Objective : Gait provides a sensitive measurement for signs of aging and neurodegenerative conditions. Measurement of gait is transitioning from the laboratory environment to the clinic with the use of inertial measurement units, providing a simple and cost-effective assessment tool. However, such assessments first need validation against reference systems. The aim of this study was to validate the APDM Mobility Lab (ML) system (version 2) against a pressure sensor walkway in younger adults ( n = 18), older adults ( n = 18) and people with mild Parkinson’s disease ( n = 21) in the laboratory. Approach : Participants completed a two-minute walk over a pressure sensor walkway whilst wearing three sensors (strapped to the lumbar spine and both feet). Comparison of output from the systems was then performed. Main results : Overall, we identified that ML provided good to excellent agreement (ICC > 0.75) for gait velocity, stride length, stride length SD, cadence, stride time and stride time SD. Measures of double support time, single support time and swing time had moderate to poor agreement (ICC 0.213–0.725), particularly for younger adults and PD. Significance : Overall, Mobility Lab provides a valid system for gait data collection for clinical and research application.
Background: Identifying digital biomarkers of mobility is important for clinical trials in Parkinson’s disease (PD). Objective: To determine which digital outcome measures of mobility discriminate mobility in people with PD from healthy control (HC)
1 December 2020 in Journal of NeuroEngineering and Rehabilitation
Background and purpose: Recent findings suggest that a gait assessment at a discrete moment in a clinic or laboratory setting may not reflect functional, everyday mobility. As a step towards better understanding gait during daily life in neurological populations, we compared gait measures that best discriminated people with multiple sclerosis (MS) and people with Parkinson’s Disease (PD) from their respective, age-matched, healthy control subjects (MS-Ctl, PD-Ctl) in laboratory tests versus a week of daily life monitoring. Methods: We recruited 15 people with MS (age mean ± SD: 49 ± 10 years), 16 MS-Ctl (45 ± 11 years), 16 people with idiopathic PD (71 ± 5 years), and 15 PD-Ctl (69 ± 7 years). Subjects wore 3 inertial sensors (one each foot and lower back) in the laboratory followed by 7 days during daily life. Mann–Whitney U test and area under the curve (AUC) compared differences between PD and PD-Ctl, and between MS and MS-Ctl in the laboratory and in daily life. Results: Participants wore sensors for 60–68 h in daily life. Measures that best discriminated gait characteristics in people with MS and PD from their respective control groups were different between the laboratory gait test and a week of daily life. Specifically, the toe-off angle best discriminated MS versus MS-Ctl in the laboratory (AUC [95% CI] = 0.80 [0.63–0.96]) whereas gait speed in daily life (AUC = 0.84 [0.69–1.00]). In contrast, the lumbar coronal range of motion best discriminated PD versus PD-Ctl in the laboratory (AUC = 0.78 [0.59–0.96]) whereas foot-strike angle in daily life (AUC = 0.84 [0.70–0.98]). AUCs were larger in daily life compared to the laboratory. Conclusions: Larger AUC for daily life gait measures compared to the laboratory gait measures suggest that daily life monitoring may be more sensitive to impairments from neurological disease, but each neurological disease may require different gait outcome measures.