Aravind C. K.

Dr. Aravind C. K.

Senior Assistant Professor at Mepco Schlenk Engineering College
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2012 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
BRB. Indu Rani
B. Indu Rani
Aravind C. K.Aravind C. K.
Aravind C. K.
GIG. Saravana Ilango
G. Saravana Ilango
CNC. Nagamani
C. Nagamani

29 August 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
Aravind C. K.Aravind C. K.
Aravind C. K.
Pandia Rajan JeyarajPandia Rajan Jeyaraj
Pandia Rajan Jeyaraj
Sivaprakash ASivaprakash A
Sivaprakash A
THANIKANTI SUDHAKAR BABUTHANIKANTI SUDHAKAR BABU
THANIKANTI SUDHAKAR BABU
Md. Rabiul IslamMd. Rabiul Islam
Md. Rabiul Islam
Synchronization is a crucial problem in the grid-connected inverter’s control and operation. A phase-locked loop (PLL) is a typical grid synchronization strategy, which ought to have a high resistance to power system uncertainties since its sensitivity influences the generated reference signal. The traditional PLL catches the phase and frequency of the input signal via the feedback loop filter (LF). In general, to enhance the steady-state capability during distorted grid conditions generally, a filter tuned for nominal frequency is used. This PLL corrects large frequency deviations around the nominal frequency, which increases the PLL’s locking time. Therefore, this paper presents an adaptive feed-forward PLL, where the input signal frequency and phase under large frequency deviations are tracked precisely, which overcomes the above-mentioned limitations. The proposed adaptive PLL consists of a feedback loop that reduces the phase error. The feed-forward loop predicts the frequency and phase error, and the frequency adaptive FIR filter reduces the ripples in output, which is due to input distortions. The adaptive mechanism adjusts the gain of the filter in accordance with the supply frequency. This reduces the phase and frequency error and also decreases the locking time under wide frequency deviations. To verify the effectiveness of the proposed adaptive feed-forward PLL, the system was tested under different grid abnormal conditions. Further, the stability analysis has been carried out via a developed prototype test platform in the laboratory. To bring the proposed simulations into real-time implementations and for control strategies, an Altera Cyclone II field-programmable gate array (FPGA) board has been used. The obtained results of the proposed PLL via simulations and hardware are compared with conventional techniques, and it indicates the superiority of the proposed method. The proposed PLL effectively able to tackle the different grid uncertainties, which can be observed from the results presented in the result section.

25 October 2018 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
SPSubramaniyan Priyavarthini
Subramaniyan Priyavarthini
Aravind C. K.Aravind C. K.
Aravind C. K.
CNChilakapati Nagamani
Chilakapati Nagamani
SGSaravana Ilango Ganesan
Saravana Ilango Ganesan
Generally, a dynamic voltage restorer (DVR) installed in a grid‐connected wind farm, is utilised for mitigating sag/swell in grid voltage and hence stays idle under nominal grid voltage. To enhance the utility of such a DVR, this study proposes to install a solar photovoltaic (PV) plant in the DVR, so that in addition to addressing sag/swell in grid voltage, energy can be harvested and injected into the grid from the PV plant using the same DVR. Various modes of operations of the proposed PV‐assisted DVR (PVDVR) are described, underlining the logically set priorities. Comprehensive mathematical and graphical analyses are developed to explore the boundaries of the operating region of each mode of PVDVR considering fluctuations in grid voltage and available PV power. Investigations are carried out in a 50 MW wind farm and a 0.75 kW laboratory induction machine (both grid connected) each with a suitable DVR. Results of simulations in power systems computer‐aided design/electro‐magnetic transient design and control and laboratory tests demonstrate improved utilisation of DVR when fed from PV plant.

8 March 2017 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
Aravind C. K.Aravind C. K.
Aravind C. K.
BRB. Indu Rani
B. Indu Rani
CMChakkarapani Manickam
Chakkarapani Manickam
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
SGSaravana Ilango Ganesan
Saravana Ilango Ganesan
CNChilakapati Nagamani
Chilakapati Nagamani
This paper presents a detailed analysis of Type-3 phase locked loop (PLL) under wide variation in input voltage and frequency. Using small signal modeling, the performance of both single loop and dual loop Type-3 PLL for variation in input voltage and frequency is studied. The analysis shows that for the same bandwidth, both the single loop and dual loop Type-3 PLLs exhibit similar dynamics provided the supply voltage is balanced. However, under voltage sag conditions, dual loop PLL shows improved dynamic response without affecting its stability. Further, the tracking time is reduced as the feed forward frequency is a function of supply frequency. To improve the filtering characteristics under frequency deviations, a dual loop Type 3 adaptive PLL which accurately tracks the phase and frequency of the input signal under wide frequency deviations is developed. Simulations are carried out in MATLAB and experimentally verified by implementing in ALTERA cyclone II Field Programmable Gate Array (FPGA) board.

20 May 2024 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
JRJain Vinith P R
Jain Vinith P R
NKNavin Sam K
Navin Sam K
VTVidya T
Vidya T
Aravind C. K.Aravind C. K.
Aravind C. K.
Solar photovoltaic (SPV) generators play a vital role in the global pursuit of sustainable energy. However, the intermittent nature of SPV generators poses a challenge to power system planning. Accurate long-term SPV power forecasting is essential, but obtaining high-quality training data for many years is cumbersome due to faults in sensors, communication, or databases, leading to missing values. This paper proposes an attention network (AN) for SPV power imputation to address missing historical data. In addition, the SPV power forecasting model using BDLSTM NN is proposed for forecasting the SPV power in the long-term horizon. During training, the weights and biases of the imputation and forecasting models are proposed to be optimized using the Aquila optimization algorithm (AOA). Training and testing results substantiate that the proposed imputation and forecasting models consistently attain superior accuracy with a reduction in training time regardless of the missing rates, climatic patterns, and seasons as compared to benchmark models.

24 September 2022 in IET Renewable Power Generation
Verified
Journal Article
Open access
Aravind C. K.Aravind C. K.
Aravind C. K.
Pandia Rajan JeyarajPandia Rajan Jeyaraj
Pandia Rajan Jeyaraj
BABrindhu Kumari Albert
Brindhu Kumari Albert
THANIKANTI SUDHAKAR BABUTHANIKANTI SUDHAKAR BABU
THANIKANTI SUDHAKAR BABU
Manoj Kumar NallapaneniManoj Kumar Nallapaneni
Manoj Kumar Nallapaneni
Hassan Haes AlhelouHassan Haes Alhelou
Hassan Haes Alhelou
This paper presents a solar dynamic voltage restorer for hybrid series‐connected solar‐wind farms to mitigate the power quality problems. The operating region of the proposed hybrid system is derived and studied through graphical analysis. Upon examination of the system's operation under various grid conditions, the feasibility of solar PV power injected into the grid is verified. It is further proved that the series injection of voltage is also capable of mitigating the effects of voltage sag/swell, and unbalance, which have adverse effects on wind‐connected induction generators. Further, the effectiveness of Solar DVR to mitigate the fault ride‐through capability of the wind farm is analyzed. The non‐requirement for an energy storage device such as a battery is also validated. A control system for the series PV inverter is proposed and the computer simulations are performed to confirm the efficacy and ride‐through capability of the system.