Ying Tian

Dr. Ying Tian

Department of Civil and Environmental Engineering and Construction, University of Nevada, Las Vegas, NV 89154, USA

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2012 in Construction and Building Materials
Verified
Journal Article
Closed access
ASA.M. Said
A.M. Said
MZM.S. Zeidan
M.S. Zeidan
MBM.T. Bassuoni
M.T. Bassuoni
Ying TianYing Tian
Ying Tian

1 May 2018 in Engineering Structures
Verified
Journal Article
Closed access
LWLiwei Wu
Liwei Wu
Ying TianYing Tian
Ying Tian
YSYoupo Su
Youpo Su
HCHaibin Chen
Haibin Chen

1 September 2017 in Journal of Structural Engineering
Verified
Journal Article
Closed access
ZPZhonghua Peng
Zhonghua Peng
Sarah OrtonSarah Orton
Sarah Orton
JLJinrong Liu
Jinrong Liu
Ying TianYing Tian
Ying Tian
This paper documents the findings from a dynamic collapse experiment carried out on a single-story two-by-two bay reinforced concrete flat-plate substructure. The test specimen had a 0.4 scale, represented older flat-plate buildings designed without structural integrity reinforcement in slabs, and was subjected to an instantaneous removal of an exterior supporting column. Tests were conducted three times with different levels of gravity load until a progressive collapse occurred. The specimen survived a gravity load corresponding to 42% of the normal loading capacity defined by the direct design methods but collapsed at a load of 49% of the design loading capacity. The collapse of the specimen was initiated by the punching failure at an interior slab-column connection carrying the most redistributed load after the exterior column removal. The tests confirmed the existence of slab compressive membrane action and examined the strain rates of material under dynamic response. The tests also indicated that a slab-column connection without continuous slab bottom reinforcement through the column has limited post-punching resistance. The experiment indicated that an older flat-plate building is vulnerable to a progressive collapse when it is subjected to a sudden exterior column removal. Numerical simulations of the experiments using a macromodel were conducted and its effectiveness was confirmed.

1 July 2018 in Journal of Structural Engineering
Verified
Journal Article
Closed access
HXHuizhong Xue
Huizhong Xue
BGBenoit Gilbert
Benoit Gilbert
HGHong Guan
Hong Guan
XLXinzheng Lu
Xinzheng Lu
YLYi Li
Yi Li
Ying TianYing Tian
Ying Tian
Reinforced concrete (RC) flat-plate structures are vulnerable to punching shear failure at their slab-column connections, potentially leading to a catastrophic progressive collapse. In practice, the slab-column connection above an interior column, removed due to abnormal loads, may be subjected to a concentrated downward force because of the absence of the supporting column and further being pushed as a result of different live load intensities on individual stories. This force is different from the full design load that the column withstands in normal situations and, combined with the gravity load acting on the slab, may cause punching shear failure at the interior slab-column connection. This will further trigger failure propagation to the surrounding slab-column connections. This paper presents the experimental tests performed on two identical large-scale 2×2 -bay RC flat-plate specimens under an interior column removal scenario. A 5-kPa uniformly distributed load was applied first to the slab followed by an incremental concentrated force imposed on the slab-column connection above the removed interior column. The complete collapse-resistant behavior and load redistribution pattern of the specimens were investigated and are reported herein. Results show that more than 90% of the applied concentrated force is solely distributed to the four nearest adjacent columns. Three load-carrying mechanism phases, in the form of flexural, tensile membrane, and a combination of one-way catenary and dowel actions can be distinguished in resisting the applied concentrated load.

30 June 2011 in International Journal of Concrete Structures and Materials
Verified
Journal Article
Closed access
Ying TianYing Tian
Ying Tian
YSYoupo Su
Youpo Su

1 October 2020 in Engineering Structures
Verified
Journal Article
Closed access
QZQiuhong Zhao
Qiuhong Zhao
YLYikang Li
Yikang Li
Ying TianYing Tian
Ying Tian