Soonjae Ahn

Prof. Dr. Soonjae Ahn

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SASoonjae Ahn
Soonjae Ahn
JKJongman Kim
Jongman Kim
BKBummo Koo
Bummo Koo
YKYoungho Kim
Youngho Kim
In this study, pre-impact fall detection algorithms were developed based on data gathered by a custom-made inertial measurement unit (IMU). Four types of simulated falls were performed by 40 healthy subjects (age: 23.4 ± 4.4 years). The IMU recorded acceleration and angular velocity during all activities. Acceleration, angular velocity, and trunk inclination thresholds were set to 0.9 g, 47.3°/s, and 24.7°, respectively, for a pre-impact fall detection algorithm using vertical angles (VA algorithm); and 0.9 g, 47.3°/s, and 0.19, respectively, for an algorithm using the triangle feature (TF algorithm). The algorithms were validated by the results of a blind test using four types of simulated falls and six types of activities of daily living (ADL). VA and TF algorithms resulted in lead times of 401 ± 46.9 ms and 427 ± 45.9 ms, respectively. Both algorithms were able to detect falls with 100% accuracy. The performance of the algorithms was evaluated using a public dataset. Both algorithms detected every fall in the SisFall dataset with 100% sensitivity). The VA algorithm had a specificity of 78.3%, and TF algorithm had a specificity of 83.9%. The algorithms had higher specificity when interpreting data from elderly subjects. This study showed that algorithms using angles could more accurately detect falls. Public datasets are needed to improve the accuracy of the algorithms.

31 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YKYoungho Kim
Youngho Kim
IHIncheol Han
Incheol Han
JJJeyong Jung
Jeyong Jung
SYSumin Yang
Sumin Yang
SLSeung Hee Lee
Seung Hee Lee
SSSung-Hyuk Song
Sung-Hyuk Song
The quantification of comfort in binding parts, essential human–machine interfaces (HMI) for the functioning of rehabilitation robots, is necessary to reduce physical strain on the user despite great achievements in their structure and control. This study aims to investigate the physiological impacts of binding parts by measuring electrodermal activity (EDA) and tissue oxygen saturation (StO2). In Experiment 1, EDA was measured from 13 healthy subjects under three different pressure conditions (10, 20, and 30 kPa) for 1 min using a pneumatic cuff on the right thigh. In Experiment 2, EDA and StO2 were measured from 10 healthy subjects for 5 min. To analyze the correlation between EDA parameters and the decrease in StO2, a survey using the visual analog scale (VAS) was conducted to assess the level of discomfort at each pressure. The EDA signal was decomposed into phasic and tonic components, and the EDA parameters were extracted from these two components. RM ANOVA and a post hoc paired t-test were used to determine significant differences in parameters as the pressure increased. The results showed that EDA parameters and the decrease in StO2 significantly increased with the pressure increase. Among the extracted parameters, the decrease in StO2 and the mean SCL proved to be effective indicators. Such analysis outcomes would be highly beneficial for studies focusing on the comfort assessment of the binding parts of rehabilitation robots.

23 August 2023
Verified
Book Chapter
Open access
PDF file
SASoonjae Ahn
Soonjae Ahn
IMInhyuk Moon
Inhyuk Moon
Recently, care robots are being developed that incorporate robotics into assistive products that focus on daily care for the physically disabled or elderly with reduced physical function. However, although care robots can reduce the physical burden of human intervention, they can also be dangerous depending on their situational awareness. This study describes a standardization that defines safety requirements for care robots and includes verification methods to test their safety requirements. As an example of the application of this standard, a standard for the safety and performance method of a feeding robot is shown. This standardization study is expected to contribute to the spread of care robots in the future.

22 September 2023
Verified
Book Chapter
Open access
PDF file
SASoonjae Ahn
Soonjae Ahn
SYSunwoo Yuk
Sunwoo Yuk
WYWoojin Yu
Woojin Yu
IMInhyuk Moon
Inhyuk Moon
Recently, care robots are being developed that incorporate robotics into assistive products that focus on daily care for the physically disabled or elderly with reduced physical function. However, although care robots can reduce the physical burden of human intervention, they can also be dangerous depending on their situational awareness. This study describes a standardization that defines safety requirements for care robots and includes an evaluation method to test their safety based on these requirements. As an example of the application of this standard, a standard for the safety and performance method of a meal assistant robot is shown. This standardization study is expected to contribute to the spread of care robots in the future.