manila caragiuli

Dr. manila caragiuli


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Journal of Biomechanics
Verified
Journal Article
Closed access
MCmanila caragiuli
manila caragiuli
Marco MandoliniMarco Mandolini
Marco Mandolini
Daniele LandiDaniele Landi
Daniele Landi
Giovanni BrunoGiovanni Bruno
Giovanni Bruno
Alberto De StefaniAlberto De Stefani
Alberto De Stefani
ITIlaria Toniolo
Ilaria Toniolo

3 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Giovanni BrunoGiovanni Bruno
Giovanni Bruno
Alberto De StefaniAlberto De Stefani
Alberto De Stefani
MCmanila caragiuli
manila caragiuli
FZFrancesca Zalunardo
Francesca Zalunardo
Alida MazzoliAlida Mazzoli
Alida Mazzoli
Antonio GraccoAntonio Gracco
Antonio Gracco
AIM: The purpose of this study is to compare the stress effects developed on the periodontal ligaments and teeth by three different types of mandibular advancement devices (MADs) using a finite element method (FEM) analysis. Introduction: Obstructive sleep apnea (OSA) is a disease with a high prevalence and, in recent years, the use of MADs as an alternative or support treatment to the continuous positive airway pressure (CPAP) has spread. Their use finds relative contraindications in the case of partial edentulism and severe periodontal disease. Given the widespread of periodontal problems, it is essential to know the effects that these devices cause on the periodontal ligament of the teeth. Materials and methods: Starting from the computed tomography (CT) scan of a patient’s skull, 3D reconstructions of the maxilla and mandible were implemented. Three different MADs were prepared for the patient, then 3D scanned, and lastly, coupled with the 3D models of the jaws. The devices have two different mechanics: One has a front reverse connecting rod (OrthoapneaTM), and two have lateral propulsion (SomnodentTM and HerbstTM). A FEM analysis was performed to calculate the stress applied on periodontal ligaments, on every single tooth and the displacement vectors that are generated by applying an advancement force on the mandible. Results: HerbstTM and SomnodentTM devices present very similar stress values, mainly concentrated on lateral teeth, but in general, the forces are very mild and distributed. The maximum stresses values are 3.27 kPa on periodontal ligaments and 287 kPa on teeth for SomnodentTM and 3.56 kPa on periodontal ligaments and 302 kPa on teeth for HerbstTM. OrthoapneaTM has, instead, higher and concentrated stress values, especially in the anterior maxillary and mandibular area with 4.26 kPa and 600 kPa as maximum stress values, respectively, on periodontal ligaments and teeth. Conclusions: From the results, it is concluded that devices with a bilateral mechanism generate less and more distributed stress than an anterior connecting rod mechanism. Therefore, they may be advisable to patients with compromised periodontal conditions in the anterior area.

13 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
Giovanni BrunoGiovanni Bruno
Giovanni Bruno
Alberto De StefaniAlberto De Stefani
Alberto De Stefani
ECEdoardo Conte
Edoardo Conte
MCmanila caragiuli
manila caragiuli
Marco MandoliniMarco Mandolini
Marco Mandolini
Antonio GraccoAntonio Gracco
Antonio Gracco
Background: Sleep-Related Breathing Disorders are characterized by repeated episodes of complete or partial obstruction of the upper airway during sleep. Mandibular advancement devices represent a non-invasive treatment in reducing the number of respiratory events and in decreasing symptoms. The advancement extent of these devices is responsible for the mandibular roto-translation and its effects on the temporomandibular joint. Methods: This study defined a systematic method to assess the mandible roto translation that is caused by MADs according to a scan-to-CAD approach. Starting from a closed mouth position and simulating the oral appliance at different settings it was possible to define a local reference system that is useful for the evaluation of the mandibular roto-translation. This latter was then applied to evaluate the movements of the condyle and the mandibular dental arch. Results: MAD1 resulted in a reduced mouth opening and protrusion, while MAD2 enabled a higher degree of motion of the mandible useful for patients who need an important protrusion. Conclusions: The two devices present different dynamics. Results that are achievable employing this method can be directly used by practitioners in comparing MADs, as well as by researchers in evaluating MADs effects.

