In this paper, the behavior of a doubly fed induction generator (DFIG) is studied under unbalanced grid voltage conditions. It is shown that if no special control efforts are employed, the behavior of the generator is deteriorated, basically due to two reasons: electromagnetic torque oscillations and nonsinusoidal current exchange with the grid. These phenomena are first analyzed theoretically as a function of the stator active and reactive instantaneous power exchange by the stator of the DFIG and the grid-side converter (GSC). This analysis provides the main ideas for generation of the active and reactive power references for the rotor-side converter (RSC) and the GSC, controlled by means of direct power control techniques. Therefore, this paper proposes a new algorithm that generates the RSC power references, without the necessity of a sequence component extraction, in order to eliminate torque oscillations and achieve sinusoidal stator currents exchange. On the contrary, the GSC power references are provided by means of voltage and current sequence extraction. Finally, simulation and experimental results successfully validate the proposed power reference generation methods.
22 February 2008 in IEEE Transactions on Industrial Electronics
The power generation system with a doubly fed induction generator (DFIG), which can be used as an autonomous power system after the loss of mains in a distributed generation network, is described. After the mains outage, a fixed frequency and an amplitude of the output voltage are obtained, despite the variable rotor speed. For this reason, it can be successfully applied in the variable-speed wind turbines, adjustable speed water plants, or diesel engines. Moreover, the stand-alone operation of DFIG is useful in a flywheel-based high-energy rotary uninterruptible power supply system. An output voltage is controlled directly by the synchronization of an actual voltage vector with the reference vector represented in a synchronously rotating polar frame. The rotor current angular speed is obtained as a result of vectorial phase-locked loop operation. Any sensors or estimators of the rotor speed or position are unnecessary. Both amplitude and angle control loops are linear. The use of stand-alone operation in grid-connected systems requires mains outage detection. Also, the grid voltage recovery requires a method of synchronization and soft connection of a generator to the grid. The proposed methods of output voltage control, synchronization, and detection of mains loss were tested in a laboratory system.
2 April 2007 in IEEE Transactions on Industrial Electronics
In this letter, a stand-alone power system with doubly fed induction generator is described. Direct voltage control based on the stator voltage vector, represented in rotating polar frame, does not need any feedback from the rotor speed or position. Using positive- and negative-sequence components, an unbalanced load can be supplied
3 December 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Accurate rotor time constant (Tr) value is necessary to ensure an acceptable performance of the indirect field oriented control (IFOC) strategy, where a detuned Tr affects rotor flux orientation, in turn, results in poor dynamic and steady-state response of torque. The problems associated with detuned Tr will be exacerbated in sensorless drives, when a model-based speed estimation algorithm is employed. This paper investigates the problem of simultaneous identification of the rotor time constant and rotor speed for sensorless IFOC of six-phase induction motor (6PIM) drives. First, an adaptive observer is proposed for online detection of the low-frequency sinusoidal signal, which is intentionally injected to the rotor flux command. Then, a novel model reference adaptive system (MRAS)-based Tr estimator is proposed using the detected signal. The Lyapunov stability theorem is used to ensure the asymptotic stability of the proposed identification system. The proposed method is based on the induction machine model in primary subspace, i.e., α-β subspace. Hence, it is usable for other multi-phase induction machine (three-phase and higher). Nevertheless, the 6PIM is adopted here as a case study. The simulation and experimental results clarify the effectiveness of the proposed parallel estimation system.
The paper presents a decoupled direct power-controlled (DPC) of a doubly fed induction generator (DFIG) connected to an unbalanced power grid, executed in an orthogonal stationary reference frame related to the stator side. The control allows to maintain constant electromagnetic torque despite stator connection to the unbalanced power grid and to achieve controllable low-voltage ride through (LVRT) capability. The control does not require any signal decomposition into positive and negative sequence order, which allows to reduce its complexity and computational requirements. Then, the paper presents positive influence of rotor current feedback in the stator-controlled reference frame on control performance. It facilitates significant transient reduction and minor steady state control improvement. All the mentioned functionalities were validated both in simulation and in laboratory conditions and the obtained results are described in the paper.