This article describes a novel electrochemical on-chip biosensor that utilises the anti-PSA antibody (Ab) and silver nanoparticles (AgNPs) to enhance the sensing and detection capability of the prostate-specific antigen (PSA) in the blood. The AgNPs are prepared, characterised, and applied to a silicon photonic on-chip biosensing receptor platform designed to enhance the accurate detection of PSA. The AgNPs were synthesised by a chemical reduction method using silver nitrate (AgNO3) as the precursor. Transmission electron microscopy (TEM), selected area electron diffraction (SAED), energy dispersion X-ray spectroscopy (EDS), small angle X-ray scattering (SAXS), X-ray diffraction (XRD), and light microscopy were among the methods used in the characterisation and analysis of the AgNPs. Each stage of the immunosensor fabrication was characterised using cyclic voltammetry. The proposed immunosensor was applied in the detection of PSA, a prostate cancer biomarker, with a high sensitivity and a limit of detection of 0.17 ng/mL over a linear concentration range of 2.5 to 11.0 ng/mL. The immunosensor displayed good stability and was selective in the presence of interfering species like immunoglobulin (Ig) in human serum, ascorbic acid (AA), and diclofenac (Dic). The detectivity and sensitivity are significantly higher than previous reports on similar or related technologies.
Nanomaterials integration in biosensors designs are known to enhance sensing and signaling capabilities by exhibiting remarkably high surface area enhancement and intrinsic reactivity owing to their distinctive optical, chemical, electrical and catalytic properties. We present the synthesis and characterization of silver nanoparticles (AgNPs), and their immobilization on a silicon on-chip biosensor platform to enhance sensing capability for prostate specific antigen (PSA) - cancer biomarkers. Several techniques, including UV-Visible (UV-Vis) absorption spectrum, Fourier transforms infrared spectroscopy (FTIR), high resolution transmission electron microscopy (HRTEM), scanning electron microscopy (SEM) and field emission scanning electron microscopy (FESEM) were used for characterizing the AgNPs. The biochemical sensor consists of AgNPs immobilized on the receptor layer of a silicon avalanche mode light emitting device (Si AM LED) which enables on-chip optical detection biological analytes. A bio-interaction layer etched from the chip interacts with the evanescent field of a micro dimensioned waveguide. An array of detectors below the receptor cavity selectively monitor reflected light in the UV, visible, infrared and far infrared wavelength regions. AgNPs used as an immobilization layer in the receptor layer enhances selective absorption analytes, causing a change in detection signal as a function of propagation wavelength as light is dispersed. The analytes could range from gases to cancer biomarkers like prostate specific antigen.
A two-junction micro p+np+ silicon avalanche-mode light-emitting device (Si AMLED) is analyzed for its dispersion characteristics, which generally resulted in different wavelengths of light (colors) being emitted at different angles from the surface of the device. The SiAMLED is integrated into on-chip bipolar radio frequency-integrated circuitry at micron dimensions. LEDs have high-frequency modulation frequencies reaching into the GHz range. Such devices, which are of micron dimension, operate at 8 to 10 V, 1 μA to 2 mA. The emission wavelength is in the 450- to 850-nm range, emission spot sizes are about 1 μm2, and emission intensities are up to 200 nW . μm − 2. The observed geometrical-chromatic dispersion characteristics range from 0.01 deg / nm wavelength for green radiation at a 5 deg exit angle to the normal of the device to 0.16 deg / nm wavelength for blue radiation at a 60 deg exit angle to the normal of the surface of the device. The high dispersion characteristics of the emitted radiation are attributed to the positioning of the optical source ∼1 μm subsurface to the silicon–silicon oxide interface, as well as to the high-refractive index differences between silicon and the surrounding lower refractive index silicon oxide layers. It is believed that the identified dispersion characteristics will have interesting and futuristic on-chip electro-optic applications for on-chip micro-optical wavelength dispersers, futuristic optical communication demultiplexers, along with on-chip microgas and biosensor applications.
