Jonghyun Kim

Prof. Jonghyun Kim


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2017 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
SLSeunghee Lee
Seunghee Lee
YLYang-Soo Lee
Yang-Soo Lee
JKJonghyun Kim
Jonghyun Kim
The Fugl-Meyer assessment (FMA) is the most popular instrument for evaluating upper extremity motor function in stroke patients. However, it is a labor-intensive and timeconsuming method. This paper proposes a novel automated FMA system to overcome these limitations of the FMA. For automation, we used Kinect v2 and force sensing resistor sensors owing to their convenient installation as compared with body-worn sensors. Based on the linguistic guideline of the FMA, a rule-based binary logic classification algorithm was developed to assign FMA scores using the extracted features obtained from the sensors. The algorithm is appropriate for clinical use because it is not based on machine learning, which requires additional learning processes with a large amount of clinical data. The proposed system was able to automate 79% of the FMA tests because of optimized sensor selection and the classification algorithm. In clinical trials conducted with nine stroke patients, the proposed system exhibited high scoring accuracy (92%) and time efficiency (85% reduction in clinicians’ required time).

14 August 2015 in Sensors
Verified
Journal Article
Open access
PDF file
POPaul Otten
Paul Otten
JKJonghyun Kim
Jonghyun Kim
SSSang Hyuk Son
Sang Hyuk Son
Standard upper-limb motor function impairment assessments, such as the Fugl-Meyer Assessment (FMA), are a critical aspect of rehabilitation after neurological disorders. These assessments typically take a long time (about 30 min for the FMA) for a clinician to perform on a patient, which is a severe burden in a clinical environment. In this paper, we propose a framework for automating upper-limb motor assessments that uses low-cost sensors to collect movement data. The sensor data is then processed through a machine learning algorithm to determine a score for a patient’s upper-limb functionality. To demonstrate the feasibility of the proposed approach, we implemented a system based on the proposed framework that can automate most of the FMA. Our experiment shows that the system provides similar FMA scores to clinician scores, and reduces the time spent evaluating each patient by 82%. Moreover, the proposed framework can be used to implement customized tests or tests specified in other existing standard assessment methods.

3 March 2020 in Advanced Healthcare Materials
Verified
Journal Article
Closed access
PDF file
SLSeungmin Lee
Seungmin Lee
JKJin‐Young Kim
Jin‐Young Kim
JKJunyoung Kim
Junyoung Kim
AHAli Kafash Hoshiar
Ali Kafash Hoshiar
JPJongeon Park
Jongeon Park
HCHongsoo Choi
Hongsoo Choi

25 January 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
MSMinsu Song
Minsu Song
JKJonghyun Kim
Jonghyun Kim
Enhancing motor imagery (MI) results in amplified event-related desynchronization (ERD) and is important for MI-based rehabilitation and brain-computer interface (BCI) applications. Many attempts to enhance MI by providing visual guidance have been reported. We believe that the rubber hand illusion (RHI), which induces body ownership over an external object, can provide better guidance to enhance MI; thus, an RHI-based paradigm with motorized moving rubber hand was proposed. To validate the proposed MI enhancing paradigm, we conducted an experimental comparison among paradigms with twenty healthy subjects. The peak amplitude and arrival times of ERD were compared at contralateral and ipsilateral EEG channels. We found significantly amplified ERD caused by the proposed paradigm, which is similar to the ERD caused by motor execution. In addition, the arrival time suggests that the proposed paradigm is applicable for BCI. In conclusion, the proposed paradigm can significantly enhance MI with better characteristics for use with BCI.

4 June 2018 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
SCSeoyoung Choi
Seoyoung Choi
YSYong Beom Shin
Yong Beom Shin
SKSoo-Yeon Kim
Soo-Yeon Kim
JKJonghyun Kim
Jonghyun Kim
To provide effective interventions for spasticity, accurate and reliable spasticity assessment is essential. For the assessment, the Modified Tardieu Scale (MTS) has been widely used owing to its simplicity and convenience. However, it has poor or moderate accuracy and reliability. We proposed a novel inertial measurement unit (IMU)-based MTS assessment system to improve the accuracy and reliability of the MTS itself. The proposed system consists of a joint angle calculation algorithm, a function to detect abnormal muscle reaction (a catch and clonus), and a visual biofeedback mechanism. Through spastic knee and ankle joint assessment, the proposed IMU-based MTS assessment system was compared with the conventional MTS assessment system in 28 children with cerebral palsy by two raters. The results showed that the proposed system has good accuracy (root mean square error < 3.2°) and test-retest and inter-rater reliabilities (ICC > 0.8), while the conventional MTS system has poor or moderate reliability. Moreover, we found that the deteriorated reliability of the conventional MTS system comes from its goniometric measurement as well as from irregular passive stretch velocity. The proposed system, which is clinically relevant, can significantly improve the accuracy and reliability of the MTS in lower limbs for children with cerebral palsy.

12 July 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MSMinsu Song
Minsu Song
JKJonghyun Kim
Jonghyun Kim
Goal: For healthcare and clinical use, ambulatory gait monitoring systems using inertial sensors have been developed to estimate the user gait parameters, such as walking speed, stride time, and stride length. However, to adapt the systems effectively to daily-life activities, they need to be able to classify the gait activities of daily-life to obtain the parameters for each activity. In this study, we propose a simple classification algorithm based on a single inertial sensor for ease of use, which classifies three major gait activities: leveled walk, ramp walk, and stair walk. Method: The classification can be performed with gait parameter estimation simultaneously. The developed system that includes classification and parameter estimation algorithms was evaluated with eight healthy subjects within a gait lab and on an outdoor daily-life walking course. Results: The results showed that the estimated gait parameters were comparable to existing studies (range of walking speed root mean square error: 0.059-0.129 m/s), and the classification accuracy was sufficiently high for all three gait activities: 98.5% for the indoor gait lab experiment and 95.5% for the outdoor complex daily-life walking course experiment. Conclusion: The proposed system is simple and effective for daily-life gait analysis, including gait activity classification and gait parameter estimation for each activity.