Zbigniew Raszewski

Dr. Zbigniew Raszewski

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Mini-Reviews in Medicinal Chemistry
Verified
Journal Article
Closed access
PDF file
Zbigniew RaszewskiZbigniew Raszewski
Zbigniew Raszewski
ANAgnieszka Nowakowska-Toporowska
Agnieszka Nowakowska-Toporowska
DNDanuta Nowakowska
Danuta Nowakowska
WWWłodzimierz Więckiewicz
Włodzimierz Więckiewicz
Acrylic resins are the most commonly used materials in prosthetics and orthodontics until now. They have a well-documented history of use as biomaterials in the manufacturing of different types of dental appliances. The objective of this study was to describe the properties of acrylic resins and the processing methods used for these materials in dentistry. The review depicts the most important achievements in this area, indicating that the resin technology evolved in different directions. The mechanical and biological properties of acrylic resins were improved by the addition of mineral or natural fibers, and/or fillers, including nanofillers, as well as by poly(methyl methacrylate) surface modification. The presence of residual monomer was reduced as a result of postpolymerization activity. New types of acrylic resins were developed for processing Computer-Aided Design/Computer- Aided Manufacturing systems and three-dimensional printing.

31 December 2020 in Dental and Medical Problems
Verified
Journal Article
Open access
Zbigniew RaszewskiZbigniew Raszewski
Zbigniew Raszewski
At present, new acrylic plastic technologies are being developed in dentistry. Although this kind of material has been used for dental prostheses for over 80 years, it has been produced in the form of disks with the computer-aided design/computer-aided manufacturing (CAD/CAM) technology for over 15 years. The purpose of the article was to collect information from the literature on acrylic materials processed through the milling technology (CAD/CAM). The publicly available databases PubMed, Google Scholar and Scopus were searched using the key word "acrylic resins, CAD/CAM". All articles describing the application and testing of CAD/CAM disks were selected. Duplicate articles were removed. More than 100 articles that described the use of materials machined using the milling equipment were found. These included works comparing the mechanical properties, biocompatibility and clinical use of the materials. After the initial selection, 36 papers on this subject were included in this review. The number of studies on the processing of acrylic materials with the use of the CAD/CAM technology has been increasing worldwide. Since such materials have better mechanical properties, no polymerization shrinkage occurs during processing, the amount of residual monomer material is very low and they have better color stability than self-curing materials.

Verified
Journal Article
Open access
PDF file
Zbigniew RaszewskiZbigniew Raszewski
Zbigniew Raszewski
KCKatarzyna Chojnacka
Katarzyna Chojnacka
MMMarcin Mikulewicz
Marcin Mikulewicz
Background: Color stability is a crucial performance parameter for dental restorations, and limited research exists on how surface preparation methods affect it. The purpose of this study was to test the color stability of three resins intended for 3D printing, which can be used to make dentures or crowns in A2 and A3 colors. Materials and Methods: Samples were prepared in the form of incisors; the first group was not subjected to any treatment after curing and washing with alcohol, the second was covered with light-curing varnish, and the third was polished in a standard way. Then, the samples were placed in solutions of coffee, red wine, and distilled water and stored in the laboratory. After 14, 30, and 60 days, color changes were measured (presented as Delta E) compared to material stored in the dark. Results: The greatest changes were observed for samples that were not polished, then were placed in red wine dilutions (ΔE = 18.19 ± 0.16). Regarding the samples covered with varnish, during storage, some parts detached, and the dyes penetrated inside. Conclusions: 3D-printed material should be polished as thoroughly as possible to limit the adhesion of dyes from food to their surface. Applying varnish may be a temporary solution.

