Nicolas Aide

Prof. Nicolas Aide

Normandie Université, Caen, France
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2017 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
NANicolas Aide
Nicolas Aide
CLCharline Lasnon
Charline Lasnon
PVPatrick Veit-Haibach
Patrick Veit-Haibach
TSTerez Sera
Terez Sera
BSBernhard Sattler
Bernhard Sattler
RBRonald Boellaard
Ronald Boellaard
Quantitative positron emission tomography/computed tomography (PET/CT) can be used as diagnostic or prognostic tools (i.e. single measurement) or for therapy monitoring (i.e. longitudinal studies) in multicentre studies. Use of quantitative parameters, such as standardized uptake values (SUVs), metabolic active tumor volumes (MATVs) or total lesion glycolysis (TLG), in a multicenter setting requires that these parameters be comparable among patients and sites, regardless of the PET/CT system used. This review describes the motivations and the methodologies for quantitative PET/CT performance harmonization with emphasis on the EANM Research Ltd. (EARL) Fluorodeoxyglucose (FDG) PET/CT accreditation program, one of the international harmonization programs aiming at using FDG PET as a quantitative imaging biomarker. In addition, future accreditation initiatives will be discussed. The validation of the EARL accreditation program to harmonize SUVs and MATVs is described in a wide range of tumor types, with focus on therapy assessment using either the European Organization for Research and Treatment of Cancer (EORTC) criteria or PET Evaluation Response Criteria in Solid Tumors (PERCIST), as well as liver-based scales such as the Deauville score. Finally, also presented in this paper are the results from a survey across 51 EARL-accredited centers reporting how the program was implemented and its impact on daily routine and in clinical trials, harmonization of new metrics such as MATV and heterogeneity features.

5 October 2018 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
NANicolas Aide
Nicolas Aide
RHRodney J. Hicks
Rodney J. Hicks
CTChristophe Le Tourneau
Christophe Le Tourneau
SLStéphanie Lheureux
Stéphanie Lheureux
Stefano FantiStefano Fanti
Stefano Fanti
Egesta LopciEgesta Lopci
Egesta Lopci
This paper follows the immunotherapy symposium held during the European Association of Nuclear Medicine (EANM) 2017 Annual Congress. The biological basis of the immune checkpoint inhibitors and the drugs most frequently used for the treatment of solid tumours are reviewed. The issues of pseudoprogression (frequency, timeline), hyperprogression and immune-related side effects are discussed, as well as their implications for patient management. A review of the recent literature on the use of FDG PET for assessment of immunotherapy is presented, and recommendations are provided for assessing tumour response and reporting immune-related side effects with FDG PET based on published data and experts’ experience. Representative clinical cases are also discussed.

4 July 2003 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
NANicolas Aide
Nicolas Aide
OCOlivier Cappele
Olivier Cappele
PBPhilippe Bottet
Philippe Bottet
HBHenri Bensadoun
Henri Bensadoun
ARArmelle Regeasse
Armelle Regeasse
GBGérard Bouvard
Gérard Bouvard

6 April 2013 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
CLCharline Lasnon
Charline Lasnon
CDCédric Desmonts
Cédric Desmonts
EQElske Quak
Elske Quak
RGRadj Gervais
Radj Gervais
PDPascal Do
Pascal Do
NANicolas Aide
Nicolas Aide
Purpose We prospectively evaluated whether a strategy using point spread function (PSF) reconstruction for both diagnostic and quantitative analysis in non-small cell lung cancer (NSCLC) patients meets the European Association of Nuclear Medicine (EANM) guidelines for harmonization of quantitative values. Methods The NEMA NU-2 phantom was used to determine the optimal filter to apply to PSF-reconstructed images in order to obtain recovery coefficients (RCs) fulfilling the EANM guidelines for tumour positron emission tomography (PET) imaging (PSFEANM). PET data of 52 consecutive NSCLC patients were reconstructed with unfiltered PSF reconstruction (PSFallpass), PSFEANM and with a conventional ordered subset expectation maximization (OSEM) algorithm known to meet EANM guidelines. To mimic a situation in which a patient would undergo pre- and post-therapy PET scans on different generation PET systems, standardized uptake values (SUVs) for OSEM reconstruction were compared to SUVs for PSFEANM and PSFallpass reconstruction. Results Overall, in 195 lesions, Bland-Altman analysis demonstrated that the mean ratio between PSFEANM and OSEM data was 1.03 [95 % confidence interval (CI) 0.94–1.12] and 1.02 (95 % CI 0.90–1.14) for SUVmax and SUVmean, respectively. No difference was noticed when analysing lesions based on their size and location or on patient body habitus and image noise. Ten patients (84 lesions) underwent two PET scans for response monitoring. Using the European Organization for Research and Treatment of Cancer (EORTC) criteria, there was an almost perfect agreement between OSEMPET1/OSEMPET2 (current standard) and OSEMPET1/PSFEANM-PET2 or PSFEANM-PET1/OSEMPET2 with kappa values of 0.95 (95 % CI 0.91–1.00) and 0.99 (95 % CI 0.96–1.00), respectively. The use of PSFallpass either for pre- or post-treatment (i.e. OSEMPET1/PSFallpass-PET2 or PSFallpass-PET1/OSEMPET2) showed considerably less agreement with kappa values of 0.75 (95 % CI 0.67–0.83) and 0.86 (95 % CI 0.78–0.94), respectively. Conclusion Protocol-optimized images and compliance with EANM guidelines allowed for a reliable pre- and post-therapy evaluation when using different generation PET systems. These data obtained in NSCLC patients could be extrapolated to other solid tumours.

