Pedro Barreiros

Dr. Pedro Barreiros

Oral Rehabilitation, UNIPRO – Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, Gandra, Portugal
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2021 in Polymers
Verified
Journal Article
Open access
PDF file
António Sérgio SilvaAntónio Sérgio Silva
António Sérgio Silva
ACAurora Carvalho
Aurora Carvalho
Pedro BarreirosPedro Barreiros
Pedro Barreiros
JSJuliana de Sá
Juliana de Sá
Carlos ArosoCarlos Aroso
Carlos Aroso
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
Thermal and self-curing acrylic resins are frequently and versatilely used in dental medicine since they are biocompatible, have no flavor or odor, have satisfactory thermal qualities and polishing capacity, and are easy and fast. Thus, given their widespread use, their fracture resistance behavior is especially important. In this research work, we comparatively analyzed the fracture resistance capacity of thermo and self-curing acrylic resins in vitro. Materials and Methods: Five prosthesis bases were created for each of the following acrylic resins: Lucitone®, ProBase®, and Megacryl®, which were submitted to different forces through the use of the CS® Dental Testing Machine, usually mobilized in the context of fatigue tests. To this end, a point was defined in the center of the anterior edge of the aforementioned acrylic resin bases, for which the peak tended until a fracture occurred. Thermosetting resins were, on average, more resistant to fracture than self-curable resins, although the difference was not statistically significant. The thermosetting resins of the Lucitone® and Probase® brands demonstrated behavior that was more resistant to fracture than the self-curing homologues, although the difference was not statistically significant. Thermosetting resins tended to be, on average, more resistant to fracture and exhibited the maximum values for impact strength, compressive strength, tensile strength, hardness, and dimensional accuracy than self-curing resins, regardless of brand.

24 December 2020 in Journal of Periodontal Research
Verified
Journal Article
Closed access
PDF file
Pedro BarreirosPedro Barreiros
Pedro Barreiros
JBJoão Braga
João Braga
RFRicardo Faria-Almeida
Ricardo Faria-Almeida
CCCristina Coelho
Cristina Coelho
WTWim Teughels
Wim Teughels
Júlio C. M. SouzaJúlio C. M. Souza
Júlio C. M. Souza

15 June 2022 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
VCVitória Costa
Vitória Costa
António Sérgio SilvaAntónio Sérgio Silva
António Sérgio Silva
RCRosana Costa
Rosana Costa
Pedro BarreirosPedro Barreiros
Pedro Barreiros
Joana Silva MendesJoana Silva Mendes
Joana Silva Mendes
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
With continuing technological developments, there have been advances in the field of fixed prosthetics, particularly in impression-taking techniques. These technological advances mean that a wide variety of diagnostic and/or rehabilitation possibilities can be explored without the need for physical models. The aim of this study was to evaluate the accuracy of three intraoral scanners used in oral implant rehabilitation using an extraoral scanner as a reference and varying the scanning area. Three models representing different clinical scenarios were scanned 15 times by each intraoral scanner and three times by the extraoral scanner. The readings were analyzed and overlaid using engineering software (Geomagic® Control X software (Artec Europe, Luxembourg)). Statistically significant differences in accuracy were found between the three intraoral scanners, iTero® (Align Technology Inc., San Jose, CA, USA), Medit® (Medit®: Seoul, Korea), and Planmeca® (Planmeca®: Helsinki, Finland). In all clinical scenarios, the iTero® scanner had the best trueness (24.4 μm), followed by the Medit® (26.4 μm) and Planmeca® (42.1 μm). The Medit® showed the best precision (18.00 μm) followed by the iTero® (19.20 μm) and Planmeca® (34.30 μm). We concluded that the iTero® scanner had the highest reproducibility and accuracy in the clinical setting.