5 October 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Zbigniew RaszewskiZbigniew Raszewski
Zbigniew Raszewski
KCKatarzyna Chojnacka
Katarzyna Chojnacka
MMMarcin Mikulewicz
Marcin Mikulewicz
This study aimed to prepare a bioactive acrylic material by adding different types of glasses. Commercially available polymerized acrylic resin was mixed with 10% of four different types of glasses in the powder form and cured. Flexural strength, sorption, and solubility of the samples were tested according to ISO 20795-1:2013. The total number of samples used in the tests were 60. The materials were placed in artificial saliva of pH 4 and 7, and elution was performed for 0, 1, 28, and 42 days. The collected samples were analyzed using inductively coupled plasma atomic emission spectrometry to detect Ca, P, and Si ions and using ion chromatography to detect F ions. The materials obtained after modification with glasses showed lower compressive strength compared with pure polymethyl methacrylate but met the standard requirements. Two glass types showed higher solubility values compared with the value defined by the ISO standard. Biomin C and S53P4 released Ca, P, and Si ions, respectively, after 42 days in artificial saliva. Acrylic resins modified with 10% Biomin C and S53P4 glasses can be a valuable source of Ca and P ions under acid conditions for 28 and 42 days.

18 March 2019 in Advances in Clinical and Experimental Medicine
Verified
Journal Article
Open access
Zbigniew RaszewskiZbigniew Raszewski
Zbigniew Raszewski
ANAgnieszka Nowakowska-Toporowska
Agnieszka Nowakowska-Toporowska
JWJoanna Wezgowiec
Joanna Wezgowiec
DNDanuta Nowakowska
Danuta Nowakowska
Chlorhexidine-based products are often used in medicine and dentistry as dental hygiene and therapeutic products, especially by patients with various oral tissue diseases. However, these products have disadvantages, such as low stability, as well as discoloration of the teeth and dental reconstruction materials. The aim of this study was to create and evaluate experimental chlorhexidine (CHX) gels with anti-staining properties and to compare them with 3 commercially available products. For this study, 4 new formulations containing 1% CHX and different anti-staining agents were developed. The properties of these gels were compared with 3 commercial CHX-based dental products. The pH, viscosity, disintegration in water, and anti-staining properties were evaluated. The pH level of the 4 new CHX gels ranged from 5.92 to 6.33. The viscosity of the experimental gels was higher (85.7÷217.7 Pa∙s) than the commercial ones (11.6÷72.7 Pa∙s). Among the experimental formulations with 1% CHX, the formulation with 5% polyvinylpyrrolidone (PVP) and 0.2% citric acid and the formulation with 1% citric acid were the most stable in terms of pH and viscosity. The disintegration times of the experimental gels were longer (50-70 min) as compared with the commercial products (approx. 20 min). These 2 CHX gels caused less color change of glass ionomer cements in black tea solution. To conclude, 2 new experimental dental gels based on 1% CHX, one with 1% citric acid and the second with 5% PVP and 0.2% citric acid, had the most favorable physicochemical properties. Further research is needed to evaluate their therapeutic potential in the treatment of diseases of the oral cavity.

Verified
Journal Article
Open access
PDF file
Zbigniew RaszewskiZbigniew Raszewski
Zbigniew Raszewski
KCKatarzyna Chojnacka
Katarzyna Chojnacka
Julita KulbackaJulita Kulbacka
Julita Kulbacka
MMMarcin Mikulewicz
Marcin Mikulewicz
The aim of this study was to create a 3D printing material with bioactive properties that potentially could be used for a transparent removable orthodontic appliance. Materials and methods. To acrylic monomers, four bioactive glasses at 10% concentration were added, which release Ca, P, Si and F ions. The materials were printed on a 3D printer and tested for flexural strength (24 h and 30 days), sorption and solubility (7 days), ion release to artificial saliva pH = 4 and 7 (42 days) and cytotoxicity in the human fibroblast model. The released ions were determined by plasma spectrometry (Ca, P and Si ions) and ion-selective electrode (F measurement)s. Results: The material obtained released Ca2+ and PO43− ions for a period of 42 days when using glass Biomin C at pH 4. The flexural strength depended on the direction in which the sample was printed relative to the 3D printer platform. Vertically printed samples had a resistance greater than 20%. The 10% Biomin C samples post-cured for 30 min with light had a survival rate of the cells after 72 h of 85%.Conclusions. Material for 3D printing with bioactive glass in its composition, which releases ions, can be used in the production of orthodontic aligners.