Pablo Vega-Garcia

Mr. Pablo Vega-Garcia

Technical University Munich
+1

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2020 in Water
Verified
Journal Article
Open access
PDF file
Pablo Vega-GarciaPablo Vega-Garcia
Pablo Vega-Garcia
RSRegina Schwerd
Regina Schwerd
CSChristian Rudolf Scherer
Christian Rudolf Scherer
CSChristoph Schwitalla
Christoph Schwitalla
Brigitte HelmreichBrigitte Helmreich
Brigitte Helmreich
Leaching outdoor tests (LOT) are commonly used to assess the leaching of substances from construction materials. In this context, the amount of stormwater in contact with the surface material is of special interest for analyzing the runoff loads of substances from building façades. A numerical model was developed in MATLAB on the basis of previous analytical models to calculate the collected stormwater runoff volumes from the vertical test panels (VTP) during LOT. In the model, wind-driven rain (WDR) is considered to be the main mechanism for determining the amount of water impinging on the VTP, so it is a crucial factor in the modeling for the façade runoff. The new model makes it possible to simulate the runoff volumes from VTP that are covered with a wide variety of plaster and mortar. Using the new model, it was possible to relate the VTP runoff volumes obtained during an 18-month sampling period for LOTs performed at the Fraunhofer Institute for Building Physics in Valley, Germany. When comparing the simulation results with the field test accumulated runoffs, the model exhibited a difference of no more than 3.5% for each of the analyzed materials. The simulation results are satisfying, and the paper demonstrates the feasibility of the modelling approach for the runoff assessment of VTP covered with a variety of plaster and mortar.

11 October 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
ASAndreas Schmohl
Andreas Schmohl
MBMichael Buschhaus
Michael Buschhaus
VNVictor Norrefeldt
Victor Norrefeldt
SJSabine Johann
Sabine Johann
ABAndrea Burdack-Freitag
Andrea Burdack-Freitag
CSChristoph Schwitalla
Christoph Schwitalla
The investigation of the cleaning effectiveness of air cleaners under realistic conditions is challenging. Mathematical models are needed to extract characteristic properties of the air cleaning system from experimental data. An incremental evaluation model based on a source term and a total first-order loss coefficient in each segment was developed to analyze indoor particle measurements. The application of the model is demonstrated using two scenarios, one in a well-mixed testing room and another in a fully equipped aircraft cabin at 750 hPa with a typical aircraft ventilation system. In the first scenario, a normalized version of the model is used to eliminate the source’s influence. For the investigation in the aircraft cabin, the model served to extract temporal and spatial resolved source terms and first-order loss coefficients. The incremental evaluation model is applicable to enhance the certification of air cleaners. The application of the model is not only limited to particles; measurements of gaseous compounds like ozone, carbon dioxide, or volatile organic compounds can be evaluated analogously. The model’s utility for the data analysis of experiments with complex flow conditions should be studied in further investigations.

8 January 2025 in Journal of Environmental Management
Verified
Journal Article
Open access
LWLia Weiler
Lia Weiler
Pablo Vega-GarciaPablo Vega-Garcia
Pablo Vega-Garcia
AVAnya Vollpracht
Anya Vollpracht
Many construction products are in contact with, e.g., rain and seepage water during their service life. As a result, they may leach and release potentially harmful substances into the environment. Harmonized laboratory tests are available to assess the potential environmental impact, but the evaluation of leaching test results remains challenging because releases found in laboratory experiments cannot be directly extrapolated to field conditions. Particularly complex is the case of irrigated and therefore intermittently wetted components. This paper presents the leaching results of a one-year outdoor irrigation of a fly ash concrete doped with heavy metals (arsenic, lead, cadmium, chromium, copper, nickel, thallium, vanadium, and zinc). The results are compared with those of two other outdoor irrigation studies: a high-density concrete and a facing masonry mortar. Two modeling approaches, a statistical method by Weiler et al. and a thermodynamic model of Vega Garcia et al. are used to model the incremental and cumulative releases and to compare their applicability and predictive value. The experimental data of this work confirm the well-known fact that cementitious phases effectively incorporate many potentially environmentally harmful substances. However, increased leaching, particularly outdoors, is observed for the oxyanion-forming elements arsenic, chromium, vanadium, and sulfur. Both models seem sufficient for depicting and, in the case of statistics, also to predict the magnitude of the measured values. However, while the statistical approach focuses only on the results and requires further verification data and factor development for different materials, the thermodynamic approach describes the geochemical processes and therefore requires more background knowledge of the operator; it also lacks predictive accuracy for the irrigation case. Further research is needed.