Sumin Yang

Sumin Yang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SLSeung Hee Lee
Seung Hee Lee
BKBummo Koo
Bummo Koo
SYSumin Yang
Sumin Yang
JKJongman Kim
Jongman Kim
YNYejin Nam
Yejin Nam
YKYoungho Kim
Youngho Kim
Workers at construction sites are prone to fall-from-height (FFH) accidents. The severity of injury can be represented by the acceleration peak value. In the study, a risk prediction against FFH was made using IMU sensor data for accident prevention at construction sites. Fifteen general working movements (NF: non-fall), five low-hazard-fall movements, (LF), and five high-hazard-FFH movements (HF) were performed by twenty male subjects and a dummy. An IMU sensor was attached to the T7 position of the subject to measure the three-axis acceleration and angular velocity. The peak acceleration value, calculated from the IMU data, was 4 g or less in general work movements and 9 g or more in FFHs. Regression analysis was performed by applying various deep learning models, including 1D-CNN, 2D-CNN, LSTM, and Conv-LSTM, to the risk prediction, and then comparing them in terms of their mean absolute error (MAE) and mean squared error (MSE). The FFH risk level was estimated based on the predicted peak acceleration. The Conv-LSTM model trained by MAE showed the smallest error (MAE: 1.36 g), and the classification with the predicted peak acceleration showed the best accuracy (97.6%). This study successfully predicted the FFH risk levels and could be helpful to reduce fatal injuries at construction sites.

14 October 2023 in Sensors
Verified
Journal Article
Open access
PDF file
BKBummo Koo
Bummo Koo
XYXiaoqun Yu
Xiaoqun Yu
SLSeung Hee Lee
Seung Hee Lee
SYSumin Yang
Sumin Yang
DKDongkwon Kim
Dongkwon Kim
YKYoungho Kim
Youngho Kim
Falls represent a significant health concern for the elderly. While studies on deep learning-based preimpact fall detection have been conducted to mitigate fall-related injuries, additional efforts are needed for embedding in microcomputer units (MCUs). In this study, ConvLSTM, the state-of-the-art model, was benchmarked, and we attempted to lightweight it by leveraging features from image-classification models VGGNet and ResNet while maintaining performance for wearable airbags. The models were developed and evaluated using data from young subjects in the KFall public dataset based on an inertial measurement unit (IMU), leading to the proposal of TinyFallNet based on ResNet. Despite exhibiting higher accuracy (97.37% < 98.00%) than the benchmarked ConvLSTM, the proposed model requires lower memory (1.58 MB > 0.70 MB). Additionally, data on the elderly from the fall data of the FARSEEING dataset and activities of daily living (ADLs) data of the KFall dataset were analyzed for algorithm validation. This study demonstrated the applicability of image-classification models to preimpact fall detection using IMU and showed that additional tuning for lightweighting is possible due to the different data types. This research is expected to contribute to the lightweighting of deep learning models based on IMU and the development of applications based on IMU data.

19 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JKJongman Kim
Jongman Kim
SYSumin Yang
Sumin Yang
BKBummo Koo
Bummo Koo
SLSeunghee Lee
Seunghee Lee
SPSeHoon Park
SeHoon Park
YKYoungho Kim
Youngho Kim
SEMG-based gesture recognition is useful for human–computer interactions, especially for technology supporting rehabilitation training and the control of electric prostheses. However, high variability in the sEMG signals of untrained users degrades the performance of gesture recognition algorithms. In this study, the hand posture recognition algorithm and radar plot-based visual feedback training were developed using multichannel sEMG sensors. Ten healthy adults and one bilateral forearm amputee participated by repeating twelve hand postures ten times. The visual feedback training was performed for two days and five days in healthy adults and a forearm amputee, respectively. Artificial neural network classifiers were trained with two types of feature vectors: a single feature vector and a combination of feature vectors. The classification accuracy of the forearm amputee increased significantly after three days of hand posture training. These results indicate that the visual feedback training efficiently improved the performance of sEMG-based hand posture recognition by reducing variability in the sEMG signal. Furthermore, a bilateral forearm amputee was able to participate in the rehabilitation training by using a radar plot, and the radar plot-based visual feedback training would help the amputees to control various electric prostheses.

