Peter Shull

Dr. Peter Shull

Mechanical Engineering, Shanghai Jiao Tong University

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2014 in Gait & Posture
Verified
Journal Article
Closed access
PSPeter Shull
Peter Shull
WJWisit Jirattigalachote
Wisit Jirattigalachote
MHMichael A. Hunt
Michael A. Hunt
MCMark R. Cutkosky
Mark R. Cutkosky
SDScott L. Delp
Scott L. Delp

7 May 2021 in IEEE Reviews in Biomedical Engineering
Verified
Journal Article
Closed access
SJShuo Jiang
Shuo Jiang
PKPeiqi Kang
Peiqi Kang
XSXinyu Song
Xinyu Song
BLBenny Lo
Benny Lo
PSPeter Shull
Peter Shull
Hands are vital in a wide range of fundamental daily activities, and neurological diseases that impede hand function can significantly affect quality of life. Wearable hand gesture interfaces hold promise to restore and assist hand function and to enhance human-human and human-computer communication. The purpose of this review is to synthesize current novel sensing interfaces and algorithms for hand gesture recognition, and the scope of applications covers rehabilitation, prosthesis control, exoskeletons for augmentation, sign language recognition, human-computer interaction, and user authentication. Results showed that electrical, mechanical, acoustical/vibratory, and optical sensing were the primary input modalities in gesture recognition interfaces. Two categories of algorithms were identified: 1) classification algorithms for predefined, fixed hand poses and 2) regression algorithms for continuous finger and wrist joint angles. Conventional machine learning algorithms, including linear discriminant analysis, support vector machines, random forests, and non-negative matrix factorization, have been widely used for a variety of gesture recognition applications, and deep learning algorithms have more recently been applied to further facilitate the complex relationship between sensor signals and multi-articulated hand postures. Future research should focus on increasing recognition accuracy with larger hand gesture datasets, improving reliability and robustness for daily use outside of the laboratory, and developing softer, less obtrusive interfaces.

20 July 2015 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
PSPeter Shull
Peter Shull
DDDana D. Damian
Dana D. Damian
Sensory impairments decrease quality of life and can slow or hinder rehabilitation. Small, computationally powerful electronics have enabled the recent development of wearable systems aimed to improve function for individuals with sensory impairments. The purpose of this review is to synthesize current haptic wearable research for clinical applications involving sensory impairments. We define haptic wearables as untethered, ungrounded body worn devices that interact with skin directly or through clothing and can be used in natural environments outside a laboratory. Results of this review are categorized by degree of sensory impairment. Total impairment, such as in an amputee, blind, or deaf individual, involves haptics acting as sensory replacement; partial impairment, as is common in rehabilitation, involves haptics as sensory augmentation; and no impairment involves haptics as trainer. This review found that wearable haptic devices improved function for a variety of clinical applications including: rehabilitation, prosthetics, vestibular loss, osteoarthritis, vision loss and hearing loss. Future haptic wearables development should focus on clinical needs, intuitive and multimodal haptic displays, low energy demands, and biomechanical compliance for long-term usage.

4 December 2017 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
SJShuo Jiang
Shuo Jiang
BLBo Lv
Bo Lv
WGWeichao Guo
Weichao Guo
CZChao Zhang
Chao Zhang
HWHaitao Wang
Haitao Wang
PSPeter Shull
Peter Shull
While most wearable gesture recognition approaches focus on the forearm or fingers, the wrist may a more suitable location for practical use. We present the design and validation of a real-time gesture recognition wristband based on surface electromyography (sEMG) and inertial measurement unit (IMU) sensing fusion, which can recognize 8 air gestures and 4 surface gestures with 2 distinct force levels. Ten healthy subjects performed an initial gesture recognition experiment, followed by a second experiment 1 hour later and a third experiment 1 day later. Classification accuracies for the initial experiment were 92.6% and 88.8% for air and surface gestures, respectively, and there were no changes in accuracy results during testing 1 hour and 1 day later (p>0.05). These results demonstrate the feasibility of wrist-based gesture recognition paving the way for potential future integration in to a smart watch or other wrist-worn wearable for intuitive human computer interaction.

1 July 2016 in Gait & Posture
Verified
Journal Article
Closed access
YHYangjian Huang
Yangjian Huang
JXJunkai Xu
Junkai Xu
BYBo Yu
Bo Yu
PSPeter Shull
Peter Shull

18 March 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
PSPeter Shull
Peter Shull
SJShuo Jiang
Shuo Jiang
YZYuhui Zhu
Yuhui Zhu
XZXiangyang Zhu
Xiangyang Zhu
This paper presents a new approach to wearable hand gesture recognition and finger angle estimation based on modified barometric pressure sensing. Barometric pressure sensors were encased and injected with VytaFlex rubber such that the rubber directly contacted the sensing element allowing pressure change detection when the encasing rubber was pressed. A wearable prototype consisting of an array of 10 modified barometric pressure sensors around the wrist was developed and validated with experimental testing for three different hand gesture sets and finger flexion/extension trials for each of the five fingers. Overall hand gesture recognition classification accuracy was 94%. Further analysis revealed that the most important sensor location was the underside of the wrist and that when reducing the sensor number to only 5 optimally placed sensors, classification accuracy was still 90%. For continuous finger angle estimation, aggregate R2 values between actual and predicted angles were thumb: 0.81±0.10, index finger: 0.85±0.06, middle finger: 0.77±0.08, ring finger: 0.77±0.12, and pinkie finger: 0.75±0.10, and the overall average was 0.79±0.05. These results demonstrate that a modified barometric pressure wristband can be used to classify hand gestures and to estimate individual finger joint angles. This approach could serve to improve clinical treatment for upper extremity deficiencies, such as for stroke rehabilitation, by providing objective patient motor control metrics to inform and aid physicians and therapists throughout the rehabilitation process.