This article presents the concept of boundary-based predictive controller (BBPC) as an effective tool to control industrial processes with on- - off actuator, for which the control goal is defined to keep the process output within the desired range. An example use of BBPC is shown in application to control of dissolved oxygen (DO) concentration in the laboratory activated sludge setup with biological reactor. It is suggested how to identify dynamical parameters of the proposed DO concentration model and how to provide adaptability required to ensure desired control performance in the presence of significant changes of process load disturbance. Practical implementation in programmable logic controller in the form of a general purpose library function block is also presented. Experimental comparison with conventional on – off controller shows robustness and superiority of the proposed BBPC.
21 May 2014 in Transactions of the Institute of Measurement and Control
This paper deals with the practical aspects of the implementation of the balance-based adaptive control (B-BAC) technique. It gives the simple mathematical background of this methodology, shows the case-independent implementation concept as the ready-to-use flexible function block that results from the B-BAC generality, discusses how to embed the additional functionalities required in professional industrial control applications and finally presents three implementation examples for three different programming and hardware platforms. The control performance of each B-BAC function block is validated experimentally and compared with the performance of the corresponding platform-related standard PID function blocks. The comparative results and the potential accessibility of both the flexible function block and the simple tuning method put forward B-BAC methodology as a strong alternative for PID-based industrial control applications.
This paper presents the intuitive and ready-to-use, general procedure for tuning the balance-based adaptive controller (B-BAC) based on its equivalence to the controller with PI term and with additional improvements shown for the linearised approximation of the dynamics of the nonlinear controlled process. The simple formulas are suggested to calculate the B-BAC tunings based on the PI tunings determined by any PI tuning procedure chosen accordingly to the desired closed-loop performance. This methodology is verified by comparing the closed-loop performance of the equivalently tuned B-BAC and PI/PI+feedforward controllers under the same scenario, both by the simulation and practical experiments.
Safety and reliability of constructions operated are predicted using the known mechanical properties of materials and geometry of cross-sections, and also the known internal forces. The extensometry technique (electro-resistant tensometers, wire gauges, sensor systems) is a common method applied under laboratory conditions to determine the deformation state of a material. The construction sector rarely uses ultrasonic extensometry with the acoustoelastic (AE) method which is based on the relation between the direction of ultrasonic waves and the direction of normal stresses. It is generally used to identify stress states of machine or vehicles parts, mainly made of steel, characterized by high homogeneity and a lack of inherent internal defects. The AE effect was detected in autoclaved aerated concrete (AAC), which is usually used in masonry units. The acoustoelastic effect was used in the tests described to identify the complex stress state in masonry walls (masonry units) made of AAC. At first, the relationships were determined for mean hydrostatic stresses P and mean compressive stresses σ3 with relation to velocities of the longitudinal ultrasonic wave cp. These stresses were used to determine stresses σ3. The discrete approach was used which consists in analyzing single masonry units. Changes in velocity of longitudinal waves were identified at a test stand to control the stress states of an element tested by the digital image correlation (DIC) technique. The analyses involved density and the impact of moisture content of AAC. Then, the method was verified on nine walls subjected to axial compression and the model was validated with the FEM micromodel. It was demonstrated that mean compressive stresses σ3 and hydrostatic stresses, which were determined for the masonry using the method considered, could be determined even up to ca. 75% of failure stresses at the acceptable error level of 15%. Stresses σ1 parallel to bed joints were calculated using the known mean hydrostatic stresses and mean compressive stresses σ3.