A wind tunnel is an essential device for aerodynamic modeling and measurement. High cost and relatively huge size with no open market design hinder the wind tunnel from being widely available in laboratory design for universities and small R&D companies, particularly in a developed country with limited research funding. Thus, most aerodynamic modeling and measurement are done by simulating through computer software which leads to high deviation as the nature of wind is unpredictable. This project aims to provide an open design for a relatively low-cost wind tunnel that universities and R&D companies can quickly adapt. An open design for an open-loop wind tunnel is presented in this article. The proposed wind tunnel design is specifically intended to help the researcher with the aerodynamic measurement with minimum cost for building, customizable design, and reliable measurement. The components, parts, and equipment use the widely available part, which can be obtained across the globe. Validation and characterization are done using software simulation and actual measurement through the device. The proposed design can meet the criteria for aerodynamic measurement and can help the researcher provide a better analysis by combining the actual measurement and software simulation.
23 September 2021 in EUREKA: Physics and Engineering
Paraffin is well known thermal energy storage with the high latent heat of fusion. Unfortunately, low thermal conductivity and low melting temperature inhibit large-scale applications for lower temperature applications like solar water heaters and desalination. The addition of high thermal conductivity material can increase the thermal conductivity of paraffin and increase the melting temperature of paraffin. In this study, a new approach is taken by using volcanic sand as thermal conductivity enhancement material. The properties of the sand are examined. The chemical composition of the sand is dominated by Fe (51.23 %), Fe2O3 (23.24 %) and SiO2 (11 %), which are known as good thermal conductivity materials. Six different compositions of paraffin/sand (weight ration) are tested to observe the melting and vapor temperature of the composite. Adding sand (with granule size of 44 µm) by 30 wt % can accelerate the charging rate by 25 % compared to pure paraffin, where the discharging rate is increased significantly by 17.8 %. The supercooling degree of the composite is only 1 °C, where pure paraffin has a supercooling degree by 8 °C. The charging and discharging characteristics for each sample are discussed in detail within the article. Overall, the addition of volcanic sand improves paraffin's charging and discharging rate, reducing the supercooling degree and can be considered a convenient method to improve the paraffin performance as latent heat storage
31 December 2022 in International Journal of Heat and Technology
Paraffin-based latent heat storage has a higher thermal capacity than sensible heat storage. Despite that, the actual implementation of paraffin as an active latent heat storage (ALHS) system is limited due to low charging and discharging rate with unequal temperature distribution as the impact of mushy region formation. The present study evaluates the finned-coil heat exchanger for the ALHS tank to overcome the related problems. Three finned-coil configurations are tested experimentally: straight-fin, branched-fin and height-fin. The evaluation uses the ALHS arrangement to assess each configuration's charging/discharging rate. The branched fin provides an equal thermal distribution, promoting a higher final temperature of 112.3°C. It also achieves the highest power rate of 250.5 Watts. The height-fin minimizes the effect of void formation, which maintains a sufficient heat transfer rate during the discharging. However, the average power rate for each model is relatively low. The finding indicates that it is essential to provide adequate heat transfer for the center part of the tank, including adding a branched fin along with coil turn to provide a better heat transfer rate. It boosts the charging/discharging rate, making the system's response time desirable to achieve effective power during the operation.
Reactivation of an old oil well can be explicitly calculated to maximize crude oil production. The biggest challenge with the activation process is the crude oil content in old wells, which is not feasible to meet the specified minimum standards. In the case of the Bunian oil field, Indonesia, the crude oil produced has high water content. It causes a decrease in the quality of production and also hinders production capacity. The production scheme applied to the Bunian field has a storage tank that functions to reduce water content using the gravity method, but this is less effective. Let’s modify the storage tank into a heat exchanger tank through the engineering design process and labeled it as a free water knockout tank (FWKO). The FWKO is made of a multi-pass tube heat exchanger. The experiments are conducted through three phases’ tests before deciding the final design. From the test, the change in water content is varied with temperature differences of the working fluid and crude oil. The lowest water content is obtained at 0.5 % at final tests. After analyzing the characteristic of each test result, the final design is taken by adjusting the suitable working fluid temperature and pressure. Finally, by using suitable parameters, the average water content of crude oil is decreased up to the minimum requirement (<0.1 %). The design of FWKO is considered simple with an excellent performance and can adapted easily. The FWKO able to process crude oil with water content <20 %, where it suitable for waxy oil well. The working fluid can be processed both in liquid and gas state. Furthermore, the heating source for the working fluid is gained from the gas flare by using thermic heater. Thus, it does not require an extra heating source for the heat exchanger
20 September 2020 in International Journal on Advanced Science, Engineering and Information Technology
This study evaluated seven potential locations for wind energy in Indonesia. This study applied economic analysis using static analysis and the Monte Carlo simulation. The later was used to measure the financial indicators and then to analyze the sensitivity of economic uncertainties. The result findings show that in term of annual energy production volume among the seven selected locations, Jeneponto location has the highest value of 4,339,003.2 MWh with a capacity factor of 25.22% and Bantul location has the lowest value of 526,476 MWh with a capacity factor of 16.51%. According to economic uncertainty analysis, the highest NPV and attractive IRR values with high deviation standard values will be interesting to the risk-taking investors. Otherwise, the lowest NPV and IRR values fit the risk of avoiding-type investors due to its low deviation standard values. Based on sensitivity analysis, the increase of average NPV and IRR values of all seven locations are influenced positively by first 5-year of the selling price, which contributes approximately 30% and 50% of NPV and IRR’s percentage change. By contrast, the decrease in average NPV values of all seven locations is influenced by the discount rate, which contributes approximately 15% of NPV’s percentage change. Meanwhile, the decrease in average IRR is influenced by capital investment cost, which contributes approximately 20% of IRR’s percentage change. Policymakers can further consider the parameters mentioned above.
28 February 2023 in Eastern-European Journal of Enterprise Technologies
The present work is specifically focused on the form stability of paraffin as a phase change material (PCM) through the addition of high-density polyethylene (HDPE). The aim of adding HDPE is to obtain a stable form of paraffin during the phase transition. Moreover, improving the performance of PCM leads to an advanced operation of the latent heat storage unit with an excellent charging duration and response time. The study uses HDPE at a ratio of 5 wt %, 10 wt % and 15 wt %. The results indicate significant differences between the form-stable PCM (FSPCM) and pure paraffin. For instance, the supercooling degree is decreased with the addition of HDPE, where paraffin has a supercooling degree of 8.01 °C while FSPCM with 15 wt % HDPE has a supercooling degree of 3.73 °C. The latent heat of fusion by adding 10 wt % and 15 wt % HDPE is slightly decreased by 1.85 %, which is much lower compared to adding 5 wt % HDPE, which reduces the latent heat of fusion by about 6.02 %. Adding HDPE leads to a faster charging process and a better response time during the discharging process. The charging rate is increased significantly by adding 15 wt % HDPE with a substantial increment of around 40 % with an average charging rate of 2.39 °C/min. The heat release during the discharging process is increased for FSPCM with 5 wt % HDPE where the temperature drops by more than 70 °C within 20 minutes. The findings indicate that adding HDPE contributed positively to reducing the supercooling degree and providing a steady phase transition. Thus, the heat exchange process of paraffin is more favorable, which improves the performance of the latent heat storage unit. Furthermore, the operation can be improved significantly by providing a faster charging and discharging process