David Chiasson

Mr. David Chiasson

Shanghai Jiao Tong University
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in Journal of Biomechanics
Verified
Journal Article
Closed access
TTTian Tan
Tian Tan
David ChiassonDavid Chiasson
David Chiasson
HHHai Hu
Hai Hu
PSPeter Shull
Peter Shull

15 February 2023 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
David ChiassonDavid Chiasson
David Chiasson
YLYuan Lin
Yuan Lin
MKManon Kok
Manon Kok
PSPeter Shull
Peter Shull
Hyperbolic localization measures the time difference of arrivals (TDOAs) of signals to determine the location of a wireless source or receiver. Traditional methods depend on precise clock synchronization between nodes so that time measurements from independent devices can be meaningfully compared. Imperfect synchronization is often the dominant source of error. We propose two new message-based TDOA equations for hyperbolic localization which require no synchronization and meet or exceed state-of-the-art accuracy. Our approaches leverage anchor nodes that observe each other’s packet arrival times and a novel reformulation of the TDOA equation to reduce the effect of clock drift error. Closed-form equations are derived for computing TDOA in both self-localization and source-localization modes of operation along with bounds on maximum clock drift error. Three experiments are performed, including a clock drift simulation, a nonline-of-sight (NLOS) simulation, and an indoor validation experiment on custom ultra wideband (UWB) hardware all of which involved eight anchor nodes and one localizing node in a 128- $\text{m}^{3}$ capture volume. Our source-localization approach achieved unprecedented accuracy with lower cost equipment and trivial setup. Our self-localization matched state-of-the-art accuracy but with infinite scalability and high privacy. These results could enable economical and infinite density indoor navigation and dramatically reduce the economic cost and increase the accuracy of implementing industrial and commercial tracking applications.

22 March 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JMJonathan C. Maglott
Jonathan C. Maglott
David ChiassonDavid Chiasson
David Chiasson
PSPeter Shull
Peter Shull
Basketball players sometimes claim to know when their shot is good, even before it goes in. This is likely because shooter proprioception can help determine shot outcome, even before their eyes confirm it. This phenomenon, however, has not been systematically explored for collegiate and recreational shooters. This study compared how well collegiate shooters and recreational shooters could predict outcomes of their own free throws without seeing the shot result. Forty collegiate and recreational shooters shot standard free throws while wearing liquid-crystal occlusion glasses that activated to occlude vision immediately following ball release during each shot. After each shot, shooters verbally predicted shot outcome as “in” or “out”, and predicted results were compared with actual outcomes. As anticipated, for made shots, collegiate shooters more accurately predicted their own shots than recreational shooters. However, unexpectedly, for missed shots, collegiate shooters were worse than recreational shooters and were even significantly worse than chance. Further analysis found that collegiate shooters exhibited a significantly higher bias toward predicting their shots as “in”. Understanding how shooters of different skill levels perceive their own shot could inform future training strategies for improving shooter accuracy.

16 December 2020 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
BLBryndan W. Lindsey
Bryndan W. Lindsey
JXJunkai Xu
Junkai Xu
David ChiassonDavid Chiasson
David Chiasson
PSPeter Shull
Peter Shull
NCNelson Cortes
Nelson Cortes
Gait modifications are effective in reducing the first peak knee abduction moment (PKAM), a surrogate for knee loading. Reliance on 3D motion capture currently restricts these modifications to the laboratory. Therefore, our purpose was to test the feasibility of a novel wearable biofeedback system to train (1) toe-in and trunk lean modifications and (2) combined toe-in and trunk lean modifications to reduce PKAM during overground walking outside of the laboratory. Twelve healthy participants practiced modifications in a university hallway directly after performing five normal walking trials. The wearable feedback system provided real-time haptic biofeedback during training trials to inform participants if they were within the prescribed modification range (7–12 deg greater than baseline). Participants were instructed to move to the next modification only once they felt comfortable and could perform it with minimal errors. Following training, five trials of each modification were immediately performed in the gait laboratory without feedback. All participants successfully modified their foot progression and trunk angle using the wearable system. At post-test, PKAM decreased from baseline by 62%, 55%, and 28% during combined, trunk leanand toe-in gait, respectively. The wearable feedback system was effective to modify participants' foot and trunk angle by the prescribed amount, resulting in reduced PKAM during all modifications at post-test. Participants were also able to perform a combined modification, although it took longer to report feeling comfortable doing so. This study demonstrates that a wearable feedback system is feasible to modify kinematic parameters and train gait modifications outside the laboratory.

20 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
David ChiassonDavid Chiasson
David Chiasson
JXJunkai Xu
Junkai Xu
PSPeter Shull
Peter Shull
Real-time human movement inertial measurement unit (IMU) signals are central to many emerging medical and technological applications, yet few techniques have been proposed to process and represent this information modality in an efficient manner. In this paper, we explore methods for the lossless compression of human movement IMU data and compute compression ratios as compared with traditional representation formats on a public corpus of human movement IMU signals for walking, running, sitting, standing, and biking human movement activities. Delta coding was the highest performing compression method which compressed walking, running, and biking data by a factor of 10 and compressed sitting and standing data by a factor of 18 relative to the original CSV formats. Furthermore, delta encoding was shown to approach the a posteriori optimal linear compression level. All methods were implemented and released as open source C code using fixed point computation which can be integrated into a variety of computational platforms. These results could serve to inform and enable human movement data compression in a variety of emerging medical and technological applications.

2 June 2022 in IEEE Transactions on Human-Machine Systems
Verified
Journal Article
Closed access
David ChiassonDavid Chiasson
David Chiasson
PSPeter Shull
Peter Shull
Non-line-of-sight (NLoS) conditions are a known performance limiting factor in ultrawideband (UWB) ranging accuracy, particularly in environments with densely packed dynamically moving humans, i.e., crowds. As UWB technology is recently seeing wide deployment in consumer devices, the effects of NLoS conditions due to human body shadowing will greatly degrade the performance of related ranging and localization applications. We thus propose the round-robin ranging protocol, an extension of alternative double-sided two-way ranging, which scales well for high rate sampling of dense networks and further propose a cooperative statistical approach based on multidimensional scaling (MDS) to mitigate NLoS conditions. Experimental validation was performed in a densely packed dynamically moving human environment. Nine subjects walked naturally within a 16-m2 motion capture area while wearing UWB sensors at the foot, wrist, torso, and head and reflective optical motion capture markers. UWB accuracy of the 36 intersubject ranges was computed as the difference in range estimates between the UWB sensors and the optical motion capture system. Results showed that the proposed MDS approach reduced ranging accuracy errors by 11%, 13%, 16%, and 32% at the foot, wrist, torso, and head, respectively. Body placement had a significant effect on the ranging performance in that transceivers placed on the head and foot reduced ranging errors by 84% and 63% compared with the traditional torso placement. These results suggest that the proposed approaches could significantly improve the performance in UWB ranging applications involving human bodies such as human movement monitoring, athletics, logistics, and social contact tracing applications.