Objectives: The purposes of this study were to analyze the effects of single posterior implant restorations delivery on the redistribution of bite force and to evaluate the changes in occlusal force distribution of prostheses and potential influencing factors on occlusion variation at different stages. Materials and methods: Thirty-two single posterior restorations in 30 participants (18 women and 12 men aged 27 to 75 years) were placed into either a unilateral single-tooth defect (n = 17) or on either side of a bilateral teeth defects (n = 15). The bite force (%) of the prostheses, teeth and segments at the maximum intercuspation position (MIP) was evaluated using a T-scan at 5 stages (pre-placement, immediately following placement, and 2 weeks, 3 months, and 6 months post-placement). Results: The occlusal force of implant-supported prostheses was significantly (P = .000) lower than those of the control natural teeth at the baseline, then no significant difference was found with that of the mesial teeth at 3 months, and finally it was significantly (P = .000) lower than that of the distal teeth at 6 months; meanwhile, it significantly (P = .008) increased by a mean of 2.04 times from 2 weeks (3.39 ± 2.61%) to 3 months (6.90 ± 4.77%), whereas no significant difference (P = .900) was found from 3 months (6.90 ± 4.77%) to 6 months (7.31 ± 4.60%). In addition, the bite force of the posterior segment on the restored side of both unilateral and bilateral gaps was significantly (P = .013,.001) improved by 3.31% and 6.83%, respectively, although the discrepancy in bite force significantly (P = .039) increased from an initial 3.52% to 5.02% for subjects with bilateral defects, accompanying increases in the proportion (15.38%) of the level III bilateral bite force deviation (P >.05). Conclusions: Bite force and masticatory ability can be improved with the immediate delivery of a single posterior implant restoration. The bite force distributed on the implant prosthesis inevitably increases after placement of implant prostheses, a routine follow-up and occlusal evaluation are strongly needed.
The aims of this systematic review were to evaluate the clinical masticatory performance of implant-supported restorations, observe the occlusal force changes in the distribution of the implant res...
Objectives: The aim of this study is to evaluate the clinical performance of two types of retained dental implant therapy on the basis of Implant Quality Scale. Materials and methods: Thirty-five patients with 41cement-retained and 38 screw-retained implant restorations were evaluated using parameters including pain/sensitivity on function, mobility, marginal bone loss (MBL), probing depth (PD), plaque index (PI), sulcus bleeding index (SBI), peri-implant inflammation. Results: No pain but one implant-retained restoration of each group showed mobility. Probing depth of cement -retained group was higher than that of screw-retained group(P0.05), yet 2 screw-retained crowns were detected with bone loss of 2-3mm. The results of plaque index, sulcus bleeding index and inflammation demonstrated that the cement-retained group accounted for a higher proportion when same score, or a higher incidence in the higher grade. There were significant positive Spearman correlations among Plaque index, sulcus bleeding index and peri-implant inflammation. Conclusion: Compared with the screw-retained group, the cement-retained group showed similar failure rates but higher success rates. However, excess cement and adaptation of porcelain materials could strengthen plaque accumulation hence resulting in more severe inflammatory performance in the cement-retained group.
Heavy occlusal force and undesirable distribution of occlusal contacts may be factors of overloading, thus possibly leading to higher susceptibility to implant bone loss, implant fractures/loss, and prosthesis failures. The study intends to further analyze and evaluate the occlusal parameters including occlusion time(OT), disclusion time(DT), distribution of force, occlusion interference (OI) after insertion of posterior single implant, and regularly assess the occlusion changes to eliminate possible risk factors to achieve balanced occlusion and stability