The current pandemic of the SARS-CoV-2 virus requires measures to reduce the risk of infection. In addition to the usual hygiene measures, air cleaners are a recommended solution to decrease the viral load in rooms. Suitable technologies range from pure filters to inactivating units, such as cold plasma or UVC irradiation. Such inactivating air cleaners, partly combined with filter technology, are available on the market in various designs, dimensions and technical specifications. Since it is not always clear whether they may produce undesirable by-products, and the suitability for particular applications cannot be assessed on the basis of the principle of operation, the effectivity of six inactivating devices was investigated in a near-real environment. The investigations were based on a standard method published by the VDI. The procedure was extended in such a way that a permanent virus source was simulated, which corresponds to the presence of a person suffering from COVID-19 in a room. The study addresses the difference of the mere presence of viruses to the determination of the virulence. As a result, a deep understanding is provided between the behavior of a virus as a pure aerosolized particle and its real infectivity in order to enable the assessment of suitable air cleaners.
Leaching outdoor tests (LOT) are commonly used to assess the leaching of substances from construction materials. In this context, the amount of stormwater in contact with the surface material is of special interest for analyzing the runoff loads of substances from building façades. A numerical model was developed in MATLAB on the basis of previous analytical models to calculate the collected stormwater runoff volumes from the vertical test panels (VTP) during LOT. In the model, wind-driven rain (WDR) is considered to be the main mechanism for determining the amount of water impinging on the VTP, so it is a crucial factor in the modeling for the façade runoff. The new model makes it possible to simulate the runoff volumes from VTP that are covered with a wide variety of plaster and mortar. Using the new model, it was possible to relate the VTP runoff volumes obtained during an 18-month sampling period for LOTs performed at the Fraunhofer Institute for Building Physics in Valley, Germany. When comparing the simulation results with the field test accumulated runoffs, the model exhibited a difference of no more than 3.5% for each of the analyzed materials. The simulation results are satisfying, and the paper demonstrates the feasibility of the modelling approach for the runoff assessment of VTP covered with a variety of plaster and mortar.
The investigation of the cleaning effectiveness of air cleaners under realistic conditions is challenging. Mathematical models are needed to extract characteristic properties of the air cleaning system from experimental data. An incremental evaluation model based on a source term and a total first-order loss coefficient in each segment was developed to analyze indoor particle measurements. The application of the model is demonstrated using two scenarios, one in a well-mixed testing room and another in a fully equipped aircraft cabin at 750 hPa with a typical aircraft ventilation system. In the first scenario, a normalized version of the model is used to eliminate the source’s influence. For the investigation in the aircraft cabin, the model served to extract temporal and spatial resolved source terms and first-order loss coefficients. The incremental evaluation model is applicable to enhance the certification of air cleaners. The application of the model is not only limited to particles; measurements of gaseous compounds like ozone, carbon dioxide, or volatile organic compounds can be evaluated analogously. The model’s utility for the data analysis of experiments with complex flow conditions should be studied in further investigations.
Facade coatings used in external thermal insulation composite systems (ETICS) are commonly protected against microbial growth by biocides that can leach into the environment. To support the development of biocide‑free products, we developed a rapid weathering method that enables assessment of the resistance of facade coatings to microbial growth. ETICS specimens are mounted in a climate chamber and exposed for 100 days to a controlled climate simulating an average Central European autumn day. Surface temperatures of the specimens are actively regulated to fall below the dew point for 8 ± 1 h per day, generating condensation that promotes microbial growth. Natural colonization is simulated by regular inoculation with a defined suspension of algae and mold. Microbial development is documented throughout the test and quantified using a 10-level rating scale that captures both growth onset and intensity. Application of the method to a range of ETICS compositions demonstrated high discriminatory power and good reproducibility. The procedure is proposed for rapid, laboratory-based comparison of biocide-free ETICS concerning their resistance to facade contamination by microorganisms.