The amorphous to anatase transformation of anodized nanotubular titania surfaces has been studied by x-ray diffraction and transmission electron microscopy (TEM). A more rapid heat treatment for conversion of amorphous to crystalline anatase favorable for orthopedic implant applications was demonstrated. Nanotube titania surfaces were fabricated by electrochemical anodization of Ti6Al4V in an electrolyte containing 0.2 wt% NH 4 F, 60% ethylene glycol and 40% deionized water. The resulting surfaces were systematically heat treated in air with isochronal and isothermal experiments to study the temperature and time dependent transformation respectively. Energy dispersive spectroscopy shows that the anatase phase transformation of TiO 2 in the as-anodized amorphous nanotube layer can be achieved in as little as 5 min at 350 °C in contrast to reports of higher temperature and much longer time. Crystallinity analysis at different temperatures and times yield transformation rate coefficients and activation energy for crystalline anatase coalescence. TEM confirms the (101) TiO 2 presence within the nanotubes. These results confirm that for applications where amorphous titania nanotube surfaces are converted to crystalline anatase, a 5 min production flow-through heating process could be used instead of a 3 h batch process, reducing time, cost, and complexity.
1 December 2025 in Discover Mechanical Engineering
This study delivers a critical bibliometric and technical synthesis of finite element analysis (FEA)-based optimization of stress concentration factors (SCFs) in stepped flat tension bars (2005–2025). Analysis of 747 publications reveals a clear evolution from early validation studies to optimization-driven, application-ready frameworks. Comparisons of the most-cited works show methodological advances from mesh-converged parametric FEA and experimental benchmarking to evolutionary algorithms, surrogate modeling, and recent AI/ML-enhanced pipelines, though reproducibility and experimental validation remain limited. Keyword clusters align strongly with aerospace, automotive, and energy applications, while biomedical and microscale domains remain underexplored. Emerging research (2023–2025) highlights transformative directions: AI-driven surrogates for rapid SCF prediction, HPC-enabled digital twins for real-time monitoring, and additive manufacturing-specific SCF behaviors. These advances shift the field toward dynamic, data-informed frameworks that integrate computation, optimization, and sensing. By coupling bibliometric mapping with technical interpretation, this study identifies not only the past trajectories but also future opportunities, AI-informed predictive design, multiscale SCF modeling, and optimization for advanced materials, positioning bibliometrics as a strategic tool to guide next-generation structural design. References to ‘biomedical’ and ‘microscale’ indicate emergent mentions in the bibliometric maps (keywords and small clusters) rather than large, focused subfields within the Dimensions.ai export. These areas appeared only in a minority of records and are identified here as promising, under-explored directions requiring targeted systematic reviews and experimental benchmarking.
19 April 2017 in Journal of Bio- and Tribo-Corrosion
Category: Basic Sciences/Biologics Introduction/Purpose: Solid biologic fixation at the bone-implant interface provides long-term stability of orthopaedic implants. Historically, coatings and surface treatments on implant surfaces have been used to promote osseointegration of orthopaedic implants. The purpose of this research study is to evaluate two morphologies of titania nanotube (TiNT) surfaces via in vitro experiments as well as an in vivo model of femoral intramedullary fixation, in order to assess the influence of TiNT structure on de novo bone formation and bone-implant stability. Methods: TiNT structures were grown from Ti-6Al-4 V materials via an established electrochemical anodization process. Samples were either sonicated then annealed (Aligned TiNT) or annealed without prior sonication (Trabecular TiNT), to produce different morphologies. As-received titanium alloy was the control. Marrow-derived stem cells were isolated from long bones of Sprague Dawley rats and cultured on samples. Alkaline phosphatase (ALP) and osteocalcin (OC) expression by stem cells were assessed via ELISA. Cells were lysed and subjected to quantitative polymerase chain reaction (qPCR) to assess Col1a1, osteonectin, and IGF- 1 expression. An in vivo study evaluated bone formation at 4- and 12-week endpoints. Eight female Sprague Dawley rats per group per endpoint received bilateral Ti-6Al-4 V K-wires as femoral implants. Left femur received control, while right femur received Aligned/Trabecular TiNT K-wire. Bone formation was assessed via microCT, backscatter electron imaging (BEI), and non- decalcified histologic analyses. Results: Aligned and Trabecular TiNT groups demonstrated higher ALP activity than control at 2 and 3 weeks. The in vivo study demonstrated increased bone volume fractions (BV/TV) and total bone volume (TBV) for TiNT surfaces (microCT). The ratio of both BV/TV and TBV in the distal VOI were nearly equivalent for both TiNT surfaces, indicating similar bone formation between both TiNT surfaces and control. In the midshaft VOI, the ratios between TiNT surfaces and control were 1.5 or greater, indicating increased bone formation. At 12 weeks, the bone-implant contact fraction ratio (BEI) showed Aligned TiNT and Trabecular TiNT were 1.3 and 1.4 times greater than control, respectively. Histologic analysis showed both TiNT surfaces had 1.5 times the bone-implant contact as control. Conclusion: In vitro studies demonstrated improved support for osteogenic functions of cultured marrow-derived stem cells on TiNT surfaces compared to controls. μCT, BEI, and histologic analyses associated with the in vivo study demonstrated increased bone formation in the TiNT femora, at specific timepoints and VOIs.
2 January 2026 in Mechanics Based Design of Structures and Machines