Molecular sensors and molecular electronics are a major component of a recent research area known as bionanotechnology, which merges biology with nanotechnology. This new class of biosensors and bioelectronics has been a subject of intense research over the past decade and has found application in a wide variety of fields. The unique characteristics of these biomolecular transduction systems has been utilized in applications ranging from solar cells and single-electron transistors (SETs) to fluorescent sensors capable of sensitive and selective detection of a wide variety of targets, both organic and inorganic. This review will discuss three major systems in the area of molecular sensors and electronics and their application in unique technological innovations. Firstly, the synthesis of optoelectric bacteriorhodopsin (bR) and its application in the field of molecular sensors and electronics will be discussed. Next, this article will discuss recent advances in the synthesis and application of semiconductor quantum dots (QDs). Finally, this article will conclude with a review of the new and exciting field of noble metal nanoclusters and their application in the creation of a new class of fluorescent sensors.
The amorphous to anatase transformation of anodized nanotubular titania surfaces has been studied by x-ray diffraction and transmission electron microscopy (TEM). A more rapid heat treatment for conversion of amorphous to crystalline anatase favorable for orthopedic implant applications was demonstrated. Nanotube titania surfaces were fabricated by electrochemical anodization of Ti6Al4V in an electrolyte containing 0.2 wt% NH 4 F, 60% ethylene glycol and 40% deionized water. The resulting surfaces were systematically heat treated in air with isochronal and isothermal experiments to study the temperature and time dependent transformation respectively. Energy dispersive spectroscopy shows that the anatase phase transformation of TiO 2 in the as-anodized amorphous nanotube layer can be achieved in as little as 5 min at 350 °C in contrast to reports of higher temperature and much longer time. Crystallinity analysis at different temperatures and times yield transformation rate coefficients and activation energy for crystalline anatase coalescence. TEM confirms the (101) TiO 2 presence within the nanotubes. These results confirm that for applications where amorphous titania nanotube surfaces are converted to crystalline anatase, a 5 min production flow-through heating process could be used instead of a 3 h batch process, reducing time, cost, and complexity.
Background. Cochlear implants have become an accepted and successful treatment for profound sensorineural deafness in both children and adults. Essential to the effective and efficient localized stimulation of the auditory nerves, is the position of the implant electrode array stimulating sites within the scala tympani (ST). However, the small size, delicate internal structures and helical shape of the cochlear chambers complicate the matter of precise positioning of the implant electrode array. The design, fabrication process, and in vitro testing of a fluid actuator to steer a thin-film electrode array is presented. The application chosen to show feasibility is for a cochlear implant, however, the actuator might be used for cortical electrode arrays, for example. Method of Approach. The actuator functions by a change of internal fluid pressure within one or more flattened and curled polymer microtubes, expanding the highly elliptical cross section of each tube thereby stiffening it and causing a change in its curling radius. The straightening from an initially helical shape allows insertion of an attached electrode array into the basal end of the in vitro cochlea and as the insertion proceeds the pressure is decreased allowing the straightened electrode array to controllably return to its initial helical shape. The allowable envelope of the scala tympani of a guinea pig was determined from published data and the actuator was designed and fabricated accordingly. Results. Multiple actuators were fabricated and tested in vitro. The insertion tests helped to confirm the viability of using this type of actuation to facilitate the insertion of an electrode array into the ST. These tests were performed in a minimal amount of time and often on the first attempt. The actuator reached the furthest extent of the in vitro cavity and achieved a position adjacent to the modiolus. Conclusions. In vitro insertion tests show that the actuator can deliver a thin-film electrode array to a depth of more than one turn into the in vitro scala tympani within a few minutes under open-loop, manual control.
Orthopedic implants requiring osseointegration are often surface modified; however, implants may shed these coatings and generate wear debris leading to complications. Titanium nanotubes (TiNT), a new surface treatment, may promote osseointegration. In this study, in vitro (rat marrow-derived bone marrow cell attachment and morphology) and in vivo (rat model of intramedullary fixation) experiments characterized local and systemic responses of two TiNT surface morphologies, aligned and trabecular, via animal and remote organ weight, metal ion, hematologic, and nondecalcified histologic analyses. In vitro experiments showed total adherent cells on trabecular and aligned TiNT surfaces were greater than control at 30 min and 4 h, and cells were smaller in diameter and more eccentric. Control animals gained more weight, on average; however, no animals met the institutional trigger for weight loss. No hematologic parameters (complete blood count with differential) were significantly different for TiNT groups vs. control. Inductively coupled plasma mass spectrometry (ICP-MS) showed greater aluminum levels in the lungs of the trabecular TiNT group than in those of the controls. Histologic analysis demonstrated no inflammatory infiltrate, cytotoxic, or necrotic conditions in proximity of K-wires. There were significantly fewer eosinophils/basophils and neutrophils in the distal region of trabecular TiNT-implanted femora; and, in the midshaft of aligned TiNT-implanted femora, there were significantly fewer foreign body giant/multinucleated cells and neutrophils, indicating a decreased immune response in aligned TiNT-implanted femora compared to controls.