17 March 2020 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
CDCédric Desmonts
Cédric Desmonts
MBMohammed Abdeldjalil Bouthiba
Mohammed Abdeldjalil Bouthiba
BEBlandine Enilorac
Blandine Enilorac
CNCatherine Nganoa
Catherine Nganoa
DADenis Agostini
Denis Agostini
NANicolas Aide
Nicolas Aide
Background: Evaluate the physical performance of the VERITON CzT camera (Spectrum Dynamics, Caesarea, Israel) that benefits from new detection architecture enabling whole-body imaging compared to that of a conventional dual-head Anger camera. Methods: Different line sources and phantom measurements were performed on each system to evaluate spatial resolution, sensitivity, energy resolution and image quality with acquisition and reconstruction parameters similar to those used in clinical routine. Extrinsic resolution was assessed using 99mTc capillary sources placed successively in air, in a head and in a body phantom filled with background activity. Spectral acquisitions for various radioelements used in nuclear medicine (99mTc, 123I, 201Tl, 111In) were performed to evaluate energy resolution by computing the FWHM of the measured photoelectric peak. Tomographic sensitivity was calculated by recording the total number of counts detected during tomographic acquisition for a set of source geometries representative of different clinical situations. Sensitivity was also evaluated in focus mode for the CzT camera, which consisted of forcing detectors to collect data in a reduced field-of-view. Image quality was assessed with a Jaszczak phantom filled with 350 MBq of 99mTc and scanned on each system with 30-,20-,10- and 5-min acquisition times. Results: Extrinsic and tomographic resolution in the brain and body phantoms at the centre of the FOV was estimated at 3.55, 7.72 and 6.66 mm for the CzT system and 2.47, 7.75 and 7.72 mm for the conventional system, respectively. The energy resolution measured at 140 keV was 5.46% versus 9.21% for the Anger camera and was higher in a same manner for all energy peaks tested. Tomographic sensitivity for a point source in air was estimated at 236 counts·s−1·MBq−1 and increased to 1159 counts·s−1·MBq−1 using focus mode, which was 1.6 times and 8 times greater than the sensitivity measured on the scintillation camera (144 counts·s−1·MBq−1). Head and body measurements also showed higher sensitivity for the CzT camera in particular with focus mode. The Jaszczak phantom showed high image contrast uniformity and a high signal-to-noise ratio on the CzT system, even when decreasing acquisition time by 6-fold. Representative clinical cases are shown to illustrate these results. Conclusion: The CzT camera has a superior sensitivity, higher energy resolution and better image contrast than the conventional SPECT camera, whereas spatial resolution remains similar. Introduction of this new technology may change current practices in nuclear medicine such as decreasing acquisition time and activity injected to patient.

1 June 2009 in The Journal of Clinical Endocrinology & Metabolism
Verified
Journal Article
Closed access
NANicolas Aide
Nicolas Aide
NHNatacha Heutte
Natacha Heutte
JRJean-Pierre Rame
Jean-Pierre Rame
ERElise Rousseau
Elise Rousseau
CLCédric Loiseau
Cédric Loiseau
SBStéphane Bardet
Stéphane Bardet
In patients with differentiated thyroid carcinoma, postablation (131)I scintigraphy aims to detect residual neck disease and distant metastases, usually found in lungs and bones. New hybrid single-photon emission computed tomography/computed tomography (SPECT-CT) cameras that permit functional and anatomical image fusion may improve its clinical relevance. Our objective was to test the added value of neck and thorax SPECT-spiral CT to whole-body scan (WBS) in postablation (131)I scintigraphy. This was a single-referral-center prospective study with a median follow-up of 21 months. Postablation (131)I WBS and neck and thorax SPECT-CT were performed in 55 consecutive patients treated in 2006. WBS and SPECT-CT data were blindly reviewed, scored negative (benign), positive (malignant), or indeterminate and were correlated to the patient outcome. At patient level, WBS and SPECT-CT were negative in 67 and 78% of patients, positive in 4 and 15%, and indeterminate in 29 and 7%, respectively. Overall, nine patients (16%) presented treatment failure (persistent or recurrent disease) 1-16 months after radioiodine ablation. In the 16 patients with indeterminate WBS, negative SPECT-CT ruled out suspicion of disease in nine of nine patients, and positive SPECT-CT confirmed malignant lesions in four of five patients. Positive SPECT-CT predicted treatment failure better than positive WBS (McNemar's test, P = 0.03). This study demonstrates the complementary role of neck and thorax SPECT-CT to WBS in postablation (131)I scintigraphy. Because SPECT-CT allows one to confirm or to rule out residual disease in most cases where WBS remains indeterminate, we recommend its use when available.