26 April 2022 in Polymers
Verified
Journal Article
Open access
PDF file
Joana Silva MendesJoana Silva Mendes
Joana Silva Mendes
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
Pedro BarreirosPedro Barreiros
Pedro Barreiros
Carlos ArosoCarlos Aroso
Carlos Aroso
António Sérgio SilvaAntónio Sérgio Silva
António Sérgio Silva
(1) Introduction: Denture adhesives (DAs) promote stability, chewing ability, and quality of life. The objective of this study was to compare the effectiveness of original brand DAs and white brands in their retention of conventional complete dentures. (2) Methods: This study followed the recommendations of the international standard ISO 10873. Three original brands of DA (Corega® Fixação 3D, GlaxoSmithKline®, Stafford Miller Ltd., Dungarvan Co. Waterford, Ireland), KuKident® Pro Procter & Gamble Technical Centres®, Ltd., Whitehal Lane, Germany and Elgydium® Fix, Laboratórios URGO® SL, Florida, Spain) were compared to three white brands (Fixação Extra Forte Pingo Doce®, Laboratórios Cosmodent®, Cantabria, Spain), Fixador de Próteses (Continente®, Propack®,Gmbh, Ladenburg, Germany) and Creme Fixador de Próteses (Auchan®, Ellipse®, Roubaix, France). Their retention capacities were analyzed using a mechanical test device. (3) Results: The mean retentive ability of original brand adhesives (M = 11.16, SD = 5.27) was significantly higher (t(298) = 11.88; p < 0.001) than that of the white brands (M = 5.92, SD = 1.18). When comparing all brands, statistically significant differences were also observed, F(5.294) = 707.68 (p < 0.001). The generic adhesive results were more homogeneous. The generic brands from Continente® (M = 5.24, SD = 0.94) and Auchan® (M = 5.80, SD = 0.79) were not significantly different, while the Pingo Doce® brand obtained significantly higher mean retention results (M = 6.71, SD = 1.28). (4) Conclusions: The original brands of DA have a significantly higher retentive ability than the white brands. Elygidim® Fix had the worst result of the three original brands, and the product from Pingo Doce® had the best result among the three white brands.

14 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
PBPedro Colaço Botelho
Pedro Colaço Botelho
JMJoana Silva Mendes
Joana Silva Mendes
Pedro BarreirosPedro Barreiros
Pedro Barreiros
Carlos ArosoCarlos Aroso
Carlos Aroso
António Sérgio SilvaAntónio Sérgio Silva
António Sérgio Silva
Temporary restorations play a fundamental role in oral rehabilitation. They can be used on teeth or implants for a variable period of time during the period prior to rehabilitation with definitive restorations. Temporary or provisional restorations manufactured via CAD/CAM methods are becoming increasingly used in the intermediate phase of the treatment of complex cases. The main objective of this study was to compare the fracture resistance of three materials used in the creation of provisional crowns on implants: polymethyl methacrylate (PMMA), composite resin, and polyether ether ketone (PEEK). Fracture resistance in PMMA (Zirkonzahn Temp Basic® , Gais, South Tyrol, Italy) ranged from 1216.0 N to 1461.2 N, with a mean of 1300.4 N (SD = 97.09). In the composite material (3M Lava Ultimate®, Minnesota, USA), fracture resistance varied between 1343.5 N and 1490.6 N, with a mean of 1425.9 N (SD = 49.03). Lastly, in PEEK (Tecno Med Mineral®, Zirkonzahn®, Gais, South Tyrol, Italy), fracture resistance ranged from 2294.8 N to 2451.7 N, with a mean of 2359.5 (SD = 50.01). The crowns made with the PEEK Tecno Med Mineral® (Zirkonzahn®, Tyrol, Italy) material presented the best fracture resistance, followed by the crowns made with the Lava Ultimate® (3M® ESPE, Minnesota, USA) composite resin material and, finally, those made with the PMMA Temp Basic® (Zirkonzahn®, Tyrol, Italy) material.

15 August 2023 in Polymers
Verified
Journal Article
Open access
PDF file
OROriana Caldeira Ribera
Oriana Caldeira Ribera
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
Joana Silva MendesJoana Silva Mendes
Joana Silva Mendes
Pedro BarreirosPedro Barreiros
Pedro Barreiros
Carlos ArosoCarlos Aroso
Carlos Aroso
António Sérgio SilvaAntónio Sérgio Silva
António Sérgio Silva
Implant-supported provisional restorations are critical for improving the esthetics and shaping of the peri-implant tissue. The mechanical properties of these provisional materials can be influenced by saliva, food, beverages, and interactions between these materials in the oral environment. Therefore, the integrity of provisional restorations should be preserved throughout the treatment period. This study aimed to evaluate the fracture strength of implant-supported polymethyl methacrylate (PMMA) provisional restorations made of computer-aided design and computer-aided manufacturing when immersed in different solutions at a controlled temperature of 37 °C for 7 days. Each analog-pillar-crown set was submerged in different liquids: 10 pieces were placed in distilled water then in tea, coffee, red wine, and Coca Cola® for 1 week at a controlled oral temperature of 37 °C. The samples were then subjected to fracture forces. The moment of fracture of the crown was recorded and compared with those of the other samples. Specimens immersed in distilled water (control group) had the highest fracture resistance (mean [M] = 1331.00 ± 296.74 N), while those immersed in tea had the lowest mean resistance to fracture (mean [M] = 967.00 ± 281.86 N). Nutritional deficiency and inappropriate eating habits influence the fracture strength of temporary crowns, thereby rendering them more elastic or less resistant to fractures.