This paper presents probabilistic assessment of load-bearing capacity and reliability for different STM of beams loaded with a torsional and bending moment. Three beams having different reinforcement arrangement obtained on the basis of STM but the same overall geometry and loading pattern were analysed. Stochastic modelling of this beams were performed in order to assess probabilistic load-bearing capacity. In the analysis, the random character of input data - concrete and steel was assumed. During the randomization of variables the Monte Carlo simulation with the reduce the number of simulations the Latin Hypercube Sampling (LHS) method was applied. The use of simulation methods allows for approximation of implicit response functions for complex in description and non-linear reinforced concrete structures. On the basis of the analyses and examples presented in the paper, it has been shown that the adoption of different ST models determines the different reliability of the analysed systems and elements.
The article presents comparative analyzes aimed at determining the optimal cross-section used in cold-formed steel purlins. The geometrical characteristics, bending resistance and self-weight of channel, zeta and hat cross-sections were compared. The calculations were made using Dlubal SHAPE-THIN software for the bending by the main axis y-y and z-z. The characteristics for the gross and effective cross-section were determined. Based on the first stage analyzes, a significant decrease in cross-sectional bending resistant was observed as a result of a local buckling. The solution to this problem may be the use of intermediate stiffeners. In the second stage, analysis of the impact of the intermediate stiffeners’ locations on the characteristics of hat sections were conducted. Additional intermediate stiffeners on the webs, on the upper chord, and on the webs and upper chord (together) were considered. A significant effect on the bending resistant with a small increase in the element’s self-weight has been demonstrated. In the third stage, the characteristics of a channel, zeta and hat profile with intermediate longitudinal stiffener in the middle of the web were compared. The performed analyzes demonstrated that the hat cross-section shows a significant advantage in bending by the main axis z-z. This advantage can be used in case of lack of protection against lateral torsional buckling and a larger degree of roof slope.
This article presents the results of reinforcement cover thickness measurements carried out in several buildings erected in 2022 in Rzeszów. The results of the measurements are presented in two variants depending on the reinforcement cover thickness assumed by the designer: the first variant contains all the results and the second contains results only from places where the designed cover thickness was 25 mm. For both variants, a histogram of the percentage deviation from the design value was determined and mean values, standard deviation, coefficient of variation and maximum values of negative and positive deviation were calculated. The obtained reinforcement cover thickness distributions were used to determine the reliability of a floor slab with a simply supported beam static scheme. Analyses were carried out for 4 slabs differing in span, thickness and selected reinforcement. Using the FORM analytical method, values for the reliability index and probability of failure were determined. The reliability index values obtained were compared with the values required by EC 1990 and ISO 2394. The results obtained did not meet the standard requirements.
27 February 2020 in Journal of Civil Engineering, Environment and Architecture
Single-nave halls with a steel structure are used in industrial construction and as storage, sports, public facilities, temporary buildings, etc. In terms of design, they consist of: main load-bearing systems, purlins and support systems for the wall casing and roofing. Individual elements of the hall structure can be made of hot-rolled profiles or cold formed, thin-walled elements with slender walls. The load capacity of the roof structure of an industrial hall, unconstrained by roofing, was analysed in the paper. The rigidity of the roof structure in its plane was ensured by an appropriate roof bracing system. It was also assumed that the work of the roof structure in a perpendicular direction to the roof plane is to be similar to the behavior of a steel grate - cooperation between purlins and rigid tie rods was assumed, with vertical loads applied only to the purlins.