Mirosław Lasar

Dr. Mirosław Lasar

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Sławomir ZatorSławomir Zator
Sławomir Zator
Michał TomaszewskiMichał Tomaszewski
Michał Tomaszewski
Mirosław LasarMirosław Lasar
Mirosław Lasar
Proper maintenance management of power infrastructure requires inspections, in order to gather knowledge about the facility’s current condition. For this purpose, periodic diagnostic tests are carried out, not only to determine the current state, but to also predict future conditions, and subsequently plan for the scope of necessary repair work. Currently, in the case of heat screens of power boilers, the diagnostic process takes many days, is very expensive, and usually does not cover the entire screen area. Therefore, it is necessary to develop new, noninvasive diagnostic methods. This study presents the concept and research for an alternative method of locating places with excessive energy boiler screen degradation that require replacement. It was assumed that the new method should be fast, require no scaffolding assembly, and permit checking of the entire screen surface; this is unlike the methods used currently, which require manual checking of selected screen tubes. The proposed method is based on active thermography, in which heat flux is forced by the liquid flowing inside the screen. Tests were carried out based on a model of an axial-symmetric system in the form of a tube, with controlled reductions in the wall thickness. An experiment was carried out many times by recording the pipe surface temperature in many characteristic places (different thicknesses of the tube walls) with a thermal imaging camera. A temperature change was forced by a controlled flow of hot or cold water. The methods of analysis were proposed and verified, allowing firstly, detection of places with a reduced wall thickness, and secondly, estimations of the wall thickness (i.e., excessive degradation). For the best-proposed model (one of the four analyzed), all of the thickness changes were detected, and the limit error of thickness obtained was 0.3 mm.

21 August 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Rafal GaszRafal Gasz
Rafal Gasz
Mirosław LasarMirosław Lasar
Mirosław Lasar
Michał TomaszewskiMichał Tomaszewski
Michał Tomaszewski
Sławomir ZatorSławomir Zator
Sławomir Zator
Power boiler tubes are exposed to severe operating conditions that lead to wall thinning and material degradation. Reliable assessment of tube wall thickness is therefore essential for ensuring safe and efficient boiler operation. This exploratory laboratory study investigates the applicability of active thermography combined with analytical and machine learning (ML) approaches for non-contact wall thickness estimation in power boiler tubes. Experimental investigations were performed on a single boiler tube specimen with artificially introduced wall-thickness reductions. Thermal responses were recorded using an infrared camera under both heating and cooling excitation conditions. Based on the acquired thermographic data, analytical models and machine learning algorithms were developed to estimate tube wall thickness. The machine learning approach was implemented using Random Forest and Support Vector Regression models and compared with conventional analytical modeling techniques. For separately analyzed and relatively homogeneous measurement series, the machine learning models produced lower descriptive errors than the analytical models, with the estimated three-RMSE error envelope decreasing from 0.51 mm to 0.17 mm. However, when heating and cooling datasets were aggregated, the analytical models achieved lower root mean square error values and demonstrated greater stability than the machine learning methods. These findings indicate that model performance strongly depends on the size, characteristics, and homogeneity of the available training data. Owing to the limited number of independent measurement series, the reported results should be interpreted as a small-sample feasibility assessment rather than as evidence of the general superiority of machine learning modeling. The results support the potential of active thermography for non-contact assessment of boiler tube wall thickness under controlled laboratory conditions. Further validation using additional specimens, grouped cross-validation, and physics-based synthetic data is required before the methodology can be considered for industrial implementation.