There have been considerable recent technological developments for implant overdenture attachments. This study presents an overview of the biomechanical and biomolecular aspects of various attachments for implant overdenture. Available articles on attachments for implant overdenture were reviewed from January 1980 to August 2021 in the ScienceDirect, MEDLINE/PubMed, and Web of Science resources, and relevant studies were included in this study. We focused on the following topics: attachment systems, retention of various attachments, stress distribution with different attachments, the design and fabrication of attachments, digital techniques in overdenture attachments, and the effects of attachments in peri-implant health. We found that plastic resin is commonly used for ball and bar attachments, whereas nylon resin is commonly used in locator attachments. The locator system offers a valuable attachment option for implant-retained overdenture. Attachment retention reduces while lateral force increases with implant inclination in overdenture. The higher the retention of an overdenture attachment, the higher the transferred stresses. Additionally, clip loading produces more stress in implants and precision elements than bar-retained dentures. As such, we conclude that the ball and locator systems the best overdenture systems due to their superior tissue response, survival rate, and patient satisfaction.
Ridge resorption after tooth extraction may result in inadequate bone volume and unfavorable ridge architecture for ideal implant placement. The use of bone substitutes has been advocated to fill extraction sites and to enhance primary implant stability. This study was made to evaluate the clinical efficacy of novel 3D printed nano-porous hydroxyapatite (3DP HA, test group) in comparison to nano-crystalline bone graft (NanoBone®, control group) in alveolar ridge preservation prior to implant placement. Thirty patients were randomized into two groups following tooth extraction. All extracted sockets were filled with 3DP HA or NanoBone® and covered with a non-resorbable membrane. After four months, cone-beam computed tomography (CBCT) and intraoral scanner were used to measure dimensional changes of bone and soft tissue surface. Bone core specimens were harvested for histological analysis during implant osteotomy. Implant stability was assessed using a modified damping capacity analysis. At four months postoperatively, dimensional changes in soft tissue surface resorption were less in the test group than in the control group; however, alveolar bone resorption was the same in both groups. Histological analysis revealed new bone formation, residual graft and fibrous connective tissue in both groups. The average primary implant stability (IST) value for both groups was approximately 70. There was no statistically significant difference in all parameters between two groups (p > 0.05). 3DP HA could potentially be used as an alternative bone graft material for alveolar ridge preservation.
Objectives: The purposes of this study were to analyze the effects of single posterior implant restorations delivery on the redistribution of bite force and to evaluate the changes in occlusal force distribution of prostheses and potential influencing factors on occlusion variation at different stages. Materials and methods: Thirty-two single posterior restorations in 30 participants (18 women and 12 men aged 27 to 75 years) were placed into either a unilateral single-tooth defect (n = 17) or on either side of a bilateral teeth defects (n = 15). The bite force (%) of the prostheses, teeth and segments at the maximum intercuspation position (MIP) was evaluated using a T-scan at 5 stages (pre-placement, immediately following placement, and 2 weeks, 3 months, and 6 months post-placement). Results: The occlusal force of implant-supported prostheses was significantly (P = .000) lower than those of the control natural teeth at the baseline, then no significant difference was found with that of the mesial teeth at 3 months, and finally it was significantly (P = .000) lower than that of the distal teeth at 6 months; meanwhile, it significantly (P = .008) increased by a mean of 2.04 times from 2 weeks (3.39 ± 2.61%) to 3 months (6.90 ± 4.77%), whereas no significant difference (P = .900) was found from 3 months (6.90 ± 4.77%) to 6 months (7.31 ± 4.60%). In addition, the bite force of the posterior segment on the restored side of both unilateral and bilateral gaps was significantly (P = .013,.001) improved by 3.31% and 6.83%, respectively, although the discrepancy in bite force significantly (P = .039) increased from an initial 3.52% to 5.02% for subjects with bilateral defects, accompanying increases in the proportion (15.38%) of the level III bilateral bite force deviation (P >.05). Conclusions: Bite force and masticatory ability can be improved with the immediate delivery of a single posterior implant restoration. The bite force distributed on the implant prosthesis inevitably increases after placement of implant prostheses, a routine follow-up and occlusal evaluation are strongly needed.
23 November 2020 in Clinical Implant Dentistry and Related Research
The aims of this systematic review were to evaluate the clinical masticatory performance of implant-supported restorations, observe the occlusal force changes in the distribution of the implant res...
15 December 2022 in Clinical Implant Dentistry and Related Research