Lluis Monjo

Dr. Lluis Monjo

Department of Industrial Systems and Design, Universidad Jaume I, 12071 Castellon de la Plana, Spain
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
JPJoaquin Pedra
Joaquin Pedra
Luis Sainz-SaperaLuis Sainz-Sapera
Luis Sainz-Sapera
Lluis MonjoLluis Monjo
Lluis Monjo
Multi-terminal high voltage direct current (HVDC) systems, together with AC transmission systems and voltage source converters (VSCs), form hybrid AC/DC grids with complex dynamic and transient interactions. VSCs characterization taking into account DC- and AC-side dynamics in order to study these interactions is not yet well solved. This paper presents a three-port transfer admittance-based matrix model of VSCs that can be applied for such purpose. It is derived from dq-complex space vectors and characterizes both AC- and DC-side dynamics by relating AC- and DC-side current and voltages in a three-dimensional admittance transfer matrix which considers the VSC outer control loops. The paper also proposes a systematical procedure for studying multi-terminal HVDC hybrid AC/DC transmission grids by the Norton admittance method, where the proposed VSC model can be easily included in the Norton admittance matrix. This procedure allows the study of grid dynamics using impedance-based stability criteria. The proposed model and procedure are applied to a stability study in a multi-terminal HVDC hybrid AC/DC transmission grid. PSCAD/EMTDC simulations are used to validate the application.

5 November 2014 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Open access
Lluis MonjoLluis Monjo
Lluis Monjo
HKHengameh Kojooyan-Jafari
Hengameh Kojooyan-Jafari
FCFelipe Córcoles-López
Felipe Córcoles-López
JPJoaquin Pedra
Joaquin Pedra
This paper presents a method for squirrel-cage induction motor parameter estimation using a phase-to-phase standstill variable frequency test. The measured resistance and reactance at different frequencies are the data of the minimization error function to be minimized for single- and double-cage model parameters estimation. It is observed that the single-cage model is unable to fit the measured data for frequencies above several tenths of Hertz, whereas the double-cage model fits the measured data accurately in all the frequency ranges (from 0 to 150 Hz). The single- and double-cage estimated parameters are validated by comparison with data from two additional tests: 1) steady-state torque and current measurement test at different speeds; and 2) dynamic free-acceleration test. Again, the agreement between measured and predicted torque (in the first test) and current (in both tests) is satisfactory only for the double-cage model.

24 May 2017 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Open access
Luis Sainz-SaperaLuis Sainz-Sapera
Luis Sainz-Sapera
Marc Cheah MañéMarc Cheah Mañé
Marc Cheah Mañé
Lluis MonjoLluis Monjo
Lluis Monjo
JLJun LIANG
Jun LIANG
Oriol Gomis-BellmuntOriol Gomis-Bellmunt
Oriol Gomis-Bellmunt
Resonance instabilities in power systems can be assessed with the positive-net-damping stability criterion. This criterion is a review of the complex torque coefficients method, but it does not provide the frequency of the closed-loop oscillatory modes. This paper presents an alternative approach of the positive-net-damping stability criterion to analyze electrical resonance instability. In this approach, resonance instabilities are identified in feedback systems derived from impedance-based equivalent circuits. The proposed approach is used to characterize the frequency of closed-loop oscillatory modes and identify the physical and control parameters of the system that increase or reduce the damping of these modes. The extension of the proposed approach to study the stability of single-input single-output and multiple-input multiple-output feedback systems is analyzed, and the approach is also compared with other stability methods in the literature. An example of an offshore wind power plant illustrates the theoretical study and compares the proposed approach with different methods to evaluate stability. Time-domain simulations in Power System Computer Aided Design/Electro Magnetic Transient Design and Control (PSCAD/EMTDC) are shown to validate the stability study.

1 June 2014 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
HKHengameh Kojooyan-Jafari
Hengameh Kojooyan-Jafari
Lluis MonjoLluis Monjo
Lluis Monjo
FCFelipe Córcoles-López
Felipe Córcoles-López
JPJoaquín Pedra
Joaquín Pedra
A new method for determination of the steady-state equivalent circuit parameters of wound-rotor induction motors using experimental data from starting transient measurements is presented. The algorithm data are the stator currents and voltages and mechanical speed. The algorithm uses the least-square method and motor dynamic equations in the synchronous reference frame. Moreover, an approximation of the rotor flux that improves the accuracy of the estimation method, as well as a detailed study of errors, is included. The estimation method is applied to starting transient measurement data of a 2 kW wound rotor induction motor, and the accuracy of the obtained parameters is verified by comparing steady-state torque- and current-slip curves calculated with the estimated parameters and those measured in the laboratory.

1 February 2017 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
Luis Sainz-SaperaLuis Sainz-Sapera
Luis Sainz-Sapera
Lluis MonjoLluis Monjo
Lluis Monjo
JPJoaquin Pedra
Joaquin Pedra
Marc Cheah MañéMarc Cheah Mañé
Marc Cheah Mañé
JLJun LIANG
Jun LIANG
Oriol Gomis-BellmuntOriol Gomis-Bellmunt
Oriol Gomis-Bellmunt
Wind turbine harmonic emissions due to power electronics are a well‐known power quality concern in wind power plants (WPPs). This problem may be increased by resonances because they amplify harmonic distortion around resonance frequencies. Hence, the resonance phenomenon is widely analysed in the literature. Resonance studies usually consider wind turbines (WTs) as ideal current sources, which can lead to inaccurate results. The study explores the effect of WT converter control on WPP harmonic response. It contributes expressions of WT equivalent harmonic impedance including current control of the grid side converter. This impedance allows WT converter control to be considered in WPP modelling to analyse its effect on harmonic response and resonances. PSCAD and Matlab/Simulink simulations were performed to validate the analytical expressions and illustrate the usefulness of the work in predicting harmonic distortions at WT terminals in actual WPPs.

19 September 2012 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
LSLuis Sainz
Luis Sainz
Lluis MonjoLluis Monjo
Lluis Monjo
SRSara Riera
Sara Riera
JPJoaquín Pedra
Joaquín Pedra
Traction systems are single-phase, nonlinear loads, which can unbalance and pollute supply voltages. To reduce voltage unbalance, reactances are usually connected in delta configuration with traction systems. This setup is called the Steinmetz circuit. Parallel and series resonances can occur between the Steinmetz capacitor and system inductors, increasing voltage distortion. Thus, it is important to analyze the parallel resonance “observed” from the traction system to avoid harmonic problems due to its injected harmonic currents. This paper studies this resonance analytically and presents simple expressions to locate it. Experimental measurements are also provided to validate the obtained analytical results. These expressions are also used to analyze resonance in several power systems in the literature.