Tra Nguyen Phan

Mrs. Tra Nguyen Phan

Mid Sweden University
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2018 in IEEE Access
Verified
Journal Article
Open access
FTFatemeh Tabei
Fatemeh Tabei
RKRajnish Kumar
Rajnish Kumar
Tra Nguyen PhanTra Nguyen Phan
Tra Nguyen Phan
DMDavid D. McManus
David D. McManus
Jo Woon ChongJo Woon Chong
Jo Woon Chong
Photoplethysmography (PPG) is a technique to detect blood volume changes in an optical way. Representative PPG applications are the measurements of oxygen saturation, heart rate, and respiratory rate. However, the PPG signals are sensitive to motion and noise artifacts (MNAs), especially when they are obtained from smartphone cameras. Moreover, the PPG signals are different among users and each individual's PPG signal has a unique characteristic. Hence, an effective MNA detection and reduction method for smartphone PPG signals, which adapts itself to each user in a personalized way, is highly demanded. In this paper, a concept of the probabilistic neural network is introduced to be used with the proposed extracted parameters. The signal amplitude, standard deviation of peak to peak time intervals and amplitudes, along with the mean of moving standard deviation, signal slope changes, and the optimal autoregressive model order are proposed for effective MNA detection. Accordingly, the performance of the proposed personalized algorithm is compared with conventional MNA detection algorithms. As for the performance metrics, we considered accuracy, sensitivity, and specificity. The results show that the overall performance of the personalized MNA detection is enhanced compared to the generalized algorithm. The average values of the accuracy, sensitivity, and specificity of the personalized one are 98.07%, 92.6%, and 99.78%, respectively, while these are 89.92%, 84.21%, and 93.63% for the general one.

30 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Tra Nguyen PhanTra Nguyen Phan
Tra Nguyen Phan
JAjesus javier lechuga aranda
jesus javier lechuga aranda
BOBengt Oelmann
Bengt Oelmann
SBSebastian Bader
Sebastian Bader
Investigating the coil–magnet structure plays a significant role in the design process of the electromagnetic energy harvester due to the effect on the harvester’s performance. In this paper, the performance of four different electromagnetic vibration energy harvesters with cylindrical shapes constrained in the same volume were under investigation. The utilized structures are (i) two opposite polarized magnets spaced by a mild steel; (ii) a Halbach array with three magnets and one coil; (iii) a Halbach array with five magnets and one coil; and (iv) a Halbach array with five magnets and three coils. We utilized a completely automatic optimization procedure with the help of an optimization algorithm implemented in Python, supported by simulations in ANSYS Maxwell and MATLAB Simulink to obtain the maximum output power for each configuration. The simulation results show that the Halbach array with three magnets and one coil is the best for configurations with the Halbach array. Additionally, among all configurations, the harvester with two opposing magnets provides the highest output power and volume power density, while the Halbach array with three magnets and one coil provides the highest mass power density. The paper also demonstrates limitations of using the electromagnetic coupling coefficient as a metric for harvester optimization, if the ultimate goal is maximization of output power.

12 February 2017 in Sensors
Verified
Journal Article
Open access
PDF file
RZRifat Zaman
Rifat Zaman
CCChae Ho Cho
Chae Ho Cho
KHKonrad Hartmann
Konrad Hartmann
Tra Nguyen PhanTra Nguyen Phan
Tra Nguyen Phan
GYGwonchan Yoon
Gwonchan Yoon
Jo Woon ChongJo Woon Chong
Jo Woon Chong
We hypothesize that our fingertip image-based heart rate detection methods using smartphone reliably detect the heart rhythm and rate of subjects. We propose fingertip curve line movement-based and fingertip image intensity-based detection methods, which both use the movement of successive fingertip images obtained from smartphone cameras. To investigate the performance of the proposed methods, heart rhythm and rate of the proposed methods are compared to those of the conventional method, which is based on average image pixel intensity. Using a smartphone, we collected 120 s pulsatile time series data from each recruited subject. The results show that the proposed fingertip curve line movement-based method detects heart rate with a maximum deviation of 0.0832 Hz and 0.124 Hz using time- and frequency-domain based estimation, respectively, compared to the conventional method. Moreover, another proposed fingertip image intensity-based method detects heart rate with a maximum deviation of 0.125 Hz and 0.03 Hz using time- and frequency-based estimation, respectively.

23 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Tra Nguyen PhanTra Nguyen Phan
Tra Nguyen Phan
SBSebastian Bader
Sebastian Bader
BOBengt Oelmann
Bengt Oelmann
The introduction of nonlinearities into energy harvesting in order to improve the performance of linear harvesters has attracted a lot of research attention recently. The potential benefits of nonlinear harvesters have been evaluated under sinusoidal or random excitation. In this paper, the performances of electromagnetic energy harvesters with linear and nonlinear springs are investigated under real vibration data. Compared to previous studies, the parameters of linear and nonlinear harvesters used in this paper are more realistic and fair for comparison since they are extracted from existing devices and restricted to similar sizes and configurations. The simulation results showed that the nonlinear harvester did not generate higher power levels than its linear counterpart regardless of the excitation category. Additionally, the effects of nonlinearities were only available under a high level of acceleration. The paper also points out some design concerns when harvesters are subjected to real vibrations.

10 December 2015 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
Tra Nguyen PhanTra Nguyen Phan
Tra Nguyen Phan
MAMehdi Azadmehr
Mehdi Azadmehr
CLCuong Phu Le
Cuong Phu Le
EHEinar Halvorsen
Einar Halvorsen
This paper presents design and simulation of a power electronic interface circuit for MEMS electrostatic energy harvesters. The designed circuit is applicable to highly miniaturized electrostatic harvesters with small transducer capacitances below 10 pF. It is based on comb- drive harvesters with two anti-phase capacitors that are connected as charge pumps and uses a flyback-path scheme. Controlled activation and deactivation of sub-circuits, some by help of clocking, were exploited to reduce power consumption down to 1.03 μW. Net power generation can be achieved with as low initial voltage as 3.0 V.

14 March 2019 in arXiv
Verified
Preprint
Open access
PDF file
CCChae Ho Cho
Chae Ho Cho
FTFatemehsadat Tabei
Fatemehsadat Tabei
Tra Nguyen PhanTra Nguyen Phan
Tra Nguyen Phan
YKYeesock Kim
Yeesock Kim
JCJo Woon Chong
Jo Woon Chong
The rapid enhancement of central power unit CPU performance enables the development of computationally-intensive healthcare mobile applications for smartphones and wearable devices. However, computationally intensive mobile applications require significant application development time during the application porting procedure when the number of considering target devices operating systems OSs is large. In this paper, we propose a novel retargetable application development platform for healthcare mobile applications, which reduces application development time with maintaining the performance of the algorithm. Although the number of applications target OSs increases, the amount of time required for the code conversion step in the application porting procedure remains constant in the proposed retargetable platform. Experimental results show that our proposed retargetable platform gives reduced application development time compared to the conventional platform with maintaining the performance of the mobile application.