Corrugated steel plate shear wall (CoSPSW) is a lateral load–resisting system in which corrugated infill steel wall panels are embedded inside a steel boundary frame. Compared to flat steel plate shear walls (SPSWs), elastic buckling capacity and lateral stiffness could be enhanced considerably, and gravity loads could be avoided when the load is perpendicular to the rib, or resisted when the load is parallel to the rib, which solves the long-lasting problem of flat wall buckling under gravity loads during construction. Cyclic quasi-static tests were conducted on three, 1/3-scale, 2-story, single-bay CoSPSW specimens with different corrugation orientation and configuration. All specimens showed highly ductile behavior and stable cyclic postbuckling performance. Compared to the SPSW specimen, CoSPSW specimens had much higher lateral stiffness and elastic buckling capacity, with less pinching in the hysteric curves. Different from the tension field action mechanism in SPSW, the lateral load–resisting mechanism in CoSPSWs was shear yielding, or inelastic shear buckling, depending on the corrugation configuration. The experimental results and their implication on seismic design are summarized and discussed.
25 February 2022 in Construction and Building Materials
Experiments and finite element (FE) simulations were conducted on corrugated double-skin composite (Co-DSC) walls consisting of concrete-filled steel tubes (CFTs) and corrugated steel faceplates connected by tie bolts with concrete infill. Three specimens with different aspect ratios and one additional specimen with reinforcing sheaths at the bottom of CFTs were tested under combined axial and cyclic lateral loads. The specimens experienced a similar damage progress involving steel tubes and faceplates buckling and subsequent steel tube fracture. Both the steel tubes and faceplates experienced significant shear; however, the bending moment was predominately resisted by the CFTs. While the slender walls yielded due to flexure, the squat wall yielded due to both flexure resisted by the steel tubes and shear by the corrugated faceplates. All specimens experienced significant shear deformation and achieved a drift ratio capacity exceeding 1.9% and a ductility ratio greater than 3.2. FE models were developed and validated using the test data. The effects of major parameters, including aspect ratio, axial load ratio, and CFT bottom reinforcing method, were examined using the validated models. The numerical simulations indicated slender Co-DSC walls were more sensitive to the axial load ratio. Moreover, using sufficiently thick reinforcing sheaths at the CFT bottom could effectively delay strength degradation. Equations for calculating the lateral strength of Co-DSC were provided.
Studies on the seismic response of skewed integral abutment bridges have mainly focused on response under far-field non-pulse-type ground motions, yet the large amplitude and long-period velocity pulses in near-fault ground motions might have significant impacts on bridge seismic response. In this study, the nonlinear dynamic response of an skewed integral abutment bridge (SIAB) under near-fault pulse and far-fault non-pulse type ground motions are analyzed considering the soil–structure interaction, along with parametric studies on bridge skew angle and compactness of abutment backfill. For the analyses, three sets of near-fault pulse ground motion records are selected based on the bridge site conditions, and three corresponding far-field non-pulse artificial records are fitted by their acceleration response spectra. The results show that the near-fault pulse type ground motions are generally more destructive than the non-pulse motions on the nonlinear dynamic response of SIABs, but the presence of abutment backfill will mitigate the pulse effects to some extent. Coupling of the longitudinal and transverse displacements as well as rotation of the bridge deck would increase with the skew angle, and so do the internal forces of steel H piles. The influence of the skew angle would be most obvious when the abutment backfill is densely compacted.