This article describes a novel electrochemical on-chip biosensor that utilizes anti-PSA antibody (Ab) and silver nanoparticles (AgNPs) to enhance the sensing and detection capability of prostate specific antigen (PSA) in the blood. The AgNPs are prepared, characterized, and applied onto a silicon photonic on-chip biosensing receptor platform designed to enhance the accurate detection of PSA. The AgNPs were synthesized by a chemical reduction method using silver nitrate (AgNO3) as the precursor. Transmission electron microscopy (TEM), selected area electron diffraction (SAED), energy dispersion X-ray spectroscopy (EDS), small angle X-ray scattering (SAXS), X-ray diffraction (XRD), and light microscopy were among the methods used in the characterization and analysis of the AgNPs. Each stage of the immunosensor fabrication was characterized using cyclic voltammetry. The proposed immunosensor was applied in the detection of PSA, a prostate cancer biomarker, with a high sensitivity and a limit of detection of 0.17 ng/mL over a linear concentration range of 2.5 to 11.0 ng/mL. The immunosensor displayed good stability and was selective in the presence of interfering species like immunoglobulin (Ig) in human serum, ascorbic acid (AA), and diclofenac (Dic). The detectivity and sensitivity are significantly higher than previous reports on similar or related technologies.
An electrochemical immunosensor for the quantification of prostate-specific antigens (PSAs) using silver nanocrystals (AgNCs) is reported. The silver nanocrystals were synthesized using a conventional citrate reduction protocol. The silver nanocrystals were characterized using scanning electron microscopy (SEM) and field effect scanning electron microscopy (FESEM), X-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM), Fourier-transform infrared spectroscopy (FTIR), UV-Vis spectroscopy, and small-angle X-ray scattering (SAXS). The proposed immunosensor was fabricated on a glassy carbon electrode (GCE), sequentially, by drop-coating AgNCs, the electro-deposition of EDC-NHS, the immobilization of anti-PSA antibody (Ab), and dropping of bovine serum albumin (BSA) to prevent non-specific binding sites. Each stage of the fabrication process was characterized by cyclic voltammetry (CV). Using square wave voltammetry (SWV), the proposed immunosensor displayed high sensitivity in detecting PSA over a concentration range of 1 to 10 ng/mL with a detection limit of 1.14 ng/mL and R2 of 0.99%. The immunosensor was selective in the presence of interfering substances like glucose, urea, L-cysteine, and alpha-methylacyl-CoA racemase (AMACR) and it showed good stability and repeatability. These results compare favourably with some previously reported results on similar or related technologies for PSA detection.
An electrochemical immunosensor for the quantification of prostate specific antigens (PSA) using silver nanocrystals (AgNCs) is reported. The silver nanocrystals were synthesized using a conventional citrate reduction protocol. The silver nanocrystals were characterized using scanning electron microscopy (SEM) and field effect scanning electron microscopy (FESEM), x-ray diffraction (XRD), high-resolution transmission electron microscopy (HRTEM), Fourier transform infrared spectroscopy (FTIR), UV-Vis spectroscopy, and small angle X-ray scattering (SAXS). The proposed immunosensor was fabricated on a glassy carbon electrode (GCE) sequentially by drop-coating AgNCs, the electro-deposition of EDC-NHS, the immobilization of anti-PSA antibody (Ab), and dropping of bovine serum albumin (BSA) to prevent non-specific binding sites. Each stage of the fabrication process was characterized by cyclic voltammetry (CV). Using square wave voltammetry (SWV), the proposed immunosensor displayed high sensitivity in detecting PSA over a concentration range of 1 to 10 ng/mL with a detection limit of 1.14 ng/mL and R2 of 0.99%. The immunosensor was selective in the presence of interfering substances like glucose, urea, L-cysteine, and alpha-methylacyl-CoA racemases (AMACR) and it showed good stability and repeatability. These results compare favourably with some previously reported results on similar or related technologies for PSA detection.