Krystel Pélissier

Dr. Krystel Pélissier

French Corrosion Institute
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2020 in Coatings
Verified
Journal Article
Open access
PDF file
KPKrystel Pélissier
Krystel Pélissier
dominique thierrydominique thierry
dominique thierry
The constant change in coating technology and environmental regulations has led to the development of low-solvent to solvent-free organic coatings, such as powder and high-solid coatings. These two technologies are well developed, but are still not the preferred choice when considering anticorrosive coating for marine and offshore applications. This mostly arise from a lack of perspective in their long-term behavior and from the difficulty in their applications. This review’s principal aim is to describe powder and high-solid technologies from their formulation and application to their use in marine and offshore applications while recalling and giving key notions needed when the field of anticorrosive coatings is considered. First, the requirement for coatings to be called anticorrosive will be given alongside with their protection and failure mechanisms. The formulation and application for high-solid and powder coatings will be exposed followed by the description of the type of coating chemistry used in harsh environment. Finally, high-solid and powder coatings behavior in these types of environment will be discussed.

16 November 2022 in Coatings
Verified
Journal Article
Open access
PDF file
KPKrystel Pélissier
Krystel Pélissier
NLNathalie LeBozec
Nathalie LeBozec
dominique thierrydominique thierry
dominique thierry
NLNicolas Larché
Nicolas Larché
Anticorrosive coatings are widely used to protect steel against corrosion. Different standards exist to access the corrosion performance of anticorrosive paints. Among them, the so-called neutral salt spray test (NSST-ISO 9227) or cycling corrosion tests ISO 12944-6, ISO 12944-9, NACE TM0304, or NACE TM0404 can be named. It is well-known that some accelerated corrosion tests are not fully representative of the field exposure results. However, a lack in the literature exists correlating accelerated tests to field exposure, especially when long-term durations are considered. In this study, 11 different organic coatings have been investigated in terms of coating resistance to corrosion creep in two types of field exposure sites, namely a stationary site and an operating ship, and their performance was compared to two accelerated tests (ISO 12944-9 and modified ASTM D5894 standard). The results showed differences in the sites’ corrosivity and the coating systems’ performance as a function of the exposure sites. A lack of correlation exists between the ISO 12944-9 standard and the stationary site, due to the latter’s high corrosivity, while, to the contrary, a satisfying correlation with the operating ship was demonstrated; whereas, the modified ASTM D5894 standard showed a satisfying correlation with both types of sites.

1 June 2021 in Materials Letters
Verified
Journal Article
Closed access
FVFlavien Vucko
Flavien Vucko
MPM. Prestat
M. Prestat
LHLorenz Holzer
Lorenz Holzer
BTB. Tribollet
B. Tribollet
KPKrystel Pélissier
Krystel Pélissier
DTD. Thierry
D. Thierry

13 November 2017 in Materials and Corrosion
Verified
Journal Article
Closed access
PDF file
NLNathalie LeBozec
Nathalie LeBozec
DTDominique Thierry
Dominique Thierry
KPKrystel Pélissier
Krystel Pélissier

11 June 2021 in Coatings
Verified
Journal Article
Open access
PDF file
KPKrystel Pélissier
Krystel Pélissier
dominique thierrydominique thierry
dominique thierry
It is well known that the surface state (cleanliness, composition) of galvanized steel prior to the application of an organic coating is an important parameter. The surface state will affect the adhesion properties of the complete system and therefore will also impact its corrosion resistance and its tendency to blistering. Before the application of a pretreatment layer, galvanized steel strips are normally alkaline cleaned. This step is known to remove the native oxide film formed on hot dip galvanized steel after processing and appears as one of the most important steps to study the impact of the surface properties on the performance of painted systems. This study focused on making use of the cleaning step to input a variability on the surface composition (mainly surface concentration of aluminum) and evaluate its consequence(s) on the performance of a complete paint system. The results showed that, a variability in terms of surface aluminum concentration could be achieved by the cleaning step and that signs of performance improvement in terms of adhesion and tendency to blistering were spotted with a low content of aluminum at the surface.

24 September 2019 in ChemElectroChem
Verified
Journal Article
Closed access
PDF file
JCJosiane Soares Coasta
Josiane Soares Coasta
MPMichel Prestat
Michel Prestat
BLBenoit Lescop
Benoit Lescop
SRStephane Rioual
Stephane Rioual
BTBernard Tribollet
Bernard Tribollet
dominique thierrydominique thierry
dominique thierry