Background: Percutaneous coronary intervention (PCI) represents an important alternative to coronary bypass surgery for the treatment of patients with complex coronary artery disease and high perioperative risk. Protected percutaneous coronary intervention applies temporary percutaneous ventricular assist devices to mitigate potential hemodynamic compromise in high-risk patients. The Impella system is currently the most commonly used device for protected percutaneous coronary intervention and showed improved hemodynamic parameters in earlier trials. Methods: This study was designed as a retrospective, observational multi-center registry conducted in ten hospitals in Germany. We included consecutive patients undergoing protected high-risk percutaneous coronary intervention with Impella support. The primary endpoint was defined as the occurrence of a major adverse cardiac event defined as all-cause mortality, ST-elevation myocardial infarction, or stroke during a postprocedural 180-day follow-up period. Results: In total, 157 patients (80.3% male; mean age 71.8 ± 10.8 years) were included in the present study, and 180-day follow-up was complete for 149 patients (94.9%). At baseline, the patients had a median left ventricular ejection fraction of 39.0% (interquartile range, 25.0–50.0%). The median SYNergy between PCI with TAXUS and Cardiac Surgery-Score I was 33.0 (interquartile range, 24.0–40.5) and the median EuroSCORE II was 7.2% (interquartile range, 3.2-17.1%). During postprocedural follow-up, 34 patients (22.8%) suffered a major adverse cardiac event. All-cause mortality was 18.1% (27 patients). Nine patients (6.0%) sustained a ST-elevation myocardial infarction, while 4 patients (2.7%) had a stroke. Conclusions: Patients undergoing protected high-risk percutaneous coronary intervention with Impella support showed an acceptable 180-day clinical outcome regarding major adverse cardiac event and mortality.
Background: Parameters that mark the timing of left ventricular (LV) reverse remodeling following transcatheter aortic valve replacement (TAVR) are incompletely defined. This study aims to identify the dynamics of LV strain derived from speckle tracking echocardiography in a cohort of patients with severe aortic stenosis (AS) who underwent TAVR and its correlation with postprocedural outcomes. Methods: We selected 150 consecutive patients (82 ± 4 years old, STS score 6.4 ± 6.2) who underwent transfemoral TAVR between 07/2016 and 12/2017 at our tertiary care center. All patients were evaluated at baseline, 1 week after TAVR, and 3 months following TAVR. Results: The global longitudinal strain (GLS) 1 week following TAVR was comparable to that at baseline (− 15,9 ± 4.3 vs − 16.8 ± 4.1; p = NS) but significantly improved at 3 months following TAVR (− 15.9 ± 4.3% vs. -19.5 ± 3.5%; p < 0.001). No significant changes in global circumferential strain (GCS) and global radial strain (GRS) were detectable. The ejection fraction was significantly improved 1 week after the TAVR procedure. The baseline GLS correlated directly with the complication rate (R = 0.36, p = 0.005). The linear regression analysis showed that the main predictors of the improvement in the GLS at 3 months in our cohort were baseline GRS and GCS. Conclusion: GLS improves at 3 months after TAVR, while LV ejection fraction does not show a substantial change, signaling an early recovery of LV longitudinal function after the intervention. Additionally, GLS has a direct correlation with the postprocedural outcomes. GLS improvement might emerge as a valuable parameter for a tailored follow-up in TAVR patients.
