BACKGROUND AND PURPOSE: According to recent research, modern MR imaging can detect the presense of abnormalities on labyrinthine. Our aim was to report the patterns and prognostic role of abnormal findings on labyrinthine imaging in patients with sudden sensorineural hearing loss. MATERIALS AND METHODS: This study comprised 113 patients who were diagnosed with unilateral sudden sensorineural hearing loss and underwent 3T MR imaging, including pre-/postcontrast 3D fluid-attenuated inversion recovery and T1-weighted imaging. We analyzed abnormalities on MR imaging and correlated them with audiometric results. RESULTS: Thirty-one (27%) patients showed abnormal findings on labyrinthine MR imaging in the affected ear. The initial/final hearing levels of the MRI+ group (91 ± 25/73 ± 27 dB hearing loss) were significantly worse than those of the MRI– group (69 ± 30/48 ± 24 dB hearing loss). The incidence of abnormalities on labyrinthine MR imaging was significantly lower (3 of 40, 8%) in 40 patients with initial mild-to-moderate hearing loss than in those with profound hearing loss (16 of 34, 47%). Considering hearing improvement by the Siegel criteria, the rate of complete or partial recovery was significantly higher in the MRI– group (34%) than in the MRI+ group (10%). In patients with initial severe or profound hearing loss, the MRI– group showed greater hearing improvement (38 ± 21 dB) than the MRI+ group (23 ± 22 dB). CONCLUSIONS: Abnormalities on labyrinthine MR imaging were found in 27% of patients with sudden sensorineural hearing loss. The initial hearing loss was worse in the MRI+ group than in the MRI– group. In patients with initial severe and profound hearing loss, the presence of abnormalities on labyrinthine MR imaging indicated a poor prognosis.
Purpose: The aim of this multicenter study was to investigate the malignancy risk of minimally cystic thyroid nodules (MCTNs) using cyto-histopathologic diagnoses as the reference standard.Methods: From June 2015 to September 2015, 5,601 thyroid nodules (≥1 cm) from 4,989 consecutive patients who underwent thyroid ultrasonography (US) at 26 institutions were retrospectively analyzed. Each thyroid nodule was categorized according to its cystic proportion: purely solid, minimally cystic (≤10%), and partially cystic (>10%). The malignancy risk of MCTNs was compared with those of purely solid nodules and partially cystic thyroid nodules (PCTNs). The malignancy risk of MCTNs was assessed according to echogenicity and the presence of suspicious US features.Results: The prevalence of MCTNs was 22.5%. The overall malignancy risk of MCTNs was 8.8%, which was significantly lower than that of purely solid nodules (29.5%) (P0.05). MCTNs were associated with a higher risk of malignancy in hypoechoic nodules than in isohyperechoic nodules and in nodules with suspicious US features than in those without suspicious US features (all P<0.001).Conclusion: The malignancy risk of MCTNs was significantly lower than that of purely solid nodules. MCTNs could be categorized as PCTNs rather than as solid nodules to increase the accuracy of the risk stratification system for thyroid nodules.
Various risk stratification systems show discrepancies in the ultrasound lexicon of nodule echotexture and hypoechogenicity. This study aimed to determine the malignancy risk of thyroid nodules according to their echotexture and degree of hypoechogenicity. From June to September 2015, we retrospectively evaluated 5601 thyroid nodules with final diagnoses from 26 institutions. Nodules were stratified according to the echotexture (homogeneous vs. heterogeneous) and degree of hypoechogenicity (mild, moderate, or marked). We calculated the malignancy risk according to composition and suspicious features. Heterogeneous hypoechoic nodules showed a significantly higher malignancy risk than heterogeneous isoechoic nodules (P ≤ 0.017), except in partially cystic nodules. Malignancy risks were not significantly different between homogeneous versus heterogeneous nodules in both hypoechoic (P ≥ 0.086) and iso- hyperechoic nodules (P ≥ 0.05). Heterogeneous iso-hyperechoic nodules without suspicious features showed a low malignancy risk. The malignancy risks of markedly and moderately hypoechoic nodules were not significantly different in all subgroups (P ≥ 0.48). Marked or moderately hypoechoic nodules showed a significantly higher risk than mild hypoechoic (P ≤ 0.016) nodules. The predominant echogenicity effectively stratifies the malignancy risk of nodules with heterogeneous echotexture. The degree of hypoechogenicity could be stratified as mild versus moderate to marked hypoechogenicity.
In cone-beam computed tomography (CBCT), the minimum threshold of the gray value of segmentation is set to convert the CBCT images to the 3D mesh reconstruction model. This study aimed to assess the accuracy of image registration of optical scans to 3D CBCT reconstructions created by different thresholds of grey values of segmentation in partial edentulous jaw conditions. CBCT of a dentate jaw was reconstructed to 3D mesh models using three different thresholds of gray value (−500, 500, and 1500), and three partially edentulous models with different numbers of remaining teeth (4, 8, and 12) were made from each 3D reconstruction model. To merge CBCT and optical scan data, optical scan images were registered to respective 3D reconstruction CBCT images using a point-based best-fit algorithm. The accuracy of image registration was assessed by measuring the positional deviation between the matched 3D images. The Kruskal–Wallis test and a post hoc Mann–Whitney U test with Bonferroni correction were used to compare the results between groups (α = 0.05). The correlations between the experimental factors were calculated using the two-way analysis of variance test. The positional deviations were lowest with the threshold of 500, followed by the threshold of 1500, and then −500. A significant interaction was found between the threshold of gray values and the number of remaining teeth on the registration accuracy. The most significant deviation was observed in the arch model with four teeth reconstructed with a gray-value threshold of −500. The threshold for the gray value of CBCT segmentation affects the accuracy of image registration of optical scans to the 3D reconstruction model of CBCT. The appropriate gray value that can visualize the anatomical structure should be set, especially when few teeth remain in the dental arch.
1 January 2023 in Journal of the Korean Society of Radiology
Purpose: This study evaluated the characteristics of a thyroid-dedicated bipolar RF electrode (BRFE) and compared its ablation performance with that of monopolar RF electrodes (MRFEs) in normal bovine liver blocks. Methods: BRFE was tested on 60 bovine liver blocks with six different time–power combinations, applying 20, 30 and 40 W for 60 and 120 s. Subsequently, BRFE and MRFEs with 0.5-, 0.7- and 1-cm active tips were applied on 160 bovine liver blocks, creating 16 time–electrode combinations (10, 30, 60 and 120 s). The ablation characteristics, RF efficacy and true RF efficacy of each electrode group were then evaluated and compared. True RF efficacy was defined as the total ablation volume created within the total time during which valid RF current was generated. Results: The true RF efficacy of BRFE with 30 W at 60 s was significantly higher than that of BRFE with 20 W and 40 W during the preliminary experiment (p = 0.011). BRFE showed larger vertical and transverse diameters (DT1, DT2) than MRFE with a 0.5-cm active tip (all p values < 0.001, except 10 s). By contrast, MRFE with a 0.7-cm active tip created a larger DT1, DT2, volume, efficacy and true efficacy than BRFE (maximum p value = 0.011). The shape ratio of BRFE was significantly higher than that of MRFEs with 0.5-cm and 0.7-cm tips (all p < 0.001). Conclusions: Application of BRFE with 30 W could achieve a median ablation volumes and efficacy between that of MRFEs with 0.5-cm and 0.7-cm active tips and created a more ellipsoid-shaped ablation zone.