Purpose We prospectively evaluated whether a strategy using point spread function (PSF) reconstruction for both diagnostic and quantitative analysis in non-small cell lung cancer (NSCLC) patients meets the European Association of Nuclear Medicine (EANM) guidelines for harmonization of quantitative values. Methods The NEMA NU-2 phantom was used to determine the optimal filter to apply to PSF-reconstructed images in order to obtain recovery coefficients (RCs) fulfilling the EANM guidelines for tumour positron emission tomography (PET) imaging (PSFEANM). PET data of 52 consecutive NSCLC patients were reconstructed with unfiltered PSF reconstruction (PSFallpass), PSFEANM and with a conventional ordered subset expectation maximization (OSEM) algorithm known to meet EANM guidelines. To mimic a situation in which a patient would undergo pre- and post-therapy PET scans on different generation PET systems, standardized uptake values (SUVs) for OSEM reconstruction were compared to SUVs for PSFEANM and PSFallpass reconstruction. Results Overall, in 195 lesions, Bland-Altman analysis demonstrated that the mean ratio between PSFEANM and OSEM data was 1.03 [95 % confidence interval (CI) 0.94–1.12] and 1.02 (95 % CI 0.90–1.14) for SUVmax and SUVmean, respectively. No difference was noticed when analysing lesions based on their size and location or on patient body habitus and image noise. Ten patients (84 lesions) underwent two PET scans for response monitoring. Using the European Organization for Research and Treatment of Cancer (EORTC) criteria, there was an almost perfect agreement between OSEMPET1/OSEMPET2 (current standard) and OSEMPET1/PSFEANM-PET2 or PSFEANM-PET1/OSEMPET2 with kappa values of 0.95 (95 % CI 0.91–1.00) and 0.99 (95 % CI 0.96–1.00), respectively. The use of PSFallpass either for pre- or post-treatment (i.e. OSEMPET1/PSFallpass-PET2 or PSFallpass-PET1/OSEMPET2) showed considerably less agreement with kappa values of 0.75 (95 % CI 0.67–0.83) and 0.86 (95 % CI 0.78–0.94), respectively. Conclusion Protocol-optimized images and compliance with EANM guidelines allowed for a reliable pre- and post-therapy evaluation when using different generation PET systems. These data obtained in NSCLC patients could be extrapolated to other solid tumours.
Purpose: We investigated whether artificial intelligence (AI)-based denoising halves PET acquisition time in digital PET/CT. Methods: One hundred ninety-five patients referred for [18F]FDG PET/CT were prospectively included. Body PET acquisitions were performed in list mode. Original “PET90” (90 s/bed position) was compared to reconstructed ½-duration PET (45 s/bed position) with and without AI-denoising, “PET45AI and PET45”. Denoising was performed by SubtlePET™ using deep convolutional neural networks. Visual global image quality (IQ) 3-point scores and lesion detectability were evaluated. Lesion maximal and peak standardized uptake values using lean body mass (SULmax and SULpeak), metabolic volumes (MV), and liver SULmean were measured, including both standard and EARL1 (European Association of Nuclear Medicine Research Ltd) compliant SUL. Lesion-to-liver SUL ratios (LLR) and liver coefficients of variation (CVliv) were calculated. Results: PET45 showed mediocre IQ (scored poor in 8% and moderate in 68%) and lesion concordance rate with PET90 (88.7%). In PET45AI, IQ scores were similar to PET90 (P = 0.80), good in 92% and moderate in 8% for both. The lesion concordance rate between PET90 and PET45AI was 836/856 (97.7%), with 7 lesions (0.8%) only detected in PET90 and 13 (1.5%) exclusively in PET45AI. Lesion EARL1 SULpeak was not significantly different between both PET (P = 0.09). Lesion standard SULpeak, standard and EARL1 SULmax, LLR and CVliv were lower in PET45AI than in PET90 (P < 0.0001), while lesion MV and liver SULmean were higher (P < 0.0001). Good to excellent intraclass correlation coefficients (ICC) between PET90 and PET45AI were observed for lesion SUL and MV (ICC ≥ 0.97) and for liver SULmean (ICC ≥ 0.87). Conclusion: AI allows [18F]FDG PET duration in digital PET/CT to be halved, while restoring degraded ½-duration PET image quality. Future multicentric studies, including other PET radiopharmaceuticals, are warranted.
Aim The aim of the present study was to evaluate the impact of point spread function (PSF) reconstruction on quantitative values and diagnostic accuracy of FDG PET/CT for nodal staging in non–small cell lung cancer. Patients and Methods Fifty-eight consecutive PET/CT examinations were reconstructed with both ordered subset expectation maximization (OSEM) and PSF algorithms. Two readers independently performed a randomized blinded review of PET/CT examinations and gave a nodal status (N0, N1, N2, or N3) to each PET data set. When discordant, a consensus was reached with a third reader. Sensitivity, specificity, positive and negative predictive values (NPV), and positive and negative likelihood ratios (LRs) were assessed and compared using a McNemar test. All PET data sets were then independently analyzed to extract quantitative PET values in 208 nodes and compare them using Bland-Altman analysis. Results Bland-Altman analysis showed that, on average, PSF reconstruction increased SUVmax, SUVmean, and node/background ratios by 48%, 28%, and 27%, respectively. This increase was more marked for nodes less than 1 cm than for nodes 1 cm or greater (P < 0.0001 for SUVmax, SUVmean, and node/background ratios). Point spread function PET had higher sensitivity (97%) and NPV (92%) than OSEM PET (78% and 57%, respectively; P = 0.01 and P = 0.04, respectively). Negative LR was 0.04 for PSF PET and 0.31 for OSEM PET. Conclusions By improving activity recovery, especially for nonenlarged nodes, PSF significantly improves the sensitivity, NPV, and negative LR of FDG-PET for nodal staging in non–small cell lung cancer. These data suggest that preoperative invasive nodal staging may be omitted in the case of a negative PSF FDG-PET/CT.
Our purpose was to evaluate the diagnostic and prognostic value of skeletal textural features (TFs) on baseline FDG PET in diffuse large B cell lymphoma (DLBCL) patients.