Muhammad Ali

Mr. Muhammad Ali


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2020 in 2D Materials
Verified
Journal Article
Open access
PDF file
Zari TehraniZari Tehrani
Zari Tehrani
SWSimon Peter Whelan
Simon Peter Whelan
AMAlbertus Bernardus Mostert
Albertus Bernardus Mostert
JPJoão Vitor Paulin
João Vitor Paulin
MAMuhammad Ali
Muhammad Ali
CGCarlos FO Graeff
Carlos FO Graeff
The application of highly sensitive pH sensors manufactured in volume at low cost has great commercial interest due to an extensive array of potential applications. Such areas include industrial processing, biotechnology and medical diagnostics particularly in the development of point of care (POC) devices. A novel printable electrochemical pH sensor based on graphene and pigment melanin (PGM), was designed and produced by using a screen printing process that enables up scaling for potential commercial application. We demonstrate a highly sensitive pH sensor (62 mV pH−1 ± 7) over a pH range from 5 to 8, with high stability and superior performance when compared with a number of existing devices and making it suitable for physiological applications.

20 February 2021 in Nanoscale Advances
Verified
Journal Article
Open access
PDF file
Hina AbbasiHina Abbasi
Hina Abbasi
Zari TehraniZari Tehrani
Zari Tehrani
Anitha DevadossAnitha Devadoss
Anitha Devadoss
MAMuhammad Ali
Muhammad Ali
SMSoraya Moradi-Bachiller
Soraya Moradi-Bachiller
OGOwen Guy
Owen Guy
Development of ultra-thin polymer layer modified screen printed graphene electrodes with high conductivity for higher-sensitivity detection of Aβ(1–42) peptides with the lowest LOD of 1.4 pg mL −1 is presented.

5 March 2020 in 2D Materials
Verified
Journal Article
Open access
PDF file
FWFfion Walters
Ffion Walters
SRSergiy Rozhko
Sergiy Rozhko
DBDavid Buckley
David Buckley
EAEhsaneh Daghigh Ahmadi
Ehsaneh Daghigh Ahmadi
MAMuhammad Ali
Muhammad Ali
OGOwen James Guy
Owen James Guy
A hybrid biosensor based on a graphene resistor functionalized with self-assembled Graphene-AuNPs (Gold Nanoparticles) is demonstrated for the real-time detection of hepatitis B surface antigen (HBsAg). The hybrid biosensor consists of a ssDNA sequence attached to a graphene resistor device via π–π stacking interactions in combination with a ssDNA functionalized AuNP. The ssDNA has complementary sequences which through hybridization, yield the graphene-AuNP hybrid biosensor. Real-time 2-point resistance measurements, performed using varying concentrations of HBsAg, show a linear dependence of resistance change against the logarithm of HBsAg concentration (log[HBsAg]). A limit of detection of 50 pg ml−1 was observed. Moreover, the hybrid biosensor platform has potential to be applied to any biomarker of interest.

16 March 2021 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
HSHugo Spieser
Hugo Spieser
Zari TehraniZari Tehrani
Zari Tehrani
MAMuhammad Ali
Muhammad Ali
EAEhsaneh Daghigh Ahmadi
Ehsaneh Daghigh Ahmadi
ADAurore Denneulin
Aurore Denneulin
DGDavid Gethin
David Gethin
The application of sensitive gas sensors manufactured in high volume at low cost is of great interest due to an extensive array of potential applications.

20 August 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
MAMuhammad Ali
Muhammad Ali
JMJacob Mitchell
Jacob Mitchell
GBGregory Burwell
Gregory Burwell
KRKlaudia Rejnhard
Klaudia Rejnhard
CJCerys Anne Jenkins
Cerys Anne Jenkins
OGOwen Guy
Owen Guy
Graphene-based point-of-care (PoC) and chemical sensors can be fabricated using photolithographic processes at wafer-scale. However, these approaches are known to leave polymer residues on the graphene surface, which are difficult to remove completely. In addition, graphene growth and transfer processes can introduce defects into the graphene layer. Both defects and resist contamination can affect the homogeneity of graphene-based PoC sensors, leading to inconsistent device performance and unreliable sensing. Sensor reliability is also affected by the harsh chemical environments used for chemical functionalisation of graphene PoC sensors, which can degrade parts of the sensor device. Therefore, a reliable, wafer-scale method of passivation, which isolates the graphene from the rest of the device, protecting the less robust device features from any aggressive chemicals, must be devised. This work covers the application of molecular vapour deposition technology to create a dielectric passivation film that protects graphene-based biosensing devices from harsh chemicals. We utilise a previously reported “healing effect” of Al2O3 on graphene to reduce photoresist residue from the graphene surface and reduce the prevalence of graphene defects to improve graphene device homogeneity. The improvement in device consistency allows for more reliable, homogeneous graphene devices, that can be fabricated at wafer-scale for sensing and biosensing applications.

10 September 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
FWFfion Walters
Ffion Walters
MAMuhammad Ali
Muhammad Ali
GBGregory Burwell
Gregory Burwell
SRSergiy Rozhko
Sergiy Rozhko
Zari TehraniZari Tehrani
Zari Tehrani
OGOwen Guy
Owen Guy
Affinity biosensors based on graphene field-effect transistor (GFET) or resistor designs require the utilization of graphene’s exceptional electrical properties. Therefore, it is critical when designing these sensors, that the electrical properties of graphene are maintained throughout the functionalization process. To that end, non-covalent functionalization may be preferred over covalent modification. Drop-cast 1,5-diaminonaphthalene (DAN) was investigated as a quick and simple method for the non-covalent amine functionalization of carbon-based surfaces such as graphene, for use in biosensor development. In this work, multiple graphene surfaces were functionalized with DAN via a drop-cast method, leading to amine moieties, available for subsequent attachment to receptor molecules. Successful modification of graphene with DAN via a drop-cast method was confirmed using X-ray photoelectron spectroscopy (XPS), Raman spectroscopy and real-time resistance measurements. Successful attachment of receptor molecules also confirmed using the aforementioned techniques. Furthermore, an investigation into the effect of sequential wash steps which are required in biosensor manufacture, on the presence of the DAN layer, confirmed that the functional layer was not removed, even after multiple solvent exposures. Drop-cast DAN is thus, a viable fast and robust method for the amine functionalization of graphene surfaces for use in biosensor development.