Dominic A.M.J. Theuns

Dr. Dominic A.M.J. Theuns

Erasmus MC, 3000CA Rotterdam, The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2023 in European Heart Journal
Verified
Journal Article
Open access
PDF file
NSNiels Tjeerd Benjamin Scholte
Niels Tjeerd Benjamin Scholte
MGMuhammed T Gürgöze
Muhammed T Gürgöze
DADilan Aydin
Dilan Aydin
DTDominic A.M.J. Theuns
Dominic A.M.J. Theuns
OMOlivier Manintveld
Olivier Manintveld
JBJasper J. Brugts
Jasper J. Brugts
Telemonitoring modalities in heart failure (HF) have been proposed as being essential for future organization and transition of HF care, however, efficacy has not been proven. A comprehensive meta-analysis of studies on home telemonitoring systems (hTMS) in HF and the effect on clinical outcomes are provided. A systematic literature search was performed in four bibliographic databases, including randomized trials and observational studies that were published during January 1996–July 2022. A random-effects meta-analysis was carried out comparing hTMS with standard of care. All-cause mortality, first HF hospitalization, and total HF hospitalizations were evaluated as study endpoints. Sixty-five non-invasive hTMS studies and 27 invasive hTMS studies enrolled 36 549 HF patients, with a mean follow-up of 11.5 months. In patients using hTMS compared with standard of care, a significant 16% reduction in all-cause mortality was observed [pooled odds ratio (OR): 0.84, 95% confidence interval (CI): 0.77–0.93, I2: 24%], as well as a significant 19% reduction in first HF hospitalization (OR: 0.81, 95% CI 0.74–0.88, I2: 22%) and a 15% reduction in total HF hospitalizations (pooled incidence rate ratio: 0.85, 95% CI 0.76–0.96, I2: 70%). These results are an advocacy for the use of hTMS in HF patients to reduce all-cause mortality and HF-related hospitalizations. Still, the methods of hTMS remain diverse, so future research should strive to standardize modes of effective hTMS. Summary results for all-cause mortality, first heart failure hospitalization, and total/recurrent heart failure hospitalizations divided in invasive home telemonitoring systems and non-invasive home telemonitoring systems and total. I2 represents heterogeneity between studies. CI, confidence interval.

1 October 2018 in Heart Rhythm
Verified
Journal Article
Open access
DTDominic A.M.J. Theuns
Dominic A.M.J. Theuns
TBTom F. Brouwer
Tom F. Brouwer
PJPaul W. Jones
Paul W. Jones
VAVenugopal Allavatam
Venugopal Allavatam
SDSteven Donnelley
Steven Donnelley
MBMartin C. Burke
Martin C. Burke
Most inappropriate shocks from the subcutaneous implantable cardioverter-defibrillator (S-ICD) are caused by cardiac oversensing. A novel sensing methodology, SMART Pass (SP; Boston Scientific Corporation, Natick, MA), aims to reduce cardiac oversensing. The purpose of this study was to evaluate the effect of SP on shocks in ambulatory patients with S-ICD. Patients implanted in 2015-2016 and enrolled in a remote patient monitoring system were included and followed for 1 year. Shocks were adjudicated by 3 independent blinded reviewers as appropriate or inappropriate. Shock incidence was calculated for patients with SP programmed enabled or disabled at implantation, censoring patients when SP programming changed or at the last transmission. The SP setting (enabled vs disabled) was modeled as a time-dependent Cox regression variable. The cohort consisted of 1984 patients, and a total of 880 shocks were adjudicated. At implantation, SP was enabled in 655 patients (33%) and disabled in 1329 patients (67%). SP reduced the risk for the first inappropriate shock by 50% (P < .001) and the risk for all inappropriate shocks by 68% (P < .001) in multivariate analysis adjusted for age and device programming. The incidence of inappropriate shocks was 4.3% in the SP enabled arm vs 9.7% in the SP disabled arm. The incidence of appropriate shocks was similar (5.2% vs 6.6%; P = .18) along with the time to treat the first appropriate shock (17.4 seconds vs 16.7 seconds; P = .92) for SP enabled vs disabled, respectively. This prospective blinded evaluation of the SP filter demonstrates that enabling the SP filter results in a significant reduction of inappropriate shocks by the S-ICD without a negative effect on appropriate shocks.