Objectives: Liver transplantation (LT) is associated with high stress on the cardiovascular system. Ruling out coronary artery disease (CAD) is an important part of evaluation for LT. The aim of our study was to assess whether CT-derived fractional flow reserve (CT-FFR) allows for differentiation of hemodynamically significant and non-significant coronary stenosis in patients evaluated for LT. Methods: In total, 201 patients undergoing LT evaluation were included in the study. The patients received coronary computed tomography angiography (CCTA) to rule out CAD and invasive coronary angiography (ICA) to further evaluate coronary lesions found in CCTA if a significant (≥ 50 % on CCTA) stenosis was suspected. CT-FFR was computed from CCTA datasets using a machine learning–based algorithm and compared to ICA as a standard of reference. Coronary lesions with CT-FFR ≤ 0.80 were defined as hemodynamically significant. Results: In 127 of 201 patients (63%), an obstructive CAD was ruled out by CCTA. In the remaining 74 patients (37%), at least one significant stenosis was suspected in CCTA. Compared to ICA, sensitivity, specificity, PPV, and NPV of the CT-FFR measurements were 71% (49–92%), 90% (82–98%), 67% (45–88%), and 91% (84–99%), respectively. The diagnostic accuracy was 85% (85–86%). In 69% of cases (52 of 75 lesions), additional analysis by CT-FFR correctly excluded the hemodynamic significance of the stenosis. Conclusions: Machine learning–based CT-FFR seems to be a very promising noninvasive approach for exclusion of hemodynamic significant coronary stenoses in patients undergoing evaluation for LT and could help to reduce the rate of invasive coronary angiography in this high-risk population. Key Points: • Machine learning–based computed tomography-derived fractional flow reserve (CT-FFR) seems to be a very promising noninvasive approach for exclusion of hemodynamic significance of coronary stenoses in patients undergoing evaluation for liver transplantation and could help to reduce the rate of invasive coronary angiography in this high-risk population.
Mechanical circulatory support (MCS) devices are increasingly used to provide hemodynamic stability for patients with severe coronary artery disease, comorbidities, and/or impaired hemodynamics during high-risk percutaneous coronary interventions (PCI). Vascular access site complications, particularly those due to the use of large-bore sheaths, may limit outcomes in these patients. The aim of this study was to investigate the incidence and predictors of vascular complications in protected high-risk PCIs. Therefore, we included patients undergoing high-risk PCI with an Impella device from January 2016 to August 2018. Vascular complications were graded according to ‘Valve Academic Research Consortium-2’, a definition routinely used in transcatheter valve implantation procedures. In total, 61 patients (mean age 72 ± 11 years, 79% male, SYNTAX score 33 ± 7) were included, and angiographic- and fluoroscopic-guided vascular access was used for Impella implantation in all patients. Major vascular complications occurred in 5 male patients (8%). All major vascular complications were treated conservatively without the need for surgical intervention, and only one patient received a transfusion of three erythrocyte concentrates. Regression analysis revealed that patients with peripheral arterial disease of the lower extremities are at higher risk of major vascular complications. In conclusion, the utilization of Impella using a standardized protocol for angiographic- and fluoroscopic-guided vascular access was associated with a low rate of vascular complications.
Transcatheter aortic valve implantation (TAVI) has evolved to a treatment of choice in high-risk patients and is therefore ideal for patients with advanced chronic kidney disease, as patients with end-stage renal disease and kidney transplant recipients. Especially, outcome of this special patient group is very important. 22 patients with chronic kidney disease stage 5 undergoing intermittent hemodialysis treatment (CKD 5D) and 8 kidney transplant recipients (KT) with severe aortic valve stenosis underwent transfemoral TAVI. TAVI was successfully performed in all patients. Postinterventional acute kidney injury (AKI) occurred in four kidney transplant recipients (KDIGO grade 1: n = 3, grade 3: n = 1) but creatinine/eGFR returned to baseline values in all patients. Short-term (30-day) mortality was 3% (1 patient in CKD 5D group). KT had a higher 2-year mortality than CKD5D patients (31% vs. 53%; p = 0.309), and cause of death was non-cardiac because of sepsis in all cases. The amount of contrast medium during TAVI was not associated with the development of acute kidney injury. TAVI is feasible in patients with CKD5D and in KT. Postinterventional AKI in these patients is often mild and does not impact renal function at day 30, while infection/ sepsis is the leading cause of mid-term mortality.
1 March 2017 in International Journal of Cardiology