Hayden Carlton

Dr. Hayden Carlton

Biomedical Engineering, University of Memphis, Memphis, Florida, USA
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
DCDavid A. Castilla-Casadiego
David A. Castilla-Casadiego
Hayden CarltonHayden Carlton
Hayden Carlton
DGDavid Gonzalez-Nino
David Gonzalez-Nino
KMKatherine A. Miranda-Muñoz
Katherine A. Miranda-Muñoz
RDRaheleh Daneshpour
Raheleh Daneshpour
JAJorge Almodovar
Jorge Almodovar

9 May 2022 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
AEAsif Imran Emon
Asif Imran Emon
Hayden CarltonHayden Carlton
Hayden Carlton
JHJohn Harris
John Harris
AKAlexis Krone
Alexis Krone
MHMustafeez Ul Hassan
Mustafeez Ul Hassan
AMAlan Mantooth
Alan Mantooth
Gallium nitride (GaN) high electron mobility transistors (HEMTs) are excellent power semiconductor devices due to their superior material properties compared to their silicon (Si) counterparts. It has demonstrated a fast switching speed with high dV/dt, enabling the designer to push the switching frequency toward the MHz range. However, traditional wire-bonded packaging becomes a limiting factor in fully harnessing the benefits offered by these advanced power devices, as it is likely to introduce voltage overshoot, oscillation, parasitic turn-on, and electromagnetic interference (EMI) issues; thus, improved and advanced packaging structures are a must to bridge the gap. Besides, the unique electrical behavior and footprint of GaN compared to Si and Si carbide make them have different requirements for power module integration. To seek a viable solution, a globally optimized double-sided cooled, gate driver integrated 650-V/60-A GaN half-bridge power module is presented herein. The proposed 3-D integrated hybrid solution delivers an optimized package, having power loop inductance and thermal resistance as low as 0.91 nH and $0.38~^{\circ }\text{C}$ /W, respectively, which is verified using simulation and experimental results. The overall utility of the design improved proportionately by introducing simple, yet effective electrical/thermal codesign approaches, which can be applied to future power modules, designed for separate applications.

29 August 2020 in Lubricants
Verified
Journal Article
Open access
PDF file
Hayden CarltonHayden Carlton
Hayden Carlton
DHDavid Huitink
David Huitink
Hong LiangHong Liang
Hong Liang
While reactions driven by mechanical force or stress can be labeled mechanochemical, those specifically occurring at a sliding interface inherit the name tribochemical, which stems from the study of friction and wear: tribology. Increased perception of tribochemical reactions has been gained through technological advancement, and the development of new applications remains on-going. This surprising physico-kinetic process offers great potential in novel reaction pathways for synthesis techniques and nanoparticle interactions, and it could prove to be a powerful cross-disciplinary research area among chemists, engineers, and physicists. In this review article, a survey of the history and recent usage of tribochemical reaction pathways is presented, with a focus on forging new compounds and materials with this sustainable synthesis methodology. In addition, an overview of tribochemistry’s current utility as a synthesis pathway is given and compared to that of traditional mechanochemistry.

21 May 2020 in Journal of Electronic Packaging
Verified
Journal Article
Closed access
PDF file
Hayden CarltonHayden Carlton
Hayden Carlton
DPDustin Pense
Dustin Pense
DHDavid Huitink
David Huitink
Due to the inherently low adhesive strength and structural integrity of polymer thermal interface materials (TIMs), they present a likely point of failure when succumbed to thermomechanical stresses in electronics packaging. Herein, we present a methodology to quantify TIM degradation through an accelerated and repeatable mechanical cycling technique. The testing apparatus incorporated a steady-state thermal conductivity measurement system, consistent with ASTM 5470-06, with added displacement actuation and force sensing to provide controlled cyclic loading between −20 N and 20 N. Additionally, a novel optical technique was utilized to observe void formation, pump-out, and dry-out behavior during cycling, in order to correlate the thermal performance with physical behaviors of different TIMs under cyclic stress. Of the two different pastes analyzed, cyclic testing was found to degrade the thermal performance of the less viscous TIM by increasing its interfacial resistance. Optical qualitative measurements revealed the breakdown of the TIM structure at the interface, which indicated the formation of voids due to TIM degradation. Applying this testing method for future TIM development could help in optimizing TIM structure for particular package applications.

27 January 2023 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
Hayden CarltonHayden Carlton
Hayden Carlton
Robert IvkovRobert Ivkov
Robert Ivkov
Heating magnetic nanoparticles (MNPs) with alternating magnetic fields (AMFs) have applications in biomedical research and cancer therapy. Accurate measurement of the heating efficiency or specific loss power (SLP) generated by the MNPs is essential to assess response(s) in biological systems. Efforts to develop standardized equipment and to harmonize results obtained from various MNP samples and AMF systems have met with little success. Without a standardized magnetic nanoparticle or calorimeter device, objective comparisons of estimated thermal output among laboratories remain a challenge. In addition, the most widely used adiabatic initial slope model fails to account for thermal losses, which are unavoidable. We propose a non-adiabatic method to analyze MNP heating efficiency derived from the Box–Lucas equation, wherein the sample is subjected to several short duration heating pulses. SLP is then estimated from an arithmetic average of the Box–Lucas fitted coefficients obtained from each pulse. Heating experiments were conducted with two identical samples that were placed within vessels having different thermal insulation using the same AMF parameters. Though the samples generated different temperature curves, the pulsed Box–Lucas method produced nearly equivalent SLP estimates. Further, the pulsed test enabled analysis of the heat transfer coefficient providing quantitative measures of sample heat loss throughout the test, with robust statistical confidence. We anticipate this new methodology will aid efforts to standardize measurements of MNP heating efficiency, enabling direct comparison among varied systems.

20 June 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Hayden CarltonHayden Carlton
Hayden Carlton
Nageshwar ArepallyNageshwar Arepally
Nageshwar Arepally
SHSean Healy
Sean Healy
ASAnirudh Sharma
Anirudh Sharma
SPSarah Ptashnik
Sarah Ptashnik
Robert IvkovRobert Ivkov
Robert Ivkov
Magnetic particle hyperthermia (MPH) enables the direct heating of solid tumors with alternating magnetic fields (AMFs). One challenge with MPH is the unknown particle distribution in tissue after injection. Magnetic particle imaging (MPI) can measure the nanoparticle content and distribution in tissue after delivery. The objective of this study was to develop a clinically translatable protocol that incorporates MPI data into finite element calculations for simulating tissue temperatures during MPH. To verify the protocol, we conducted MPH experiments in tumor-bearing mouse cadavers. Five 8–10-week-old female BALB/c mice bearing subcutaneous 4T1 tumors were anesthetized and received intratumor injections of Synomag®-S90 nanoparticles. Immediately following injection, the mice were euthanized and imaged, and the tumors were heated with an AMF. We used the Mimics Innovation Suite to create a 3D mesh of the tumor from micro-computerized tomography data and spatial index MPI to generate a scaled heating function for the heat transfer calculations. The processed imaging data were incorporated into a finite element solver, COMSOL Multiphysics®. The upper and lower bounds of the simulated tumor temperatures for all five cadavers demonstrated agreement with the experimental temperature measurements, thus verifying the protocol. These results demonstrate the utility of MPI to guide predictive thermal calculations for MPH treatment planning.