Sébastien BAU

Dr. Sébastien BAU

Institut National de Recherche et de Sécurité (INRS)
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2019 in Toxicology and Applied Pharmacology
Verified
Journal Article
Closed access
LGLaurent Gaté
Laurent Gaté
KKKristina Bram Knudsen
Kristina Bram Knudsen
CSCarole Seidel
Carole Seidel
TBTrine Berthing
Trine Berthing
LCLaëtitia CHEZEAU
Laëtitia CHEZEAU
FCFrédéric Cosnier
Frédéric Cosnier

1 December 2017 in Science of The Total Environment
Verified
Journal Article
Closed access
ATAna Maria Todea
Ana Maria Todea
SBStefanie Beckmann
Stefanie Beckmann
HKHeinz Kaminski
Heinz Kaminski
DBDelphine Bard
Delphine Bard
SBSébastien BAU
Sébastien BAU
CAChristof Asbach
Christof Asbach

1 June 2010 in Powder Technology
Verified
Journal Article
Closed access
SBSébastien BAU
Sébastien BAU
OWO. Witschger
O. Witschger
FGF. Gensdarmes
F. Gensdarmes
ORO. Rastoix
O. Rastoix
DTDominique Thomas
Dominique Thomas

1 December 2018 in Journal of Aerosol Science
Verified
Journal Article
Closed access
SBSoleiman Bourrous
Soleiman Bourrous
QRQuentin Ribeyre
Quentin Ribeyre
LLLaura Lintis
Laura Lintis
JYJérôme Yon
Jérôme Yon
SBSébastien BAU
Sébastien BAU
FOFrançois-Xavier Ouf
François-Xavier Ouf

12 December 2019 in Journal of Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
SBSébastien BAU
Sébastien BAU
DRDavy Rousset
Davy Rousset
RPRaphaël Payet
Raphaël Payet
FKFrançois-Xavier Keller
François-Xavier Keller
This study aims to characterize airborne particles emitted from a metal additive manufacturing machine and related levels of occupational exposure. To achieve this, a complete measurement methodology was deployed around a direct energy deposition machine. Different operating conditions were investigated, based on configurations of two materials and two injection nozzles. Two replicates were performed for each condition. Airborne particles emitted during repeated manufacturing cycles were measured simultaneously at the source, in the near field, in the far field and on the operator. Real-time instruments were used to characterize the machine emissions (10 nm–10 µm) associated with respirable and inhalable samplers and cascade impactors. Measurements were made during both the manufacturing process and transient operating phases. In parallel, personal exposure to hexavalent chromium was assessed. The number of particles measured for the different machining phases show that high levels of particles (> 5 × 105 # cm−3, 0.3–1.3 mg m−3 inhalable particles, 0.2–6 µg m−3 CrVI) were emitted in the machine enclosure. The size distributions indicate that more than 90% of the particles are smaller than 250 nm. Occupational exposure to CrVI was found to be below the LOQ of 0.098 µg m−3 for the two alloys investigated. During the machining process, near-field number and mass concentrations were ∼ 104 # cm−3, and below 0.04 mg m−3, respectively. Far-field number concentrations were also on the order of 104 # cm−3 throughout the whole monitoring period. The transient phase of door opening was found to result in high levels of exposure (> 105 # cm−3), which were also detected in the near-field, confirming the need to implement preventative actions. To address this issue, a collective protective measure, consisting of setting a time delay of about 8 min between the end of the manufacturing process and opening of the door, could be employed. This collective measure should also be accompanied by the wearing of personal protective equipment by the operator when an intervention in the machine enclosure is necessary.

27 April 2014 in Journal of Nanoparticle Research
Verified
Journal Article
Closed access
PDF file
ACAugustin Charvet
Augustin Charvet
SBSébastien BAU
Sébastien BAU
NCNatalia Estefania Paez Coy
Natalia Estefania Paez Coy
DBDenis Bémer
Denis Bémer
DTDominique Thomas
Dominique Thomas