Martina Litschmannová

Dr. Martina Litschmannová

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2018 in Journal of Anesthesia
Verified
Journal Article
Closed access
PDF file
OJOndřej Jor
Ondřej Jor
JMJan Máca
Jan Máca
JKJirina Koutna
Jirina Koutna
MGMichaela Gemrotova
Michaela Gemrotova
TVTomas Vymazal
Tomas Vymazal
VCVladimir Cerny
Vladimir Cerny

11 September 2012 in Journal of Sports Sciences
Verified
Journal Article
Closed access
LCLukas Cipryan
Lukas Cipryan
MLMartina Litschmannová
Martina Litschmannová
At present, analysis of heart rate variability (HRV) is becoming widely used as a clinical or research tool. Supported reliability studies for HRV measurement are, however, still limited. The main purpose was to perform an assessment of the absolute and relative reliability of HRV parameters from short-term recordings by means of orthoclinostatic stimulation and to investigate, whether there is a difference in repeating the retest immediately or after several days. The study group consisted of 99 participants (mean age 22 ± 1.24 years). Standard HRV indexes were computed: PT (total spectral power), PHF (high frequency spectral power), PLF (low frequency spectral power) and LF/HF. Absolute reliability was assessed by the standard error of measurement and 95% limits of agreement; relative reliability was assessed by the intraclass correlation coefficient. There was also an estimate of the sample size needed to detect the mean difference ≥ 30% of the between-subject standard deviation. In conclusion, a large random variation (within individuals) of HRV parameters was revealed, regardless of whether the retest was repeated immediately or with an interruption. For most HRV parameters (particularly in the immediately repeated test-retest), however, random variation represents a limited portion of the between-subject variability.

6 June 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RJRene Jaros
Rene Jaros
KBKaterina Barnova
Katerina Barnova
RKRadana Vilimkova Kahankova
Radana Vilimkova Kahankova
JPJan Pelisek
Jan Pelisek
MLMartina Litschmannová
Martina Litschmannová
Radek MartinekRadek Martinek
Radek Martinek
The independent component analysis (ICA) based methods are among the most prevalent techniques used for non-invasive fetal electrocardiogram (NI-fECG) processing. Often, these methods are combined with other methods, such adaptive algorithms. However, there are many variants of the ICA methods and it is not clear which one is the most suitable for this task. The goal of this study is to test and objectively evaluate 11 variants of ICA methods combined with an adaptive fast transversal filter (FTF) for the purpose of extracting the NI-fECG. The methods were tested on two datasets, Labour dataset and Pregnancy dataset, which contained real records obtained during clinical practice. The efficiency of the methods was evaluated from the perspective of determining the accuracy of detection of QRS complexes through the parameters of accuracy (ACC), sensitivity (SE), positive predictive value (PPV), and harmonic mean between SE and PPV (F1). The best results were achieved with a combination of FastICA and FTF, which yielded mean values of ACC = 83.72%, SE = 92.13%, PPV = 90.16%, and F1 = 91.14%. Time of calculation was also taken into consideration in the methods. Although FastICA was ranked to be the sixth fastest with its mean computation time of 0.452 s, it had the best ratio of performance and speed. The combination of FastICA and adaptive FTF filter turned out to be very promising. In addition, such device would require signals acquired from the abdominal area only; no need to acquire reference signal from the mother’s chest.

1 January 2015 in Neural Network World
Verified
Journal Article
Closed access
MGMartin Golasowski
Martin Golasowski
MLMartina Litschmannová
Martina Litschmannová
ŠKŠtěpán Kuchař
Štěpán Kuchař
MPMichal Podhoranyi
Michal Podhoranyi
JMJan Martinovic
Jan Martinovic

19 August 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KBKaterina Barnova
Katerina Barnova
RKRadana Kahankova
Radana Kahankova
RJRene Jaros
Rene Jaros
MLMartina Litschmannová
Martina Litschmannová
Radek MartinekRadek Martinek
Radek Martinek
Fetal phonocardiography is a non-invasive, completely passive and low-cost method based on sensing acoustic signals from the maternal abdomen. However, different types of interference are sensed along with the desired fetal phonocardiography. This study focuses on the comparison of fetal phonocardiography filtering using eight algorithms: Savitzky-Golay filter, finite impulse response filter, adaptive wavelet transform, maximal overlap discrete wavelet transform, variational mode decomposition, empirical mode decomposition, ensemble empirical mode decomposition, and complete ensemble empirical mode decomposition with adaptive noise. The effectiveness of those methods was tested on four types of interference (maternal sounds, movement artifacts, Gaussian noise, and ambient noise) and eleven combinations of these disturbances. The dataset was created using two synthetic records r01 and r02, where the record r02 was loaded with higher levels of interference than the record r01. The evaluation was performed using the objective parameters such as accuracy of the detection of S1 and S2 sounds, signal-to-noise ratio improvement, and mean error of heart interval measurement. According to all parameters, the best results were achieved using the complete ensemble empirical mode decomposition with adaptive noise method with average values of accuracy = 91.53% in the detection of S1 and accuracy = 68.89% in the detection of S2. The average value of signal-to-noise ratio improvement achieved by complete ensemble empirical mode decomposition with adaptive noise method was 9.75 dB and the average value of the mean error of heart interval measurement was 3.27 ms.

1 July 2014 in Journal of Human Sport and Exercise
Verified
Journal Article
Open access
LCLukas Cipryan
Lukas Cipryan
MLMartina Litschmannová
Martina Litschmannová
Intra-session stability of short-term heart rate variability measurement: gender and total spectral power influence