Pamela Bhatti

Dr. Pamela Bhatti


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2021 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
SGShambavi Ganesh
Shambavi Ganesh
PBPamela Bhatti
Pamela Bhatti
MAMhmtjamil Alkhalaf
Mhmtjamil Alkhalaf
SGShishir Gupta
Shishir Gupta
ASAmit J. Shah
Amit J. Shah
STSrini Tridandapani
Srini Tridandapani
Objective: We propose a MATLAB-based tool to convert electrocardiography (ECG) waveforms from paper-based ECG records into digitized ECG signals that is vendor-agnostic. The tool is packaged as an open source standalone graphical user interface (GUI) based application. Methods and procedures: To reach this objective we: (1) preprocess the ECG records, which includes skew correction, background grid removal and linear filtering; (2) segment ECG signals using Connected Components Analysis (CCA); (3) implement Optical Character Recognition (OCR) for removal of overlapping ECG lead characters and for interfacing of patients’ demographic information with their research records or their electronic medical record (EMR). The ECG digitization results are validated through a reader study where clinically salient features, such as intervals of QRST complex, between the paper ECG records and the digitized ECG records are compared. Results: Comparison of clinically important features between the paper-based ECG records and the digitized ECG signals, reveals intra- and inter-observer correlations of 0.86–0.99 and 0.79–0.94, respectively. The kappa statistic was found to average at 0.86 and 0.72 for intra- and inter-observer correlations, respectively. Conclusion: The clinically salient features of the ECG waveforms such as the intervals of QRST complex, are preserved during the digitization procedure. Clinical and Healthcare Impact: This open-source digitization tool can be used as a research resource to digitize paper ECG records thereby enabling development of new prediction algorithms to risk stratify individuals with cardiovascular disease, and/or allow for development of ECG-based cardiovascular diagnoses relying upon automated digital algorithms.

8 October 2018 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
JYJingting Yao
Jingting Yao
STS. Tridandapani
S. Tridandapani
WAW. F. Auffermann
W. F. Auffermann
CWC. A. Wick
C. A. Wick
PBPamela Bhatti
Pamela Bhatti
To more accurately trigger data acquisition and reduce radiation exposure of coronary computed tomography angiography (CCTA), a multimodal framework utilizing both electrocardiography (ECG) and seismocardiography (SCG) for CCTA prospective gating is presented. Relying upon a three-layer artificial neural network that adaptively fuses individual ECGand SCG-based quiescence predictions on a beat-by-beat basis, this framework yields a personalized quiescence prediction for each cardiac cycle. This framework was tested on seven healthy subjects (age: 22-48; m/f: 4/3) and eleven cardiac patients (age: 31-78; m/f: 6/5). Seventeen out of 18 benefited from the fusion-based prediction as compared to the ECG-only-based prediction, the traditional prospective gating method. Only one patient whose SCG was compromised by noise was more suitable for ECG-only-based prediction. On average, our fused ECGSCG-based method improves cardiac quiescence prediction by 47% over ECG-only-based method; with both compared against the gold standard, B-mode echocardiography. Fusion-based prediction is also more resistant to heart rate variability than ECG-onlyor SCG-only-based prediction. To assess the clinical value, the diagnostic quality of the CCTA reconstructed volumes from the quiescence derived from ECG-, SCGand fusion-based predictions were graded by a board-certified radiologist using a Likert response format. Grading results indicated the fusion-based prediction improved diagnostic quality. ECG may be a sub-optimal modality for quiescence prediction and can be enhanced by the multimodal framework. The combination of ECG and SCG signals for quiescence prediction bears promise for a more personalized and reliable approach than ECG-only-based method to predict cardiac quiescence for prospective CCTA gating.

