Philipp Roesch

Dr. Philipp Roesch


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
PRPhilipp Roesch
Philipp Roesch
CVChristian Vogel
Christian Vogel
Franz-Georg SimonFranz-Georg Simon
Franz-Georg Simon
Over the past two decades, per- and polyfluoroalkyl substances (PFASs) have emerged as worldwide environmental contaminants, calling out for sophisticated treatment, decomposition and remediation strategies. In order to mineralize PFAS pollutants, the incineration of contaminated material is a state-of-the-art process, but more cost-effective and sustainable technologies are inevitable for the future. Within this review, various methods for the reductive defluorination of PFASs were inspected. In addition to this, the role of mechanochemistry is highlighted with regard to its major potential in reductive defluorination reactions and degradation of pollutants. In order to get a comprehensive understanding of the involved reactions, their mechanistic pathways are pointed out. Comparisons between existing PFAS decomposition reactions and reductive approaches are discussed in detail, regarding their applicability in possible remediation processes. This article provides a solid overview of the most recent research methods and offers guidelines for future research directions.

3 December 2021 in Environmental Science and Pollution Research
Verified
Journal Article
Open access
PDF file
PRPhilipp Roesch
Philipp Roesch
CVChristian Vogel
Christian Vogel
THThomas Huthwelker
Thomas Huthwelker
PWPhilipp Wittwer
Philipp Wittwer
FSFranz-Georg Simon
Franz-Georg Simon
For the first time, fluorine K-edge X-ray absorption near-edge structure (XANES) spectroscopy was applied to detect per- and polyfluoroalkyl substances (PFAS) in various soil and sewage sludge samples. The method can be used to determine the speciation of inorganic and organic fluorides, without pre-treatment of solid samples. Therefore, XANES spectra of several inorganic fluorides as well as selected fluorinated organic compounds were recorded. While inorganic fluorides partially exhibit a variety of sharp spectral features in the XANES spectrum, almost all inspected organofluorine compounds show two distinct broad features at 688.5 and 692.0 eV. Moreover, the peak intensity ratio 688.5 eV/692.0 eV in the PFAS XANES spectrum can be inversely correlated to the chain length of the perfluoro sulfonic acid group. The detection of targeted PFAS by bulk-XANES spectroscopy in combination with linear combination fitting in soils and sewage sludges was not applicable due to the low organic fluorine to total fluorine ratio of the samples (0.01–1.84%). Nonetheless, direct analysis of pure PFAS revealed that analysis of organofluorine species might be achieved in higher concentrated samples. Furthermore, quantitative measurements by combustion ion chromatography (CIC) evaluated as sum parameters extractable organically bound fluorine (EOF) and total fluorine (TF) emphasize that besides soils, sewage sludges are a significant source of organic fluorine in agriculture (154–7209 µg/kg).

7 November 2023 in Environmental Science & Technology
Verified
Journal Article
Open access
BRBridger J. Ruyle
Bridger J. Ruyle
HPHeidi M. Pickard
Heidi M. Pickard
LSLara Schultes
Lara Schultes
FFFelicia Fredriksson
Felicia Fredriksson
AHAmy L. Heffernan
Amy L. Heffernan
Elsie M. SunderlandElsie M. Sunderland
Elsie M. Sunderland
Research on per- and polyfluoroalkyl substances (PFAS) frequently incorporates organofluorine measurements, particularly because they could support a class-based approach to regulation. However, standardized methods for organofluorine analysis in a broad suite of matrices are currently unavailable, including a method for extractable organofluorine (EOF) measured using combustion ion chromatography (CIC). Here, we report the results of an international interlaboratory comparison. Seven laboratories representing academia, government, and the private sector measured paired EOF and PFAS concentrations in groundwater and eel (Anguilla rostrata) from a site contaminated by aqueous film-forming foam. Among all laboratories, targeted PFAS could not explain all EOF in groundwater but accounted for most EOF in eel. EOF results from all laboratories for at least one replicate extract fell within one standard deviation of the interlaboratory mean for groundwater and five out of seven laboratories for eel. PFAS spike mixture recoveries for EOF measurements in groundwater and eel were close to the criterion (±30%) for standardized targeted PFAS methods. Instrumental operation of the CIC such as replicate sample injections was a major source of measurement uncertainty. Blank contamination and incomplete inorganic fluorine removal may introduce additional uncertainties. To elucidate the presence of unknown organofluorine using paired EOF and PFAS measurements, we recommend that analysts carefully consider confounding methodological uncertainties such as differences in precision between measurements, data processing steps such as blank subtraction and replicate analyses, and the relative recoveries of PFAS and other fluorine compounds.