7 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ABAgnese Brunzini
Agnese Brunzini
MCmanila caragiuli
manila caragiuli
CMChiara Massera
Chiara Massera
Marco MandoliniMarco Mandolini
Marco Mandolini
In response to rapid population ageing, digital technology represents the greatest resource in supporting the implementation of active and healthy ageing principles at clinical and service levels. However, digital information platforms that deliver coordinated health and social care services for older people to cover their needs comprehensively and adequately are still not widespread. The present work is part of a project that focuses on creating a new personalised healthcare and social assistance model to enhance older people’s quality of life. This model aims to prevent acute events to favour the elderly staying healthy in their own home while reducing hospitalisations. In this context, the prompt identification of criticalities and vulnerabilities through ICT devices and services is crucial. According to the human-centred care vision, this paper proposes a decision-support algorithm for the automatic and patient-specific assignment of tailored sets of devices and local services based on adults’ health and social needs. This decision-support tool, which uses a tree-like model, contains conditional control statements. Using sequences of binary divisions drives the assignation of products and services to each user. Based on many predictive factors of frailty, the algorithm aims to be efficient and time-effective. This goal is achieved by adequately combining specific features, thresholds, and constraints related to the ICT devices and patients’ characteristics. The validation was carried out on 50 participants. To test the algorithm, its output was compared to clinicians’ decisions during the multidimensional evaluation. The algorithm reported a high sensitivity (96% for fall monitoring and 93% for cardiac tracking) and a lower specificity (60% for fall monitoring and 27% for cardiac monitoring). Results highlight the preventive and protective behaviour of the algorithm.

5 July 2023
Verified
Conference Paper
Open access
ABAgnese Brunzini
Agnese Brunzini
MCmanila caragiuli
manila caragiuli
FAFlavia Atzori
Flavia Atzori
MBMicol Bronzini
Micol Bronzini
MGMichele Germani
Michele Germani
The population aging phenomenon has been increasing in the last years and will become prevailing in the future ones. In the era of Healthcare 4.0, the application of information and communication technologies (ICT) is the main enabler for the health and social care sectors, advancing user-centered care and preventing or delaying frailty conditions. This work focuses on a preliminary usability and user experience (UX) assessment regarding a self-monitoring device, smartphone, and tablet, with a 5-users sample. The user interface layout and content of smartphone and tablet have been previously simplified according to the human-computer interaction principles, to hinder the digital divide inherent to the Silver Generation. Structured and semi-structured interviews have been conducted to evaluate users’ expectations, familiarity, and acceptance of ICT devices. A specific assessment protocol has been designed to evaluate the usability of devices. Preliminary results show that all participants were able to complete the test with few committed errors. However, even if a good inclination toward the use of smart technologies emerged, the need for digital mediation and individual training sessions is undisputed.

5 June 2024 in International Dental Journal
Verified
Journal Article
Open access
MCmanila caragiuli
manila caragiuli
MCMara Candelari
Mara Candelari
FZFrancesca Zalunardo
Francesca Zalunardo
GBGiovanni Bruno
Giovanni Bruno
ASAlberto De Stefani
Alberto De Stefani
Marco MandoliniMarco Mandolini
Marco Mandolini
In the literature, no studies correlate the effects of mandibular advancement devices (MADs) with different titration systems to periodontitis. Through a finite element analysis (FEA), this study investigates the effects generated on periodontal ligaments (PDLs) and teeth by four commercial MADs in periodontal health and with 15% bone resorption. Four MADs (Somnodent Flex™, Somnodent Avant™, Orthoapnea™, and Herbst™) were digitalised starting from the impressions of a patient's dental arches. A force of 11.18 N, representing an advancement of 9.5 mm, was applied, and a FEA was subsequently performed. After measuring the stresses and displacements on the PDLs and teeth in healthy periodontal conditions, the vertical dimension of the alveolar bone was reduced by 15%, and measurements were repeated. In terms of PDL stress, Herbst™ is the device which guarantees a more uniform increment in case of the first stage of periodontitis (+7% for mandibular and maxillary PDLs compared to the healthy condition). For Somnodent™ devices, the PDLs stress increment is almost null for mandibular PDLs but much higher than Herbst™ for maxillary PDLs (+17% and +21% for Flex™ and Avant™). Orthoapnea™ determines a PDL stress augmentation between the other devices (+16% and +7%, respectively, for maxillary and mandibular PDLs). Concerning teeth movement, Herbst™ and Orthoapnea™ determine a lower and more uniform displacement than Somnodent devices. The stress distribution and teeth displacement are strictly related to MAD geometry. Since its minor effects on teeth and PDLs, the Herbst™ could be more appropriate in patients with periodontitis.