Ester Vasta

Dr. Ester Vasta

University of Catania - Department of Electrical, Electronic and Computer Engineering
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
EVEster Vasta
Ester Vasta
TStommaso Scimone
tommaso Scimone
GNGiovanni Nobile
Giovanni Nobile
OEOtto Eberhardt
Otto Eberhardt
DDDaniele Dugo
Daniele Dugo
MCMario Cacciato
Mario Cacciato
Considering the importance of lithium-ion (Li-ion) batteries and the attention that the study of their degradation deserves, this work provides a review of the most important battery state of health (SOH) estimation methods. The different approaches proposed in the literature were analyzed, highlighting theoretical aspects, strengths, weaknesses and performance indices. In particular, three main categories were identified: experimental methods that include electrochemical impedance spectroscopy (EIS) and incremental capacity analysis (ICA), model-based methods that exploit equivalent electric circuit models (ECMs) and aging models (AMs) and, finally, data-driven approaches ranging from neural networks (NNs) to support vector regression (SVR). This work aims to depict a complete picture of the available techniques for SOH estimation, comparing the results obtained for different engineering applications.

5 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Giovanni NobileGiovanni Nobile
Giovanni Nobile
MCMario Cacciato
Mario Cacciato
EVEster Vasta
Ester Vasta
The traditional approach to calculate the active and reactive power in AC power systems requires the measurement of the phase shift between the voltage and current for the evaluation of the power factor. To do this, power analyzers can implement several methods. In principle, it is always necessary to identify specific points of waveforms (e.g., using a zero-crossing detection technique) and get their time shift. In a similar way, the frequency value must be evaluated in order to calculate the angular frequency. Unfortunately, this kind of common method exhibits some issues, such as the large sensitivity to noise. Moreover, inaccuracies in the evaluation of the power factor have a big impact on the final estimation of the electric power. This paper presents a simple but effective way to calculate the electric power, overcoming the need for a direct measurement of the phase shift and frequency. In particular, it is shown that the active power can be easily calculated as the difference between the peak value of the instantaneous power and apparent power. The reactive power and power factor are evaluated by exploiting the same quantities. The practical implementation of the proposed formulation in power analyzers guarantees several benefits without reducing accuracy.

1 June 2020
Verified
Conference Paper
Closed access
GNGiovanni Nobile
Giovanni Nobile
EVEster Vasta
Ester Vasta
MCMario Cacciato
Mario Cacciato
GSGiuseppe Scarcella
Giuseppe Scarcella
GSGiacomo Scelba
Giacomo Scelba
FBFabrizio Bizzarri
Fabrizio Bizzarri
The mismatch effect is of fundamental importance in the operation of photovoltaic (PV) power plants because it causes significant losses in energy production. Mismatch originates from several factors such as non-uniform modules aging, shading, dust accumulation, faults in tracker systems and so on. Evaluation of mismatch level is a difficult task because it is necessary to take into account many factors: power configuration, geographical position, weather conditions, quality of measurements provided by dataloggers, etc. Moreover, since different criteria can be applied to calculate the percentage of mismatch, different results might be obtained for the same PV system leading in some cases to wrong conclusions. With the purpose of introducing some approaches for the assessment of mismatch losses in large PV fields, this paper presents a study carried out from data acquired in an existing 300 MW PV plant in Brazil in which an experimental 2.5 MW subfield was realized using 60 kW string inverters whose input stage has more DC/DC input converters. This particular power configuration allows the calculation of mismatch at string level as well as at array level at the DC side input of each string inverter. A multi-criteria approach has been implemented with the purpose to evaluate the coherency of results. A modelling strategy, based on an integrated state-space average model, has been exploited in order to get all the electrical quantities in case of faults, missing or wrong measurements.

1 September 2019
Verified
Conference Paper
Closed access
GNG. Nobile
G. Nobile
MCM. Cacciato
M. Cacciato
GSG. Scarcella
G. Scarcella
Giacomo ScelbaGiacomo Scelba
Giacomo Scelba
EVEster Vasta
Ester Vasta
FBF. Bizzarri
F. Bizzarri

13 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
Giovanni NobileGiovanni Nobile
Giovanni Nobile
EVEster Vasta
Ester Vasta
MCMario Cacciato
Mario Cacciato
GSGiuseppe Scarcella
Giuseppe Scarcella
Giacomo ScelbaGiacomo Scelba
Giacomo Scelba
FBFabrizio Bizzarri
Fabrizio Bizzarri
Distributed power converters represent a technical solution to improve the performance of large or utility-scale photovoltaic (PV) plants. Unfortunately, evaluation of the yield obtained in large PV fields by using distributed converters is a difficult task because of recurring partial unavailability, inaccuracy of power analyzers, operating constraints imposed by the Power Plant Controller and so on. To overcome such issues in real operating scenarios, a new modeling strategy has been introduced and validated in terms of computational complexity and accuracy. This approach is based on the state-space averaging technique which is applied to large PV plants with multiple conversion stages by performing some elaborations in order to get a final integrated model. The new modeling strategy has been tested in MatLab Simulink environment using data coming from a 300 MW PV plant located in Brazil representing the case study of this work. In this plant, one subfield is equipped with central inverters while another is with string inverters. The proposed model, whose accuracy is in the range from 2.2 to 2.7% with respect to the measured energy, effectively supports data analysis leading to a consistent performance assessment for the distributed conversion system. Final results highlight that string inverters ensure a gain of about 2% in terms of produced energy.

26 April 2020
Verified
Book Chapter
Closed access
PDF file
Giovanni NobileGiovanni Nobile
Giovanni Nobile
MCMario Cacciato
Mario Cacciato
GSGiuseppe Scarcella
Giuseppe Scarcella
GSGiacomo Scelba
Giacomo Scelba
EVEster Vasta
Ester Vasta
FBFabrizio Bizzarri
Fabrizio Bizzarri