1 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
SYSumin Yang
Sumin Yang
BKBummo Koo
Bummo Koo
SLSeung Hee Lee
Seung Hee Lee
DJDaejin Jang
Daejin Jang
HSHyunjun Shin
Hyunjun Shin
YKYoungho Kim
Youngho Kim
Gait event detection is essential for controlling an orthosis and assessing the patient’s gait. In this study, patients wearing an electromechanical (EM) knee–ankle–foot orthosis (KAFO) with a single IMU embedded in the thigh were subjected to gait event detection. The algorithm detected four essential gait events (initial contact (IC), toe off (TO), opposite initial contact (OIC), and opposite toe off (OTO)) and determined important temporal gait parameters such as stance/swing time, symmetry, and single/double limb support. These gait events were evaluated through gait experiments using four force plates on healthy adults and a hemiplegic patient who wore a one-way clutch KAFO and a pneumatic cylinder KAFO. Results showed that the smallest error in gait event detection was found at IC, and the largest error rate was observed at opposite toe off (OTO) with an error rate of −2.8 ± 1.5% in the patient group. Errors in OTO detection resulted in the largest error in determining the single limb support of the patient with an error of 5.0 ± 1.5%. The present study would be beneficial for the real-time continuous monitoring of gait events and temporal gait parameters for persons with an EM KAFO.

16 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YNYejin Nam
Yejin Nam
SYSumin Yang
Sumin Yang
JKJongman Kim
Jongman Kim
BKBummo Koo
Bummo Koo
SSSung-Hyuk Song
Sung-Hyuk Song
YKYoungho Kim
Youngho Kim
Human-machine interfaces (HMI) refer to the physical interaction between a user and rehabilitation robots. A persisting excessive load leads to soft tissue damage, such as pressure ulcers. Therefore, it is necessary to define a comfortable binding part for a rehabilitation robot with the subject in a standing posture. The purpose of this study was to quantify the comfort at the binding parts of the standing rehabilitation robot. In Experiment 1, cuff pressures of 10–40 kPa were applied to the thigh, shank, and knee of standing subjects, and the interface pressure and pain scale were obtained. In Experiment 2, cuff pressures of 10–20 kPa were applied to the thigh, and the tissue oxygen saturation and the skin temperature were measured. Questionnaire responses regarding comfort during compression were obtained from the subjects using the visual analog scale and the Likert scale. The greatest pain was perceived in the thigh. The musculoskeletal configuration affected the pressure distribution. The interface pressure distribution by the binding part showed higher pressure at the intermuscular septum. Tissue oxygen saturation (StO2) increased to 111.9 ± 6.7% when a cuff pressure of 10 kPa was applied and decreased to 92.2 ± 16.9% for a cuff pressure of 20 kPa. A skin temperature variation greater than 0.2 °C occurred in the compressed leg. These findings would help evaluate and improve the comfort of rehabilitation robots.

31 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YKYoungho Kim
Youngho Kim
IHIncheol Han
Incheol Han
JJJeyong Jung
Jeyong Jung
SYSumin Yang
Sumin Yang
SLSeung Hee Lee
Seung Hee Lee
SSSung-Hyuk Song
Sung-Hyuk Song
The quantification of comfort in binding parts, essential human–machine interfaces (HMI) for the functioning of rehabilitation robots, is necessary to reduce physical strain on the user despite great achievements in their structure and control. This study aims to investigate the physiological impacts of binding parts by measuring electrodermal activity (EDA) and tissue oxygen saturation (StO2). In Experiment 1, EDA was measured from 13 healthy subjects under three different pressure conditions (10, 20, and 30 kPa) for 1 min using a pneumatic cuff on the right thigh. In Experiment 2, EDA and StO2 were measured from 10 healthy subjects for 5 min. To analyze the correlation between EDA parameters and the decrease in StO2, a survey using the visual analog scale (VAS) was conducted to assess the level of discomfort at each pressure. The EDA signal was decomposed into phasic and tonic components, and the EDA parameters were extracted from these two components. RM ANOVA and a post hoc paired t-test were used to determine significant differences in parameters as the pressure increased. The results showed that EDA parameters and the decrease in StO2 significantly increased with the pressure increase. Among the extracted parameters, the decrease in StO2 and the mean SCL proved to be effective indicators. Such analysis outcomes would be highly beneficial for studies focusing on the comfort assessment of the binding parts of rehabilitation robots.