James Sheets

Dr. James Sheets

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2020 in Prosthesis
Verified
Journal Article
Open access
PDF file
JSJames Sheets
James Sheets
AWAlvin G. Wee
Alvin G. Wee
BSBobby Simetich
Bobby Simetich
Mark BeattyMark Beatty
Mark Beatty
The objective of this study was to assess if the setting expansion, compressive strength, compressive modulus and Knoop hardness is reduced in Type III, IV and V gypsum products when excess water is added to recommended water/powder (W/P) ratios for full-arch implant master casts. Four properties were measured: linear setting expansion, compressive strength, compressive modulus, and Knoop hardness. Three dental stones were evaluated: ISO Type III, Type IV, and Type V. Water was added to recommended W/P ratios as follows: (1) 0%, the manufacturer’s recommend W/P ratio, (2) 50%, 1.5 times the manufacturer’s recommendation of water, (3) 100%, three times the manufacturer’s recommendation of water, (4) 150%, 2.5 times the manufacturer’s recommendation of water, and (5) 200%, three times the manufacturer’s recommendation of water. For all three gypsum types, 50% water additions minimally affected the setting expansion and compressive modulus (p > 0.05), but lowered compressive strength by 26% to 52% (p < 0.05). Knoop hardness was lowered by 24% and 48% for Types V and III (p < 0.05), whereas Type IV was not significantly affected (p > 0.05). With few exceptions, the physical properties for the three gypsum types reached minimum values at 100% dilution, with few changes noted at higher dilutions. Increased W/P ratios did not adequately reduce the setting expansion and adversely affected other physical properties. Of the gypsums tested, Type IV is still recommended due to its lower setting expansion for full-arch implant master casts.

3 October 2021 in Prosthesis
Verified
Journal Article
Open access
PDF file
JSJames Sheets
James Sheets
DMDavid B. Marx
David B. Marx
NANina Ariani
Nina Ariani
VBValentim Barão
Valentim Barão
AWAlvin G. Wee
Alvin G. Wee
The objective was to compare the repeatability between dental faculty, whose clinical practice was primarily restorative dentistry, and final year dental students in categorizing the inherent translucency of images selected at random using either a 3- or 7-point scale (translucent to opaque). Digital images of anterior dentition were randomly selected based on inherent translucency. Thirty images (five were repeated) were randomized and categorized by 20 dental students and 20 faculty on their inherent translucency. Statistical analysis was performed using an F test for analysis of variance at 95% confidence interval. A covariance parameter estimate (CPE) was accomplished to compare the inter-rater variability of the dental faculty and dental students. Statistically, more variability occurred between Slides (CPE of 0.185 (p = 0.001)) and between Subject and Slide (CPE of 0.122 (p = 0.0002)) than within subjects (CPE of 0.021 (p = 0.083)). Viewing repeat Slides, Students (CPE = 0.16) were more consistent (p < 0.05) than faculty (CPE = 1.8) using the 3- point scale, while the CPE was the same (CPE = 0.669) using 7-point scale. Dental students and faculty were consistent using the 7-point scale to judge repeat slides, while dental students in this limited pilot study were more consistent when viewing a repeat slide using the 3-point scale.