Jiu Zhang

Dr. Jiu Zhang


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GMGuohui Mei
Guohui Mei
HLHong Liu
Hong Liu
YLYingnan Li
Yingnan Li
JZJiu Zhang
Jiu Zhang
SZShumao Zhao
Shumao Zhao
Stelmor system is usually used to control cooling uniformity and rate of hot-rolled wire loops to obtain the desired mechanical properties. First of all, it is necessary to accurately measure the temperature distribution of wire loops. However, there are some shortcomings in the current methods due to the grid structure of overlapping wire loops. This paper proposes a new measurement method. The target region is captured dynamically based on the temperature distribution characteristics of the thermal image. The effective radiation between the wire loops is analyzed by building an effective emissivity model. The probability distribution test confirms the validity of the model. The temperature measurement experiment shows that the temperature data measured by our approach is more stable and accurate than those of current pyrometers. Anticipated results indicate the potential application in improving process technology. For example, the transverse temperature distribution curve obtained based on this approach can be used to guide the configuration of air volume during the cooling process of the wire loops to improve product quality.

25 September 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
AZAo Zhang
Ao Zhang
TZTongtong Zhao
Tongtong Zhao
GMGuohui Mei
Guohui Mei
SZShumao Zhao
Shumao Zhao
JZJiu Zhang
Jiu Zhang
The reflected radiation generated by the interreflection between the inner surfaces of cavity-like objects is not easy to measure directly and leads to temperature measurement errors. In this paper, the effect of reflected radiation on temperature measurement was described based on effective emissivity modeling, which does not require direct determination of reflected radiation. Based on different modeling principle, we proposed two methods to estimate the actual temperature of the inner surface by effective emissivity models and pyrometer measurements. Simulation calculation was designed to test the feasibility of both methods. Experiment was conducted to verify the proposed methods. Compared with conventional method, the proposed methods achieved an improved performance on inner surface temperature measurement, demonstrating a decline in the average error from 1.17% to 0.31% and 0.27%, respectively.

2 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
QXQixian Xie
Qixian Xie
JZJiu Zhang
Jiu Zhang
ZMZhizhong Mao
Zhizhong Mao
Pouring temperature of molten steel at the outlet of the tundish is the key parameter to control the solidification accurately. However, the stopper occupies the top of the outlet, leading to that the existing sensor cannot measure the molten steel temperature at the outlet. To solve the problem, this work develops a new small sensor installed at the bottom of the stopper, which combines the stopper and the temperature sensor into one. Mo-W-ZrO 2 cermet that has excellent corrosion resistance has been used to make a small sensor with a thin-walled structure of 5 mm thickness. To sense the pouring temperature independently, fast and accurately, the length/radius ratio of the small sensor should reach 13 to form a blackbody cavity approximately. According to the industrial test, the pouring temperature of molten steel is measured for the first time in the field of metallurgy. Meanwhile, a deviation (e.g., 8.2 °C or 1.4 °C) between the pouring temperature and the temperature measured by the existing sensor is found. As a result, based on the temperature measured by the existing sensor, the superheat of molten steel and the cooling water flow usually have enough margin for ensuring the safe operation of continuous casting, reducing the control accuracy of the solidification and increasing the risk of quality problems. Therefore, this work will be helpful to control the solidification more accurately, improving the product quality.

7 February 2023 in Ceramics International
Verified
Journal Article
Closed access
JZJiu Zhang
Jiu Zhang
XLXu Lan
Xu Lan
BYBaihui You
Baihui You
QXQixian Xie
Qixian Xie
GMGuohui Mei
Guohui Mei

15 April 2022 in ISIJ International
Verified
Journal Article
Open access
PDF file
JZJiu Zhang
Jiu Zhang
QXQixian Xie
Qixian Xie
GMGuohui Mei
Guohui Mei
ZMZhizhong Mao
Zhizhong Mao
Mo–W–ZrO2 cermet, which is usually sintered in H2, has been used for molten steel temperature sensor. However, the crack caused by water vapor during its sintering limits the industrial application. Thus, the mechanism of crack formation has been investigated. Cracks are mainly caused by a significant volume expansion which is attributed to that the metal powders of the green body of cermet are oxidized by water vapor. The obvious expansion of approximately 17% in diameter occurs below 1200°C, reducing the bonding strength. Meanwhile, the support frame for the sintering restricts the expansion. Both of them are the main reasons for the crack formation. At higher temperature, the volume of above oxidized metal powders decreases caused by the reduction of H2. The volume of the metal powders increases first and then decreases, which leads to a more difficult sintering densification. Moreover, the ceramic powders are sintered earlier and form a skeleton. As a result, the sintering densification is restrained and the pores form. As the water vapor is eliminated through the H2 filling and pumping vacuum, the problems of cracks and pores are addressed, which is helpful to solve the main contradiction in industrial application of the Mo–W–ZrO2 sensor.

1 August 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
TZTongtong Zhao
Tongtong Zhao
AZAo Zhang
Ao Zhang
GMGuohui Mei
Guohui Mei
SZShumao Zhao
Shumao Zhao
JZJiu Zhang
Jiu Zhang
Blackbody cavity temperature sensor has been used in the field of radiation temperature measurement since its applicability in measuring the temperature of a liquid. A detector is always placed coaxially with the cavity to receive the radiant energy from the bottom of the cavity, where the temperature is the same as the liquid to be measured. However, the accuracy problem still exists. Due to the deviation of the sensor’s relative position, there is a deviation angle between the axis of the detector and of the cavity, which will cause the detector receives the radiation from the low radiant energy regions of the measuring cavity and lead to a low precision of the measurement result. In this article, research is made to analyze the effects of the misalignment between the cavity and the detector as well as the influence of the length of isothermal zone and spot size when the detector is out of the axis. To verify the situations above, we set experiments that reference the actual conditions, and results show good agreement with theoretical analysis. The results are helpful for the optimum parameter design of the blackbody cavity as well as determine the relative position of the detector and the cavity.