GLGuo Li
Guo Li
KAKang An
Kang An
KYKefeng Yue
Kefeng Yue
ZLZhi Lin
Zhi Lin
The non‐uniform stratum and uneven surface have the complicated seismic spatial variability. The seismic response of high pier and small radius curved bridge caused by the seismic specificity of this kind of terrain has not been systematically studied. According to the multi‐point excitation theory of long‐span structures and the similar theory of shaking table test in model structures, a high pier with small radius curved girder bridge was used as the research object. The shaking table test of real bridge model was carried out to study the seismic response laws of this kind of bridge under multi‐point excitation. The results show that the designed seismic wave expansion device can meet the test requirements. The frequency of the model structure decreases rapidly and the damping ratio increases during the whole test process. The local terrain effect amplifies the seismic response of high pier and small radius curved bridge. The seismic response of high pier and small radius curved bridge is affected by different frequency spectrum seismic waves, and there is a big difference. Based on the above results, the impact of multi‐point excitation should be considered in seismic design of high pier with small radius curved bridge.

6 October 2023 in Materials
Verified
Journal Article
Open access
PDF file
LYLei Yan
Lei Yan
XGxiaoying gou
xiaoying gou
ZGZhengchao Guo
Zhengchao Guo
XZXin Zhang
Xin Zhang
YJYu Jiang
Yu Jiang
KYKefeng Yue
Kefeng Yue
In view of the complexity of the pile foundation underpinning structure system and the stringent requirements of the construction process, this paper briefly describes the necessity of introducing epoxy resin reinforcing adhesive of planting rebar in the design of pile foundation underpinning beam structure to improve the mechanical properties of the reinforced beam new and old concrete joint surfaces and proposes a new type of pile foundation replacement beam system construction method by “chiseling + prestressed reinforcement + epoxy resin reinforcing adhesive”. This paper uses an actual pile foundation underpinning project of an urban overpass as a prototype, designs and creates a model structure with a similarity ratio of 1/6, and performs repeated progressive static loading tests to study the load carrying capacity, displacement change, and other properties of the strengthened replacement structure, as well as analyses and distorts the overall working performance and failure mode of them. On this basis, the prototype structure’s finite element analysis model was built, and the finite element analysis results were compared with the test results to obtain the mechanical properties and deformation characters of the actual pile foundation underpinning structure system corresponding to the actual underpinning beam load. This paper’s study can lay the theoretical and experimental foundation for the smooth development of similar projects.