Sławomir Zator

Prof. Dr. Sławomir Zator

Opole University of Technology, Opole, Opolskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in International Journal of Critical Infrastructure Protection
Verified
Journal Article
Closed access
Michał TomaszewskiMichał Tomaszewski
Michał Tomaszewski
BRBogdan Ruszczak
Bogdan Ruszczak
PMPaweł Michalski
Paweł Michalski
Sławomir ZatorSławomir Zator
Sławomir Zator

20 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
Sławomir ZatorSławomir Zator
Sławomir Zator
WSWaldemar Skomudek
Waldemar Skomudek
This article presents a case study of a single-family house, whose current energy source is electricity only. Nine years ago, the heat source for the heating system and domestic hot water was an oil boiler, which was changed to an air–water heat pump. Four years ago, when Poland formed the basis of the prosumer market, the first photovoltaic system was established. It was expanded in the following years. In this work are presented the impact of using a heat accumulator on the coefficient of performance of the heat pump, the self-consumption of energy from the photovoltaic system, and the cost of purchasing energy. Comparative calculations were made, with the demand-side management (DSM) active on work days, and on free days (weekends and public holidays) it was not. Attention was paid to the self-consumption factor depending on the algorithms used in an energy meter. The prosumer market in Poland was also described. The calculations described the house as having an annual energy self-consumption from photovoltaic about 6% higher than average values obtained in buildings with heat pumps. Simultaneously, due to energy storage in heat and the load shifting in the multi-zone tariff, the cost of purchasing energy was 47% lower than in a single-zone tariff (without heat storage and load shifting).

13 September 2019 in IET Image Processing
Verified
Journal Article
Open access
PDF file
MTMichał Tomaszewski
Michał Tomaszewski
PMPaweł Michalski
Paweł Michalski
BRBogdan Ruszczak
Bogdan Ruszczak
Sławomir ZatorSławomir Zator
Sławomir Zator
The massive growth of technologies used to register and process digital images allow for their application in evaluating the technical condition of power lines. However, it is not possible without a set of dedicated methods for obtaining diagnostic information based on registered video data. The method described here details the detection of power line insulators in digital images featuring diversified backgrounds using laser spots. The algorithm of detecting an insulator in analysed images is based on testing the digital signal of pixel intensity profiles read between subsequent pairs of laser points in the image. The method is comprised of the following stages: import the image with laser spots, detection of spots on the image, and pattern classification of each image profile that is calculated for each found laser spots pair. The evaluated profiles depicting an insulator were characterised by regular patterns that reflect the target structure. To classify profiles as either insulator containing or non‐containing, several steps should be followed: averaging the signal, removing the linear trend, finding and alternating the minima and maxima. The performance of the proposed method was verified using an open‐access dataset, comprised of various scenes featuring high‐voltage power line insulators.

19 December 2021 in Energies
Verified
Journal Article
Open access
PDF file
Sławomir ZatorSławomir Zator
Sławomir Zator
This article presents a case study of a single-family house with several photovoltaic micro-installations oriented in different directions, in which the energy electricity storage systems have been operating for several months. In the house, the heat source is the air–water heat pump cooperating with heat buffers. The first photovoltaic installation was installed in 2016 and, in the subsequent five years, was expanded using microinverters. The final amount of energy from photovoltaics covers 50% of the energy demand of the building. The procedure for dealing with technical and economic aspects was presented, allowing us to determine whether it is profitable to install energy storage in the given conditions of energy prices, equipment efficiency, and prices, as well as government support. This paper presents the effects of the designed and built home energy management system that supervises energy storage in heat and batteries, mainly through its impact on the self-consumption of energy from the photovoltaic system and on final costs. Comparative calculations were performed with the demand-side management, which dictated the instantaneous energy costs. Attention was paid to the possibility of obtaining a high self-consumption, but the economic calculations showed that it was not always beneficial. An annual self-consumption increased by approximately one-sixth upon installation of the electrical energy storage system and by one-third from the start of use of the home energy management system. Concurrently, by utilising energy storage in heat and batteries, almost 95% of energy was consumed in the cheapest multi-zone tariff. The impact of inverters and battery charging systems on the power grid is also presented. Often, when the active energy was nearing zero, the capacitive reactive energy was significant.

21 March 2024 in Multimedia Tools and Applications
Verified
Journal Article
Closed access
PDF file
Michał TomaszewskiMichał Tomaszewski
Michał Tomaszewski
Rafal GaszRafal Gasz
Rafal Gasz
Singara Singh KasanaSingara Singh Kasana
Singara Singh Kasana
JOJakub Osuchowski
Jakub Osuchowski
SSSimranjit Singh
Simranjit Singh
Sławomir ZatorSławomir Zator
Sławomir Zator

1 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Sławomir ZatorSławomir Zator
Sławomir Zator
Michał TomaszewskiMichał Tomaszewski
Michał Tomaszewski
Mirosław LasarMirosław Lasar
Mirosław Lasar
Proper maintenance management of power infrastructure requires inspections, in order to gather knowledge about the facility’s current condition. For this purpose, periodic diagnostic tests are carried out, not only to determine the current state, but to also predict future conditions, and subsequently plan for the scope of necessary repair work. Currently, in the case of heat screens of power boilers, the diagnostic process takes many days, is very expensive, and usually does not cover the entire screen area. Therefore, it is necessary to develop new, noninvasive diagnostic methods. This study presents the concept and research for an alternative method of locating places with excessive energy boiler screen degradation that require replacement. It was assumed that the new method should be fast, require no scaffolding assembly, and permit checking of the entire screen surface; this is unlike the methods used currently, which require manual checking of selected screen tubes. The proposed method is based on active thermography, in which heat flux is forced by the liquid flowing inside the screen. Tests were carried out based on a model of an axial-symmetric system in the form of a tube, with controlled reductions in the wall thickness. An experiment was carried out many times by recording the pipe surface temperature in many characteristic places (different thicknesses of the tube walls) with a thermal imaging camera. A temperature change was forced by a controlled flow of hot or cold water. The methods of analysis were proposed and verified, allowing firstly, detection of places with a reduced wall thickness, and secondly, estimations of the wall thickness (i.e., excessive degradation). For the best-proposed model (one of the four analyzed), all of the thickness changes were detected, and the limit error of thickness obtained was 0.3 mm.