Se-Won Park

Se-Won Park

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
SPSe-Won Park
Se-Won Park
YCYong-Do Choi
Yong-Do Choi
DLDu-Hyeong Lee
Du-Hyeong Lee
Park SW, et al. J Adv Prosthodont. 2020 Jun;12(3):107-113. https://doi.org/10.4047/jap.2020.12.3.107

SPSe-Won Park
Se-Won Park
RYRa Gyoung Yoon
Ra Gyoung Yoon
HLHyunwoo Lee
Hyunwoo Lee
Heon-Jin LeeHeon-Jin Lee
Heon-Jin Lee
YCYong-Do Choi
Yong-Do Choi
DLDu-Hyeong Lee
Du-Hyeong Lee
In cone-beam computed tomography (CBCT), the minimum threshold of the gray value of segmentation is set to convert the CBCT images to the 3D mesh reconstruction model. This study aimed to assess the accuracy of image registration of optical scans to 3D CBCT reconstructions created by different thresholds of grey values of segmentation in partial edentulous jaw conditions. CBCT of a dentate jaw was reconstructed to 3D mesh models using three different thresholds of gray value (−500, 500, and 1500), and three partially edentulous models with different numbers of remaining teeth (4, 8, and 12) were made from each 3D reconstruction model. To merge CBCT and optical scan data, optical scan images were registered to respective 3D reconstruction CBCT images using a point-based best-fit algorithm. The accuracy of image registration was assessed by measuring the positional deviation between the matched 3D images. The Kruskal–Wallis test and a post hoc Mann–Whitney U test with Bonferroni correction were used to compare the results between groups (α = 0.05). The correlations between the experimental factors were calculated using the two-way analysis of variance test. The positional deviations were lowest with the threshold of 500, followed by the threshold of 1500, and then −500. A significant interaction was found between the threshold of gray values and the number of remaining teeth on the registration accuracy. The most significant deviation was observed in the arch model with four teeth reconstructed with a gray-value threshold of −500. The threshold for the gray value of CBCT segmentation affects the accuracy of image registration of optical scans to the 3D reconstruction model of CBCT. The appropriate gray value that can visualize the anatomical structure should be set, especially when few teeth remain in the dental arch.