Chae Ho Cho

Mr. Chae Ho Cho


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2017 in Sensors
Verified
Journal Article
Open access
PDF file
RZRifat Zaman
Rifat Zaman
CCChae Ho Cho
Chae Ho Cho
KHKonrad Hartmann
Konrad Hartmann
Tra Nguyen PhanTra Nguyen Phan
Tra Nguyen Phan
GYGwonchan Yoon
Gwonchan Yoon
Jo Woon ChongJo Woon Chong
Jo Woon Chong
We hypothesize that our fingertip image-based heart rate detection methods using smartphone reliably detect the heart rhythm and rate of subjects. We propose fingertip curve line movement-based and fingertip image intensity-based detection methods, which both use the movement of successive fingertip images obtained from smartphone cameras. To investigate the performance of the proposed methods, heart rhythm and rate of the proposed methods are compared to those of the conventional method, which is based on average image pixel intensity. Using a smartphone, we collected 120 s pulsatile time series data from each recruited subject. The results show that the proposed fingertip curve line movement-based method detects heart rate with a maximum deviation of 0.0832 Hz and 0.124 Hz using time- and frequency-domain based estimation, respectively, compared to the conventional method. Moreover, another proposed fingertip image intensity-based method detects heart rate with a maximum deviation of 0.125 Hz and 0.03 Hz using time- and frequency-based estimation, respectively.

22 March 2018 in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
Verified
Journal Article
Closed access
Jo Woon ChongJo Woon Chong
Jo Woon Chong
CCChae Ho Cho
Chae Ho Cho
FTFatemeh Tabei
Fatemeh Tabei
DLDuy Le-Anh
Duy Le-Anh
NENada Esa
Nada Esa
KCKi Chon
Ki Chon
We have recently found that our previously-developed atrial fibrillation (AF) detection algorithm for smartphones can give false positives when subjects' fingers or hands move, as we rely on proper finger placement over the smartphone camera to collect the signal of interest. Specifically, smartphone camera pulsatile signals that are obtained from normal sinus rhythm (NSR) subjects but are corrupted by motion and noise artifacts (MNAs) are frequently detected as AF. AF and motion-corrupted episodes have the similar characteristic that pulse-to-pulse intervals are irregular. We have developed an MNA-resilient smartphone-based AF detection algorithm that first discriminates and eliminates MNA-corrupted episodes in smartphone camera recordings, and then detects AF in MNA-free recordings. We found that MNA-corrupted episodes have highly varying pulse slope, large turning point ratio, or large kurtosis values in smartphone signals compared to MNA-free AF and NSR episodes. We first use these three metrics for MNA discrimination and exclusion. Then, AF is detected in MNA-free signals using our previous algorithm. The capability to discriminate MNAs and AFs separately in smartphone signals increases the specificity of AF detection. To evaluate the performance of the proposed MNA-resilient AF algorithm, 99 subjects, including 88 study participants with AF at baseline and in NSR after electrical cardioversion as well as 11 participants with MNA-corrupted NSR, were recruited. Using iPhone 4S, 5S, and 6S models, we collected 2-min pulsatile time series from each subject. The clinical results show that the accuracy, sensitivity, and specificity of the proposed AF algorithm are 0.97, 0.98, and 0.97, respectively, which are higher than those of the previous AF algorithm.

14 March 2019 in arXiv
Verified
Preprint
Open access
PDF file
CCChae Ho Cho
Chae Ho Cho
FTFatemehsadat Tabei
Fatemehsadat Tabei
Tra Nguyen PhanTra Nguyen Phan
Tra Nguyen Phan
YKYeesock Kim
Yeesock Kim
JCJo Woon Chong
Jo Woon Chong
The rapid enhancement of central power unit CPU performance enables the development of computationally-intensive healthcare mobile applications for smartphones and wearable devices. However, computationally intensive mobile applications require significant application development time during the application porting procedure when the number of considering target devices operating systems OSs is large. In this paper, we propose a novel retargetable application development platform for healthcare mobile applications, which reduces application development time with maintaining the performance of the algorithm. Although the number of applications target OSs increases, the amount of time required for the code conversion step in the application porting procedure remains constant in the proposed retargetable platform. Experimental results show that our proposed retargetable platform gives reduced application development time compared to the conventional platform with maintaining the performance of the mobile application.