Christoph Thorwartl

Mr. Christoph Thorwartl

Human Motion Analytics, Salzburg Research Forschungsgesellschaft mbH, Salzburg, Austria
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2019 in Frontiers in Sports and Active Living
Verified
Journal Article
Open access
PDF file
AÁAaron Martínez Álvarez
Aaron Martínez Álvarez
RBRichard Brunauer
Richard Brunauer
VVVerena Venek
Verena Venek
CSCory Snyder
Cory Snyder
RJRüdiger Jahnel
Rüdiger Jahnel
Thomas StögglThomas Stöggl
Thomas Stöggl
Several methodologies have been proposed to determine turn switches in alpine skiing. A recent study using inertial measurement units (IMU) was able to accurately detect turn switch points in controlled lab conditions. However, this method has yet to be validated during actual skiing in the field. The aim of this study was to further develop and validate this methodology to accurately detect turns in the field, where factors such as slope conditions, velocity, turn length, and turn style can influence the recorded data. A secondary aim was to identify runs. Different turn styles were performed (carving long, short, drifted, and snowplow turns) and the performance of the turn detection algorithm was assessed using the ratio, precision, and recall. Short carved turns showed values of 0.996 and 0.996, carving long 1.007 and 0.993, drifted 0.833 and 1.000 and snowplow 0.538 and 0.839 for ratio and precision, respectively. The results indicated that the improved system was valid and accurate for detecting runs and carved turns. However, for drifted turns, while all the turns detected were real, some real turns were missing. Further development needs to be done to include snowplow skiing.

2 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Christoph ThorwartlChristoph Thorwartl
Christoph Thorwartl
JKJosef Kröll
Josef Kröll
ATAndreas Tschepp
Andreas Tschepp
HHHelmut Holzer
Helmut Holzer
WTWolfgang Teufl
Wolfgang Teufl
Thomas StögglThomas Stöggl
Thomas Stöggl
Introduction: Ski deflection is a performance-relevant factor in alpine skiing and the segmental and temporal curvature characteristics (m−1) along the ski have lately received particular attention. Recently, we introduced a PyzoFlex® ski deflection measurement prototype that demonstrated high reliability and validity in a quasi-static setting. The aim of the present work is to test the performance of an enhanced version of the prototype in a dynamic setting both in a skiing-like bending simulation as well as in a field proof-of-concept measurement. Material and methods: A total of twelve sensor foils were implemented on the upper surface of the ski. The ski sensors were calibrated with an empirical curvature model and then deformed on a programmable bending robot with the following program: 20 times at three different deformation velocities (vslow, vmedium, vfast) with (1) central bending, (2) front bending, (3) back bending, (4) edging left, and (5) edging right. For reliability assessment, pairs of bending cycles (cycle 1 vs. cycle 10 and cycle 10 vs. cycle 20) at vslow, vmedium, and vfast and between pairs of velocity (vslow vs. vmedium and vslow vs. vfast) were evaluated by calculating the change in the mean (CIM), coefficient of variation (CV) and intraclass correlation coefficient (ICC 3.1) with a 95% confidence interval. For validity assessment, the calculated segment-wise mean signals were compared with the values that were determined by 36 infrared markers that were attached to the ski using an optoelectrical measuring system (Qualisys). Results: High reliability was found for pairs of bending cycles (CIM −0.69–0.24%, max CV 0.28%, ICC 3.1 > 0.999) and pairs of velocities (max CIM = 3.03%, max CV = 3.05%, ICC 3.1 = 0.997). The criterion validity based on the Pearson correlation coefficient was r = 0.98. The accuracy (systematic bias) and precision (standard deviation), were −0.003 m−1 and 0.047 m−1, respectively. Conclusions: The proof-of-concept field measurement has shown that the prototype is stable, robust, and waterproof and provides characteristic curvature progressions with plausible values. Combined with the high laboratory-based reliability and validity of the PyzoFlex® prototype, this is a potential candidate for smart ski equipment.