12 July 2023 in Environmental Science: Processes & Impacts
Verified
Journal Article
Closed access
PDF file
JZJonathan Zweigle
Jonathan Zweigle
CCCatharina Capitain
Catharina Capitain
FSFabian Simon
Fabian Simon
PRPhilipp Roesch
Philipp Roesch
BBBoris Bugsel
Boris Bugsel
CZChristian Zwiener
Christian Zwiener
Per- and polyfluoroalkyl substances (PFAS) are widely used for durable water-repellent finishing of different fabrics and textiles such as outdoor clothing, carpets, medical textiles and more. Existing PFAS extraction techniques followed by target analysis are often insufficient for detecting widely used side-chain fluorinated polymers (SFPs) that are barely or non-extractable. SFPs are typically copolymers consisting of a non-fluorinated backbone with perfluoroalkyl side-chains to obtain desired properties. We compared the accessible analytical information and performance of complementary techniques based on oxidation (dTOP and PhotoTOP assays), hydrolysis (THP assay), standard extraction, extractable organic fluorine (EOF), and total fluorine (TF) with five functional textiles and characterized 7 further textiles only by PhotoTOP oxidation. The results show that when applied directly to textile samples, dTOP and PhotoTOP oxidation and also hydrolysis (THP) are able to capture large fractions of TF in the form of perfluoroalkyl side-chains present in the textiles while methods relying on extracts (EOF, target and non-target analysis) yield much lower fractions of TF (e.g., factor ∼25–50 lower). The conversion of large fractions of the measured TF into PFCAs or FTOHs from fluorinated side chains is in contrast to previous studies. Concentrations ranged from <LOQ to over ∼1000 mg F kg−1 after oxidation/hydrolysis and <LOQ to over 2000 mg F kg−1 for TF, while EOF and target PFAS in extracts were detected at much lower concentrations (up to ∼60 mg F kg−1) (amount of fluorine is in the order: extraction ≪ EOF ≪ oxidation/hydrolysis ≤ TF). Perfluoroalkyl carboxylic acids (PFCAs) and fluorotelomer alcohols (FTOHs) from THP hydrolysis and PhotoTOP oxidation both represented chain-length distribution in the textiles showing that long-chain SFPs are still used in current textiles. Further advantages and disadvantages of the applied methods are discussed.

14 January 2024 in Chemosphere
Verified
Journal Article
Open access
PRPhilipp Roesch
Philipp Roesch
ASAndrea Schinnen
Andrea Schinnen
MRMaren Riedel
Maren Riedel
TSThomas Sommerfeld
Thomas Sommerfeld
GSGeorge Sawal
George Sawal
Franz-Georg SimonFranz-Georg Simon
Franz-Georg Simon
Here, we report a comparative study of different sum parameter analysis methods for the extraction of per- and polyfluoroalkyl substances (PFAS) from manufactured consumer products, which can be measured by combustion ion chromatography (CIC). Therefore, a hydrolysis-based extraction method was further developed, which accounts for the addition of hydrolyzable covalently bound polyfluoroalkylated side-chain polymers (SFPs) to the extractable organic fluorine portion of the mass balance proposed as "hydrolyzable organically bound fluorine" (HOF). To test this hypothesis, the method was applied to 39 different consumer products containing fluoropolymers or monomeric PFAS taken from four different categories: outdoor textiles, paper packaging, carpeting, and permanent baking sheets. We also evaluated the method's efficiency by extracting four synthesized fluorotelomer polyacrylate reference compounds. The total fluorine (TF) and extractable organically bound fluorine (EOF) values were measured through CIC using established protocols. The TF values ranged from sub-ppb to %-levels, depending on the compound class. All samples showed results for hydrolyzed organofluorine (HOF) between 0.03 and 76.3 μg/g, while most EOF values were lower (<LOD to 58.1 μg/g). Moreover, the methods were contrasted with the "total hydrolyzable precursor" (THP) assay analyzed using gas-chromatography coupled mass spectrometry (GC-MS), which yielded concentrations of 6:2-10:2 fluorotelomer alcohols (<LOD-568 μg/g) for textile and paper samples. Furthermore, targeted analytical investigation of 25 compounds via liquid chromatography coupled tandem mass spectrometry (LC-MS/MS) was conducted and accounted for significantly lower sum amounts (<LOD-0.98 μg PFAS/g). To estimate the fluorine mass balance of all methods, the fluorine levels of target analytical data were calculated and compared to the sum parameter values and evaluated. Finally, the efficiency of the extraction method was approximated by the recovery analysis of four selected SFP model compounds compared to their TF values, yielding 36.7-74.0% after extraction and 3.8-36.3% after processing the extract for the HOF sum parameter.

26 May 2023 in Environmental Science: Processes & Impacts
Verified
Journal Article
Open access
PDF file
PRPhilipp Roesch
Philipp Roesch
CVChristian Vogel
Christian Vogel
PWPhilipp Wittwer
Philipp Wittwer
THThomas Huthwelker
Thomas Huthwelker
CBCamelia N. Borca
Camelia N. Borca
Franz-Georg SimonFranz-Georg Simon
Franz-Georg Simon
An X-ray based surface analytical method allows for an unprecedented perspective on a known substance class and can contribute to localization and comprehension of fluorinated pollutant distribution in PFAS-containing matrices.