28 January 2022 in European Heart Journal
Verified
Journal Article
Open access
PDF file
PLPier D Lambiase
Pier D Lambiase
DTDominic A.M.J. Theuns
Dominic A.M.J. Theuns
FMFrancis Murgatroyd
Francis Murgatroyd
CBCraig Barr
Craig Barr
LELars Eckardt
Lars Eckardt
LBLucas V A Boersma
Lucas V A Boersma
To report 5-year outcomes of EFFORTLESS registry patients with early generation subcutaneous implantable cardioverter-defibrillator (S-ICD) devices. Kaplan–Meier, trend and multivariable analyses were performed for mortality and late (years 2–5) complications, appropriate shock (AS) and inappropriate shock (IAS) rates. Nine hundred and eighty-four of 994 enrolled patients with diverse diagnoses (28% female, 48 ± 17 years, body mass index 27 ± 6 kg/m2, ejection fraction 43 ± 18%) underwent S-ICD implantation. Median follow-up was 5.1 years (interquartile range 4.7–5.5 years). All-cause mortality was 9.3% (95% confidence interval 7.2–11.3%) at 5 years; 703 patients remained in follow-up on study completion, 171 withdrew including 87 (8.8%) with device explanted, and 65 (6.6%) lost to follow-up. Of the explants, only 20 (2.0%) patients needed a transvenous device for pacing indications. First and final shock efficacy for discrete ventricular arrhythmias was consistent at 90% and 98%, respectively, with storm episode final shock efficacy at 95.2%. Time to therapy remained unaltered. Overall 1- and 5-year complication rates were 8.9% and 15.2%, respectively. Early complications did not predict later complications. There were no structural lead failures. Inappropriate shock rates at 1 and 5 years were 8.7% and 16.9%, respectively. Self-terminating inappropriately sensed episodes predicted late IAS. Predictors of late AS included self-terminating appropriately sensed episodes and earlier AS. In this diverse S-ICD registry population, spontaneous shock efficacy was consistently high over 5 years. Very few patients underwent S-ICD replacement with a transvenous device for pacing indications. Treated and self-terminating arrhythmic episodes predict future shock events, which should encourage more personalized device optimization. Shock efficacy of appropriate episodes experienced by patients in the EFFORTLESS study. Top left: Torso model of the implant location of the Subcutaneous Implantable Defibrillator (S-ICD) Image provided courtesy of Boston Scientific. © 2022 Boston Scientific Corporation or its affiliates. All rights reserved. Top right: Example S-ICD electrogram recording of a shock (lightning bolt icon) delivered to convert a ventricular arrhythmia. (A) Discrete episodes. (B) Storm episodes.

10 September 2010 in EP Europace
Verified
Journal Article
Open access
PDF file
DTDominic A.M.J. Theuns
Dominic A.M.J. Theuns
BSBeat A. Schaer
Beat A. Schaer
OSOsama Soliman
Osama Soliman
DADavid Altmann
David Altmann
CSChristian Sticherling
Christian Sticherling
LJLuc J.L.M. Jordaens
Luc J.L.M. Jordaens
Comorbidity, such as myocardial infarction, diabetes, and renal failure, plays a pivotal role in the prognosis of a patient with arrhythmias. However, data on the prognostic impact of comorbiditiy in heart failure patients with cardiac resynchronization therapy and defibrillation (CRT-D) are scarce. The purpose of this study was to determine the impact of comorbidity on survival in CRT-D patients. The study population consisted of 463 heart failure patients who received a CRT-D between 1999 and 2008 in Rotterdam and Basel. The Charlson comorbidity index (CCI) is often used as an adjusting variable in prognostic models. The Cox proportional hazards analysis was performed to determine the independent effect of comorbidity on survival. During a median follow-up of 30.5 months, 85 patients died. Mortality rates at 1 and 7 years were 6.3 and 32.3%. Cumulative incidence of implantable cardioverter defibrillator (ICD) therapy at 7 years was 50%, and death without ICD therapy was observed in 9% of patients. At least three comorbid conditions were observed in 81% of patients. Patients who died had a higher CCI score compared with those who survived (3.9 ± 1.5 vs. 2.9 ± 1.5; P < 0.001). An age-adjusted CCI score ≥5 was a predictor of mortality (hazard ratio 3.69, 95% CI 2.06–6.60; P < 0.001) independent from indication for ICD therapy, and from ICD interventions during the clinical course. Comorbidity is often present in heart failure patients, and a high comorbidity burden was a significant predictor of mortality in CRT-D recipients. Comorbidity cannot predict appropriate ICD therapy. Death without prior ICD therapy occurs in a minor proportion of patients.

1 December 2012 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
PDF file
DTDominic A.M.J. Theuns
Dominic A.M.J. Theuns
AEArif Elvan
Arif Elvan
WVWillem de Voogt
Willem de Voogt
CCCarel C. de Cock
Carel C. de Cock
LELieselot van Erven
Lieselot van Erven
MMMathias Meine
Mathias Meine
Background—: The Riata family of implantable cardioverter-defibrillator (ICD) leads is prone to a specific insulation abrasion characterized by externalization of conductor cables. The objective of this study was to determine the prevalence of externalized conductors and electrical abnormalities in Riata ICD leads by fluoroscopic screening and standard ICD interrogation. Methods and Results—: All ICD implantation centers were contacted by the Netherlands Heart Rhythm Association Device Advisory Committee to identify all patients with an active Riata ICD lead and to perform fluoroscopic screening of the lead. In addition, the electrical integrity of the lead was assessed. As of March 1, 2012, data for 1029 active Riata leads were available; 47% of these were 8-F Riata and 53% were 7-F Riata ST. Externalized conductors were observed in 147 leads (14.3%). Proportion of externalized conductors was higher in 8-F Riata compared with 7-F Riata ST (21.4% vs 8.0%; P <0.001). Median time from implantation to detection of externalized conductors was 65.3 months. The estimated rates of externalized conductors were 6.9% and 36.6% at 5 and 8 years after implantation, respectively. Of the 147 leads with externalized conductors, 10.9% had abnormal electrical parameters vs 3.5% in nonexternalized leads ( P <0.001). Conclusions—: The prevalence of externalized conductors in Riata leads is significantly high (14.3%) using fluoroscopic screening. The majority of externalized conductors are not detectable with standard ICD interrogation. Screening with fluoroscopy is reasonable.

6 April 2018 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
AQAnne‐Floor B. E. Quast
Anne‐Floor B. E. Quast
VDVincent F. van Dijk
Vincent F. van Dijk
SYSing‐Chien Yap
Sing‐Chien Yap
AMAlexander H. Maass
Alexander H. Maass
LBLucas V. A. Boersma
Lucas V. A. Boersma
RKReinoud E. Knops
Reinoud E. Knops