Michał Borecki

Prof. Michał Borecki

Warsaw University of Technology
+1
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MBMichał Borecki
Michał Borecki
KSKonrad Sobolewski
Konrad Sobolewski
This paper presents the possibilities of reducing emergency situations and reducing the time of failure in the power grid. The paper contains a detailed description of the method (algorithm) of operation in emergency situations on the example of a Gas-Insulated Switchgear (GIS) located in one of the system-forming (node) stations in the power grid. The level of detail contained in this paper, which has not been previously encountered in previous publications, favors an in-depth understanding of the possible solutions that result from these emergencies. The above method (algorithm) of activities has been developed based on three levels of research: simulation, theoretical and practical. This means that the simulation analysis that was performed based on theoretical information was experimentally tested as part of an emergency situation in one of the system-forming (nodal) stations in the power system. In order to achieve the result described in this article, one of the most promising types of devices used in power systems was selected - the GIS. This has been confirmed by numerous analyzes of the effectiveness of these devices included in this article. The paper contains a detailed description of the individual steps in the field of corrective actions and aimed at minimizing downtime. In addition, this article provides guidance to monitor possible emergencies that are designed to increase the reliability of the power grid.

11 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
MBMichał Borecki
Michał Borecki
Calculation models for the selection of cable lines used for expansion and modernization in the energy system and energy transmission planning are recognized tools supporting decision-making in both the energy sector and energy policy. At the same time, the above calculation models contain a large number of correction factors taking into account the temperature of the external environment at various points, the mutual influence of which is not taken into account. This means limitations to today’s common approaches to solutions, especially with regard to the required safety buffer for cable line selection. To meet this challenge, this article presents a parameter that takes into account the change and difference in temperature at various points in the external environment in the analyzed cable line systems. The purpose of this paper was to develop a new approach to the selection of a cable line in order to minimize failure during operation. For this purpose, possible temperature cases that may occur during line operation in different countries and at different rated voltages have been identified. Simulation models for individual cable line layouts were developed and the extreme temperature cases of the line operation for the maximum negative and positive temperature difference between the cable core and the external environment were considered in detail. The development of the curve of the change of the correction factor for the difference in the operating temperature of the cable line will allow for a more precise selection of the cable line parameters and the shortening of the current calculation model in terms of cable selection. In addition, this article presents a comparison of the change in the value of the correction factor from the change in temperature of a selected phase of a cable line system.

23 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
PHPiotr Hoduń
Piotr Hoduń
MBMichał Borecki
Michał Borecki
This article presents an analysis of the reliability of the power grid using data on the failure rate of the medium voltage (MV) power grid from the last five years. The analysis of the state of the power grid was based on the data provided by the grid operator. The purpose of this article is to analyze the reliability assessment of the medium voltage (MV) power connections using various analytical methods, a simulation model and reliability indicators. The analysis was performed based on the defined categories of power outages in terms of their duration. This made it possible to determine the energy quality indicators in a selected power grid. Then, a more complex analysis was carried out to assess the convergence of the applied analytical models of reliability assessment with the actual results obtained for the power grid. Moreover, using ANSYS Multiphysics, a numerical model of the cable head was developed to analyze the processes taking place in this element of the power grid for various exploitation cases.

26 January 2021 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
Verified
Journal Article
Open access
PDF file
MBMichał Borecki
Michał Borecki
MCMaciej Ciuba
Maciej Ciuba
YKYevhen Kharchenko
Yevhen Kharchenko
YKYuriy Khanas
Yuriy Khanas
The effectiveness of lightning protection on the power and distribution grid is a significant factor, which influences the power distribution reliability and the failure rate of system elements. As part of this article, a mathematical model will be presented, taking into account selected parameters that affect the assessment of the lightning hazard of an overhead line. The proposed model will consider the location of the object near the line and the adjustment of line conductor overhangs. Moreover, the mentioned mathematical model allows for analyzing the impact of considered parameters on the protection level of the power system, and transient overvoltages that occur in this system. The article contains also a detailed description of an effective and fast method to assess the lightning discharge impact on the power system with insufficient data. The introduced model was tested to verify the correctness of its operation by comparison of calculation results and functional data. High convergence of calculated and functional data and uncomplicated model structure ensure a wide range of applications for the proposed solution to easily prevent emergency situations in the power system. Furthermore, the described model gives the opportunity to assess the reduction of the range of selectivity zone associated with the power line, in conjunction with the impact of constructional peculiarities and a near object.

31 August 2020 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
Verified
Journal Article
Open access
PDF file
MBMichał Borecki
Michał Borecki
MCMaciej Ciuba
Maciej Ciuba
YKY. Kharchenko
Y. Kharchenko
YKY. Khanas
Y. Khanas
The aim of the presented work was to examine the reliability assessment model on the example of a selected power grid object. The analyzed object was tested based on assumptions about technological breaks that were caused by overvoltage, among others. The study was conducted to check the reliability of integral elements of the power grid object and to assess the change in reliability level as a function of the frequency of inspections. The test results are to determine the optimal frequency of inspections of individual power grid objects in order to increase its reliability. In addition, the possibility of correlating optimal inspection periods resulting from the findings of this paper with periodic inspections of power network facilities was assessed.

1 June 2017
Verified
Conference Paper
Closed access
MBMichał Borecki
Michał Borecki
JSJacek Starzyński
Jacek Starzyński
ZKZuzanna Krawczyk-Borysiak
Zuzanna Krawczyk-Borysiak
The aim of this article is to analyze the investment and operational costs (the costs discounted) of the medium-voltage overhead lines with covered conductors as a function of applied overvoltage protection. On the basis of a technical-economic comparative analysis of the most popular and prospective protection measures, two surge protection systems (whose use is economically justified) will be further analyzed, taking into account the design parameters of the lines with covered conductors.