16 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Christoph ThorwartlChristoph Thorwartl
Christoph Thorwartl
JKJosef Kröll
Josef Kröll
ATAndreas Tschepp
Andreas Tschepp
PSPhilipp Schäffner
Philipp Schäffner
HHHelmut Holzer
Helmut Holzer
Thomas StögglThomas Stöggl
Thomas Stöggl
The ski deflection with the associated temporal and segmental curvature variation can be considered as a performance-relevant factor in alpine skiing. Although some work on recording ski deflection is available, the segmental curvature among the ski and temporal aspects have not yet been made an object of observation. Therefore, the goal of this study was to develop a novel ski demonstrator and to conceptualize and validate an empirical curvature model. Twenty-four PyzoFlex® technology-based sensor foils were attached to the upper surface of an alpine ski. A self-developed instrument simultaneously measuring sixteen sensors was used as a data acquisition device. After calibration with a standardized bending test, using an empirical curvature model, the sensors were applied to analyze the segmental curvature characteristic (m−1) of the ski in a quasi-static bending situation at five different load levels between 100 N and 230 N. The derived curvature data were compared with values obtained from a high-precision laser measurement system. For the reliability assessment, successive pairs of trials were evaluated at different load levels by calculating the change in mean (CIM), the coefficient of variation (CV) and the intraclass correlation coefficient (ICC 3.1) with a 95% confidence interval. A high reliability of CIM −1.41–0.50%, max CV 1.45%, and ICC 3.1 > 0.961 was found for the different load levels. Additionally, the criterion validity based on the Pearson correlation coefficient was R2 = 0.993 and the limits of agreement, expressed by the accuracy (systematic bias) and the precision (SD), was between +9.45 × 10−3 m−1 and −6.78 × 10−3 m−1 for all load levels. The new measuring system offers both good accuracy (1.33 × 10−3 m−1) and high precision (4.14 × 10−3 m−1). However, the results are based on quasi-static ski deformations, which means that a transfer into the field is only allowed to a limited extent since the scope of the curvature model has not yet been definitely determined. The high laboratory-related reliability and validity of our novel ski prototype featuring PyzoFlex® technology make it a potential candidate for on-snow application such as smart skiing equipment.

22 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Christoph ThorwartlChristoph Thorwartl
Christoph Thorwartl
Thomas StögglThomas Stöggl
Thomas Stöggl
WTWolfgang Teufl
Wolfgang Teufl
HHHelmut Holzer
Helmut Holzer
JKJosef Kröll
Josef Kröll
So far, no studies of material deformations (e.g., bending of sports equipment) have been performed to measure the curvature (w″) using an optoelectronic measurement system OMS. To test the accuracy of the w″ measurement with an OMS (Qualisys), a calibration profile which allowed to: (i) differentiates between three w″ (0.13˙ m−1, 0.2 m−1, and 0.4 m−1) and (ii) to explore the influence of the chosen infrared marker distances (50 mm, 110 mm, and 170 mm) was used. The profile was moved three-dimensional at three different mean velocities (vzero = 0 ms−1, vslow = 0.2 ms−1, vfast  = 0.4 ms−1) by an industrial robot. For the accuracy assessment, the average difference between the known w″ of the calibration profile and the detected w″ from the OMS system, the associated standard deviation (SD) and the measuring point with the largest difference compared to the defined w″ (=maximum error) were calculated. It was demonstrated that no valid w″ can be measured at marker distances of 50 mm and only to a limited extent at 110 mm. For the 170 mm marker distance, the average difference (±SD) between defined and detected w″ was less than 1.1 ± 0.1 mm−1 in the static and not greater than −3.8 ± 13.1 mm−1 in the dynamic situations. The maximum error in the static situation was small (4.0 mm−1), while in the dynamic situations there were single interfering peaks causing the maximum error to be larger (−30.2 mm−1 at a known w″ of 0.4 m−1). However, the Qualisys system measures sufficiently accurately to detect curvatures up to 0.13˙ m−1 at a marker distance of 170 mm, but signal fluctuations due to marker overlapping can occur depending on the direction of movement of the robot arm, which have to be taken into account.

30 October 2026
Verified
Conference Paper
Open access
TGThomas Grah
Thomas Grah
OJOliver Jung
Oliver Jung
ARAntoni Rayzhekov
Antoni Rayzhekov
Christoph ThorwartlChristoph Thorwartl
Christoph Thorwartl
TFThomas Finkenzeller
Thomas Finkenzeller
AMAlexander Meschtscherjakov
Alexander Meschtscherjakov