7 July 2017 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
JYJingting Yao
Jingting Yao
STSrini Tridandapani
Srini Tridandapani
CWCarson A. Wick
Carson A. Wick
PBPamela Bhatti
Pamela Bhatti
To more accurately trigger cardiac computed tomography angiography (CTA) than electrocardiography (ECG) alone, a sub-system is proposed as an intermediate step toward fusing ECG with seismocardiography (SCG). Accurate prediction of quiescent phases is crucial to prospectively gating CTA, which is susceptible to cardiac motion and, thus, can affect the diagnostic quality of images. The key innovation of this sub-system is that it identifies the SCG waveform corresponding to heart sounds and determines their phases within the cardiac cycles. Furthermore, this relationship is modeled as a linear function with respect to heart rate. For this paper, B-mode echocardiography is used as the gold standard for identifying the quiescent phases. We analyzed synchronous ECG, SCG, and echocardiography data acquired from seven healthy subjects (mean age: 31; age range: 22-48; males: 4) and 11 cardiac patients (mean age: 56; age range: 31-78; males: 6). On average, the proposed algorithm was able to successfully identify 79% of the SCG waveforms in systole and 68% in diastole. The simulated results show that SCG-based prediction produced less average phase error than that of ECG. It was found that the accuracy of ECG-based gating is more susceptible to increases in heart rate variability, while SCG-based gating is susceptible to high cycle to cycle variability in morphology. This pilot work of prediction using SCG waveforms enriches the framework of a comprehensive system with multiple modalities that could potentially, in real time, improve the image quality of CTA.

14 February 2013 in Journal of Digital Imaging
Verified
Journal Article
Open access
PDF file
SRSenthil Ramamurthy
Senthil Ramamurthy
PBPamela Bhatti
Pamela Bhatti
CAChesnal D. Arepalli
Chesnal D. Arepalli
MSMohamed Salama
Mohamed Salama
JPJames M. Provenzale
James M. Provenzale
STSrini Tridandapani
Srini Tridandapani
We introduce the concept, benefits, and general architecture for acquiring, storing, and displaying digital photographs along with medical imaging examinations. We also discuss a specific implementation built around an Android-based system for simultaneously acquiring digital photographs along with portable radiographs. By an innovative application of radiofrequency identification technology to radiographic cassettes, the system is able to maintain a tight relationship between these photographs and the radiographs within the picture archiving and communications system (PACS) environment. We provide a cost analysis demonstrating the economic feasibility of this technology. Since our architecture naturally integrates with patient identification methods, we also address patient privacy issues.

26 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
RSRessa Reneth Sarreal
Ressa Reneth Sarreal
PBPamela Bhatti
Pamela Bhatti
According to the National Institute of Deafness and other Communication Disorders 2012 report, the number of cochlear implant (CI) users is steadily increasing from 324,000 CI users worldwide. The cochlea, located in the inner ear, is a snail-like structure that exhibits a tonotopic geometry where acoustic waves are filtered spatially according to frequency. Throughout the cochlea, there exist hair cells that transduce sensed acoustic waves into an electrical signal that is carried by the auditory nerve to ultimately reach the auditory cortex of the brain. A cochlear implant bridges the gap if non-functional hair cells are present. Conventional CIs directly inject an electrical current into surrounding tissue via an implanted electrode array and exploit the frequency-to-place mapping of the cochlea. However, the current is dispersed in perilymph, a conductive bodily fluid within the cochlea, causing a spread of excitation. Magnetic fields are more impervious to the effects of the cochlear environment due to the material properties of perilymph and surrounding tissue, demonstrating potential to improve precision. As an alternative to conventional CI electrodes, the development and miniaturization of microcoils intended for micromagnetic stimulation of intracochlear neural elements is described. As a step toward realizing a microcoil array sized for cochlear implantation, human-sized coils were prototyped via aerosol jet printing. The batch reproducible aerosol jet printed microcoils have a diameter of 1800 μm, trace width and trace spacing of 112.5 μm, 12 μm thickness, and inductance values of approximately 15.5 nH. Modelling results indicate that the coils have a combined depolarization–hyperpolarization region that spans 1.5 mm and produce a more restrictive spread of activation when compared with conventional CI.

1 November 2021 in Journal of Medical Imaging and Radiation Sciences
Verified
Journal Article
Closed access
STSrini Tridandapani
Srini Tridandapani
SBSwati Banait-Deshmane
Swati Banait-Deshmane
MAMuhammad Usman Aziz
Muhammad Usman Aziz
PBPamela Bhatti
Pamela Bhatti
SSSatinder P. Singh
Satinder P. Singh